Lockout of agitators during confined-space cleaning

Summary A dairy association asked whether cleaning vats and tanks with unguarded agitators required lockout or tagout. OSHA said the cleaning was servicing, the spaces had to be isolated, and a starter-switch lock alone generally would not isolate all hazardous energy. OSHA archives the letter and warns it may no longer represent current policy.
Document
Federal opinion letter
Agency
Occupational Safety and Health Administration (OSHA)
Document number
1994-03-03
Date issued
March 3, 1994
Status
Archived by the agency
OSHA labels this an archive document and warns that it may no longer represent current policy.
Status last verified October 9, 2026

Apply this to your situation

This page explains the general guidance. Ask about your specific situation and see what current federal labor law says, with citations.

The current status of this document is unclear
OSHA labels this an archive document and warns that it may no longer represent current policy. It may no longer reflect the agency's current position. Treat this page as historical context, not current guidance, and verify current law before relying on anything here.
About this page: The full text below is the official document from Occupational Safety and Health Administration (OSHA). Ezel adds the plain-English summary and tracks the document's status. The official source linked on this page is authoritative for any reliance.

NOTICE: This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only.

March 3, 1994

Mr. Clay Detlefsen, Assistant Director
Environmental & Workers Safety Issues
International Dairy Foods Association
[Recipient address omitted]
Dear Mr. Detlefsen:

This is in further response to your October 6, 1993 letter, requesting an interpretation of the Control of Hazardous Energy (Lockout/Tagout) standard, 29 CFR 1910.147, with respect to permit space isolation required by 29 CFR 1910.146.

In your letter you referred to a dairy plant's confined space program and cleaning of processing vats and storage tanks. Also, you indicated that the only hazard within these spaces is a low RPM agitator. Apparently, the agitator is unguarded and thereby poses potential employee exposure to hazardous mechanical energy. The permit-required confined space (PRCS or permit space) standard, 29 CFR 1910.146, applies to processing vats and storage tanks which are confined spaces as defined in paragraph (b) and where there is a hazard, including the agitator as described above. Protection of employees against unexpected energization of the agitator is also covered by 1910.147. Under the PRCS program, the permit space must be isolated as required by [1910.146(d)(3)(iii)]. Isolation means the process by which a permit space is removed from service and completely protected against the release of energy... by such means as... lockout or tagout of all sources of energy... As clarified in the 3rd paragraph of the left hand column on page 4497 of the preamble to the Final Rule (a copy of which is enclosed for your use), mechanical equipment, such as an unguarded agitator, posing a hazard within a permit space must be locked out or tagged in accordance with 1910.147.

With respect to 1910.147, the cleaning of dairy plant processing vats and storage tanks is considered to be "servicing and/or maintenance" and not "normal production operations". The control of hazardous energy (lockout/tagout) requirements at 1910.147(c) through (f) apply. Please note that the aforementioned cleaning activities are not considered minor servicing because they do not take place during normal production operations.

As noted previously, the permit space must be isolated by such means as lockout or tagout of all sources of energy. Use of a control switch locking device which locks the agitator starter switch in the off position to isolate control energy may not reliably prevent unexpected start-up and would not isolate transmission (load) energy to the agitator. Not only does the control energy have to be deenergized to prevent unexpected start-up, but also, the transmission (load) energy must be opened and the energy isolation device locked out to prevent unexpected energization. Additionally, although apparently not applicable to deenergizing the agitator, stored (residual) control energy or transmission energy must be relieved, disconnected, restrained and otherwise rendered safe as required by 1910.147(d)(5).

The lockout/tagout standard (1910.147) is intended to protect employees not only from accidents due to equipment malfunctions but also inadvertent or intentional employee acts. For example, an employee may be cleaning a processing vat or storage tank at the same time that an employee is performing servicing and maintenance on the transmission energy part of the agitator's powering system, for example, at the motor control center as discussed in your letter. Lockout of the energy isolating device controlling transmission energy to the agitator would prevent the other employee performing servicing and maintenance from causing unexpected energization of the agitator.

Your letter does not include sufficient information to evaluate whether the control switch locking device, which locks the machine's starter switch in the off position, deenergizes the control energy and prevents start-up by an intentional or unintentional act or by other activation, for example, because of a failure in the control circuitry. Generally speaking, a control switch locking device alone would not meet OSHA's standards as an energy isolating device because unexpected start-up may be the effect of any of the aforementioned causes.

We appreciate your interest in employee safety and health. If we can be of further assistance, please do not hesitate to contact us.

Sincerely,
H. Berrien Zettler, Deputy Director
Directorate of Compliance Programs