Back to Federal guidance

Air sampling position during welding with respirators

Summary An industrial hygienist asked where to put an air-sampling cassette for welders wearing supplied-air equipment. OSHA said sampling should represent potential exposure in the breathing zone outside the respirator; sampling inside the hood would give an artificially low result. For a welding helmet with no respirator or a negative-pressure respirator, it said to sample inside the helmet.
Document
Federal opinion letter
Agency
Occupational Safety and Health Administration (OSHA)
Document number
1999-02-03
Date issued
February 3, 1999
Status
Active
Status last verified October 9, 2026

Apply this to your situation

This page explains the general guidance. Ask about your specific situation and see what current federal labor law says, with citations.

About this page: The full text below is the official document from Occupational Safety and Health Administration (OSHA). Ezel adds the plain-English summary and tracks the document's status. The official source linked on this page is authoritative for any reliance.

February 3, 1999

Mr. Randy A. Milbrath
HSE Consulting and Sampling
[Recipient address omitted]

Dear Mr. Milbrath:

This is in response to your letter dated November 3, 1998, addressed to the Occupational Safety and Health Administration's (OSHA's) Directorate of Compliance Programs (DCP), regarding the proper air sampling methodology for welding operations. In your letter you have asked for a formal response regarding the correct placement of an air sampling cassette on employees performing welding operations while wearing a supplied air breathing ensemble.

The correct placement for air sampling cassettes is near the breathing zone of the employee. It should be as close as possible to the nose and mouth of the employee, i.e., in a hemisphere forward of the shoulders with a radius of 6 to 9 inches. If the employee is wearing a welding helmet and either no respirator or a negative pressure respirator, sampling should be done inside the helmet.

Since we are concerned with what an employee's potential exposure would be, sampling must always be located outside of any respiratory protective equipment. Sampling inside the ensemble that you have described would be measuring an unrepresentative atmosphere composed of a mixture of the air passing out of the respirator hood and the air outside the hood. This area would be an artificially low concentration. Therefore, sampling should be done as normally would be done for any other contaminant (i.e., in the breathing zone outside the ensemble).

I hope this answers any questions you have on OSHA's sampling policy for welding fumes. If you have any further questions, you may contact OSHA's Office of Health Compliance Assistance at (202) 693-2190.

Sincerely,

Richard E. Fairfax
Director
Directorate of Compliance Programs

What does federal law require in your situation?

Ezel checks current federal labor law against your facts and answers with citations.

Opens in Ezel Pro.

  • Checks the law as it stands today, not only this page
  • Cites every source it relies on, so you can verify it
  • Chat, drafting and research in one workspace