Cartridge change intervals for dry cleaning respirators

Summary An OSHA regional office asked how dry cleaners should use air-purifying respirators against perchloroethylene vapors. OSHA said cartridge change intervals must account for the highest expected concentration, and an odor breakthrough requires immediate action rather than serving as the main change schedule. Each shop must determine whether its respirators provide enough protection for its own exposure conditions.
Document
Federal opinion letter
Agency
Occupational Safety and Health Administration (OSHA)
Document number
1990-01-10
Date issued
January 10, 1990
Status
Active
Status last verified October 10, 2026

Apply this to your situation

This page explains the general guidance. Ask about your specific situation and see what current federal labor law says, with citations.

About this page: The full text below is the official document from Occupational Safety and Health Administration (OSHA). Ezel adds the plain-English summary and tracks the document's status. The official source linked on this page is authoritative for any reliance.

January 10, 1990

MEMORANDUM FOR: MICHAEL G CONNORS, REGIONAL ADMINISTRATOR

THROUGH: LEO CAREY, DIRECTOR, OFFICE OF FIELD PROGRAMS

FROM: THOMAS J SHEPICH, DIRECTOR, DIRECTORATE OF COMPLIANCE PROGRAMS

SUBJECT: Use of Air-Purifying Respirators in Dangerous Concentrations of Gases or Vapors

This is in response to your memorandum of September 27, 1989, commenting on the letter dated August 23, 1989, from Acting Assistant Secretary Alan C. McMillan to Duane A. Siler, Counsel for International Fabricare Institute (IFI).
The letter relates that if appropriate procedures are followed, it is acceptable to use air-purifying respirators in the dry cleaning industry for protecting employees from perchloroethylene. The letter then identifies the procedures that must be followed. I will repeat each of them receiving your comments, repeat your comments, and then provide some clarification.
Procedure: The respirator cartridge must be changed periodically to assure that its capacity has not been exceeded.
Your comment: This is difficult to do because concentrations of the chemicals change.
Clarification: Employers must choose intervals between changing cartridges that are short enough so that the cartridge capacity will not be exceeded at the highest air contaminant concentration that occurs. For example, if airborne perchloroethylene concentrations range from 25 to 250 ppm, the employer must choose an interval between changing cartridges that is based on a perchloroethylene concentration of 250 ppm.
Procedure: The filter must be changed immediately if there is evidence of filter breakthrough because the employee detects the odor of perchloroethylene while wearing the respirator.
Your comment: The exposure limit is 25 ppm. The odor threshold is 5 to 75 ppm. Therefore, for some individuals when they notice an odor, they may already be exposed to three times the permissible exposure limit.
Clarification: Periodic changing of respirator cartridges is the basic means of protecting employees. Therefore, filter breakthrough should not occur. However, in an accidental case where it happens, it is important to stress the need for immediate remedial action. Moreover, the permissible exposure limit concentration is an 8-hour time-weighted average value. Therefore, if an employee's odor threshold for perchloroethylene were only 75 ppm, in order for the employee to become overexposured to perchloroethylene before being able to sense that it had broken through the cartridge, more than two hours and forty minutes of time would have to elapse prior to the concentration inside the respirator increasing to 75 ppm.
Procedure: The employer must abide by appropriate respirator protection factors.
Your comment: Unless air samples are taken frequently, the employer does not know the concentration and would not know how much of a protection factor is needed.
Clarification: Your comment applies for any type respirator. One way to reduce the required frequency of sampling is to provide respirators with protection factors high enough for all occasions. For the majority of dry cleaning establishments, there are indications that a protection factor of 10 is high enough for all perchloroethylene exposure situations. Of course, each dry cleaning establishment must make its own determination whether respirators with a protection factor of 10 are adequate for all exposure situations.
Where an inspection reveals inadequacies in the employers cartridge replacement program or in determining the efficacy of a certain respirator type, appropriate violations of [1910.134(c), 1910.134(d), 1910.134(g), 1910.134(h), and 1910.134(k)] shall be considered.
[Corrected 3/23/2009]

What does federal law require in your situation?

Ezel checks current federal labor law against your facts and answers with citations.

Opens in Ezel Pro.

  • Checks the law as it stands today, not only this page
  • Cites every source it relies on, so you can verify it
  • Chat, drafting and research in one workspace