Back to Federal guidance

Guarding access openings to fixed ladders

Summary OSHA instructed regional administrators to cite unguarded ladderway floor openings under the then-current §1910.23(a)(2). In its 2009 reading, a platform entrance to a fixed ladder still needed a swinging gate or an offset that kept people from walking directly into the opening, even though a separate provision excepted fixed-ladder entrances from a standard railing.
Document
Federal guidance
Agency
Occupational Safety and Health Administration (OSHA)
Document number
2009-09-29
Date issued
September 29, 2009
Status
Unknown
This enforcement memorandum interprets the fixed-ladder and platform provisions as worded in 2009; current application has not been confirmed.
Status last verified October 8, 2026

Apply this to your situation

This page explains the general guidance. Ask about your specific situation and see what current federal labor law says, with citations.

The current status of this document is unclear
This enforcement memorandum interprets the fixed-ladder and platform provisions as worded in 2009; current application has not been confirmed. It may no longer reflect the agency's current position. Treat this page as historical context, not current guidance, and verify current law before relying on anything here.
About this page: The full text below is the official document from Occupational Safety and Health Administration (OSHA). Ezel adds the plain-English summary and tracks the document's status. The official source linked on this page is authoritative for any reliance.

September 29, 2009

MEMORANDUM FOR:
REGIONAL ADMINISTRATORS
FROM:
RICHARD E. FAIRFAX, DIRECTOR

DIRECTORATE OF ENFORCEMENT PROGRAMS
SUBJECT:
Guarding of Access Openings to Fixed Ladders

The purpose of this memorandum is to clarify the requirements for guarding access openings to fixed ladders. Differences in the regulatory text between paragraphs 1910.23(a)(2) and 1910.23(c)(1) and silence on this issue in paragraph 1910.23(c)(2) and in the fixed ladder standard at 1910.27 have led to some confusion.

Openings on platforms are regulated by different paragraphs of §1910.23. Paragraph §1910.23(a) covers floor openings, including access openings at the edge of a platform. Paragraph §1910.23(b) covers wall openings and wall holes. Paragraph §1910.23(c) covers the edges of open-sided floors and platforms, but not the access openings at the edge of the platform or through the floor.

The governing requirement for the guarding of ladderway floor openings and platforms is paragraph 1910.23(a)(2):

Every ladderway floor opening or platform shall be guarded by a standard railing with standard toeboard on all exposed sides (except at entrance to opening), with the passage through the railing either provided with a swinging gate or so offset that a person cannot walk directly into the opening.

This paragraph applies to ladders that extend to another working surface, even if the ladder attaches to the edge of the working surface or the platform, since the opening at the ladder access point is also a floor opening. It also applies to floor openings in runways and catwalks. All ladderway floor openings or platforms must be protected by a standard railing except at the entrance to the opening. The passage through the railing, however, must be protected by a swinging gate or offset so that a person cannot walk directly into the opening.

Paragraph §1910.23(c)(1) requires a standard railing on all open-sided floors or platforms 4 feet or more above floor or ground level, except at entrances to ramps, stairways, or fixed ladders. It describes where a standard railing is required and includes an exception for the entrance to fixed ladders. This paragraph does not, however, exempt the passage through the railing for platforms from being protected by a gate or offset as required in paragraph 1910.23(a)(2). The intent of the exemption in paragraph (c) was to allow other than a standard, fixed, guardrail at the entrance to a fixed ladder. Required protection for the access openings on runways and catwalks are also included in this paragraph.

Unguarded ladderway floor openings and unguarded ladderway entrances on all surfaces should be cited under section 1910.23(a)(2).

If you need any additional information or clarification on this memorandum, please contact the Office of General Industry Enforcement at (202) 693-1850.

What does federal law require in your situation?

Ezel checks current federal labor law against your facts and answers with citations.

Opens in Ezel Pro.

  • Checks the law as it stands today, not only this page
  • Cites every source it relies on, so you can verify it
  • Chat, drafting and research in one workspace