Alternative guardrails instead of perimeter safety cables

Summary A steel erector asked whether wooden or other guardrails can satisfy the perimeter safety cable requirement on multistory structures. OSHA said alternatives can meet the rule when installers have fall protection and the system meets guardrail criteria, is durable, and does not create greater hazards during initial steel connections. The letter addresses the described steel erection work.
Document
Federal opinion letter
Agency
Occupational Safety and Health Administration (OSHA)
Document number
2003-07-21
Date issued
July 21, 2003
Status
Active
Status last verified October 9, 2026

Apply this to your situation

This page explains the general guidance. Ask about your specific situation and see what current federal labor law says, with citations.

About this page: The full text below is the official document from Occupational Safety and Health Administration (OSHA). Ezel adds the plain-English summary and tracks the document's status. The official source linked on this page is authoritative for any reliance.

July 21, 2003

Mr. Jerry Breneman
[Recipient address omitted]

Re: In steel erection, may a guardrail system other than a safety cable be used to meet the requirement for a perimeter safety cable under Part 1926 Subpart R?

Dear Mr. Breneman:

This is in response to your E-correspondence of September 17, 2002, to the Occupational Safety and Health Administration (OSHA). We apologize for the delay in providing a response.

We have paraphrased your question as follows:

Question: The steel erection standard requires perimeter safety cables on multi-story structures. Is it permissible to use other types of guardrail systems (such as wooden guardrails) to meet this requirement?

Answer: Section 1926.760(a)(1) states:

> Except as provided in paragraph (a)(3) of this section, each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6m) above a lower level shall be protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems or fall restraint systems.

Section 1926.760(a)(2) further requires that:

> On multi-story structures, perimeter safety cables shall be installed at the final interior and exterior perimeters of the floors as soon as the metal decking has been installed.

Section 1926.760(a)(2) was promulgated in conjunction with the requirement that perimeter columns have holes or attachments to facilitate the speedy erection of an effective and durable fall protection system. In the preamble to the Final Rule, OSHA explained that the Steel Erection Negotiated Rulemaking Advisory Committee (SENRAC) believed that the relative ease with which safety cables can be erected, especially where columns have pre-installed holes or attachments, presents several safety advantages (66 FR 5228-5229 and 5245, Jan. 18, 2001). Specifically, this system:

  1. Minimizes the exposure of the workers during its erection;
  2. Can be erected as soon as the steel decking has been installed;
  3. Can be engineered to comply with Subpart M; and
  4. Does not create a greater hazard during initial steel erection connection activities.

The use of other types of guardrail systems, such as wooden guardrails, will be considered to meet this requirement where all of the following conditions are met:

  1. the workers installing the system are protected with personal fall arrest equipment or other forms of conventional fall protection;
  2. the system meets the guardrail requirements of §1926.502;
  3. it is durable with respect to exposure to the conditions at the site (such as weather and steel erection activities near to or that may affect the guardrails); and
  4. it does not create a greater hazard during initial steel erection connection activities.

If you would like additional information, please contact us by fax at: U.S. Department of Labor, OSHA, Directorate of Construction, Office of Construction Standards and Compliance Assistance, fax # 202-693-1689. You can also contact us by mail at the above office, Room N3468, 200 Constitution Avenue, N.W., Washington, D.C. 20210, although there will be a delay in our receiving correspondence by mail.

Sincerely,

Russell B. Swanson, Director
Directorate of Construction

What does federal law require in your situation?

Ezel checks current federal labor law against your facts and answers with citations.

Opens in Ezel Pro.

  • Checks the law as it stands today, not only this page
  • Cites every source it relies on, so you can verify it
  • Chat, drafting and research in one workspace