Summary A cleaning contractor asked whether sheetrock and joint compound could be tested as one composite material. OSHA said each must be analyzed separately for asbestos. Where joint compound alone contains more than one percent asbestos, removing the wall panels is Class II work; surfacing asbestos on the panels can change the classification.
Document
Federal opinion letter
Agency
Occupational Safety and Health Administration (OSHA)
Document number
1997-04-28
Date issued
April 28, 1997
Status
Active
Status last verified October 9, 2026

Apply this to your situation

This page explains the general guidance. Ask about your specific situation and see what current federal labor law says, with citations.

About this page: The full text below is the official document from Occupational Safety and Health Administration (OSHA). Ezel adds the plain-English summary and tracks the document's status. The official source linked on this page is authoritative for any reliance.

April 28, 1997
Mr. Gary Thibodeaux
National Service Cleaning Corp.
[Recipient address omitted]
Dear Mr. Thibodeaux:
This is in response to your letter of March 31, concerning sheetrock and joint compound.
You ask whether the Occupational Safety and Health Administration (OSHA) considers sheetrock and joint compound to be a composite material that may be analyzed for asbestos content by collecting composite bulk samples. By interpretation of the definition of asbestos containing material (ACM) presented at 29 CFR 1910.1001(b), [29 CFR 1915.1001], and 29 CFR 1926.1101(b); OSHA regards sheetrock and joint compound as separate materials. Each of these materials that may contain asbestos must be analyzed separately for their asbestos content.
You also asked what class of asbestos work would be involved if the only material containing greater than 1% asbestos is joint compound. We presume you are referring to the removal of interior wall shells constructed with sheetrock panels. If that is the case, the removal operation is Class II asbestos work. OSHA does not consider joint compound to be surfacing material. As indicated on page 41032 of Federal Register, Vol. 59, No. 153, Wednesday, August 10, 1994, joint compound is finishing material. Note that if surfacing material containing more than 1% asbestos was applied to the sheetrock panels, removal of the panels would be considered Class I asbestos work.
We appreciate the opportunity to provide this clarifying information. If you have further questions please contact the [Office of Health Enforcement at (202) 693-2190].
Sincerely,
Stephen Mallinger, Acting Director
[Office of Health Enforcement]
[Corrected 6/2/2005]

------------------------------------------------------------------------

[Requester letter reproduced on OSHA page; omitted here.]

What does federal law require in your situation?

Ezel checks current federal labor law against your facts and answers with citations.

Opens in Ezel Pro.

  • Checks the law as it stands today, not only this page
  • Cites every source it relies on, so you can verify it
  • Chat, drafting and research in one workspace