Archived stair-rail and handrail height interpretation

Summary A requester asked whether a 42-inch stair rail could also serve as a handrail under the then-current general industry rule. OSHA described the old height limits and a de minimis enforcement approach tied to proposed revisions. OSHA marks this letter corrected March 25, 2009 and archived, so its historical measurements should not be read as current policy.
Document
Federal opinion letter
Agency
Occupational Safety and Health Administration (OSHA)
Document number
2005-09-14-0
Date issued
September 14, 2005
Status
Archived by the agency
OSHA archive notice: "This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only." OSHA marks the text corrected March 25, 2009.
Status last verified October 8, 2026

Apply this to your situation

This page explains the general guidance. Ask about your specific situation and see what current federal labor law says, with citations.

The current status of this document is unclear
OSHA archive notice: "This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only." OSHA marks the text corrected March 25, 2009. It may no longer reflect the agency's current position. Treat this page as historical context, not current guidance, and verify current law before relying on anything here.
About this page: The full text below is the official document from Occupational Safety and Health Administration (OSHA). Ezel adds the plain-English summary and tracks the document's status. The official source linked on this page is authoritative for any reliance.

September 14, 2005

Mr. Helmut Haydll

[Recipient address omitted]

Dear Mr. Haydll:

Thank you for your June 24, 2004 letter to the Occupational Safety and Health Administration (OSHA). Your letter was forwarded to the Office of General Industry Enforcement for response. This letter constitutes OSHA's interpretation only of the requirements discussed and may not be applicable to any questions not delineated within your original correspondence. You had specific questions regarding the requirements for stair and hand rails.

The question below has been restated for clarity.

Question: Does the OSHA requirement for a "standard railing" at 42-inch height apply to open stairs? Under the General Industry standard, can a 42-inch high top rail for a stairway also serve as a handrail, or must a handrail also be provided?

Response: In your letter you asked whether the 42-inch height requirement for a "standard railing" (29 CFR 1910.23(e)(1)) applies to open stairs. The requirements for a "stair railing" are set out in 29 CFR 1910.23(e)(2). The vertical height of a stair railing must be not more than 34 inches nor less than 30 inches from the upper surface of the top rail to the surface of the tread. The same height specifications apply to handrails on stairs. See §1910.23(e)(5)(ii).

OSHA, however, opened a rulemaking proceeding in 1990 to revise Subpart D of Part 1910, including the current height requirements for stair railings and handrails. See 55 Federal Register 13396 (April 10, 1990). Under the proposal [proposed §1910.28(c)(2)(ii) and (iv)], for new installation the height of a handrail shall be not less than 36 inches above the tread.

Under the proposal [proposed §1910.28(c)(2)(iv)], a stair rail may also serve as a handrail if its height is not more than 37 inches nor less than 36 inches. In recognition of the fact some existing handrails are set at heights above 34 inches (see 55 Federal Register 13374), the proposal included grandfathering provisions, under which existing handrails would be acceptable if not more than 42 inches nor less than 30 inches above the tread, and an existing stair rail could also serve as a handrail if its height is not more than 42 inches nor less than 36 inches above the tread.

OSHA often treats an employer's compliance with a proposed standard as a de minimis violation of the terms of an existing standard. A de minimis violation results in no citation or abatement requirement. Under this policy for de minimis violations, OSHA will, for stair rails installed prior to the date of the rulemaking notice, allow a stair rail not more than 42 inches nor less than 36 inches above the tread to also serve as a handrail. For installations after the date of the rulemaking notice, the height requirements in the existing standards apply, but a railing/handrail that meets the requirement of the proposed standard will be regarded as a de minimis violation.

Thank you for your interest in occupational safety and health. We hope you find this information helpful. OSHA requirements are set by statute, standards, and regulations. Our interpretation letters explain these requirements and how they apply to particular circumstances, but they cannot create additional employer obligations. This letter constitutes OSHA's interpretation of the requirements discussed. Note that our enforcement guidance may be affected by changes to OSHA rules. Also, from time to time we update our guidance in response to new information. To keep apprised of such developments, you can consult OSHA's website at http://www.osha.gov. If you have any further questions, please feel free to contact the Office of General Industry Enforcement at (202) 693-1850.

Sincerely,

Richard E. Fairfax, Director

Directorate of Enforcement Programs

[Corrected 3/25/2009]