Back to Federal guidance

Tip-up guardrails for roof window cleaners

Summary An engineer asked whether a particular hinged rooftop guardrail could protect window cleaners. OSHA said the described placement appeared to meet the intent of its guardrail rule, provided the completed top rail could withstand a 200-pound load in any direction. OSHA archives the letter.
Document
Federal opinion letter
Agency
Occupational Safety and Health Administration (OSHA)
Document number
1982-02-04
Date issued
February 4, 1982
Status
Archived by the agency
OSHA labels this an archive document and warns that it may no longer represent OSHA policy.
Status last verified October 10, 2026

Apply this to your situation

This page explains the general guidance. Ask about your specific situation and see what current federal labor law says, with citations.

The current status of this document is unclear
OSHA labels this an archive document and warns that it may no longer represent OSHA policy. It may no longer reflect the agency's current position. Treat this page as historical context, not current guidance, and verify current law before relying on anything here.
About this page: The full text below is the official document from Occupational Safety and Health Administration (OSHA). Ezel adds the plain-English summary and tracks the document's status. The official source linked on this page is authoritative for any reliance.

NOTICE: This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only.

February 4, 1982

Lawrence R. Stafford, P.E.
Consulting Engineer
[Recipient address omitted]

Dear Mr. Stafford:

This is in response to the question raised in your letter of January 20, 1982, concerning a tip-up rigid guardrail system.

A tip-up guardrail system 3'-6" high, with the hinged base located approximately six inches inboard from an eight inch high parapet, placing the window cleaner approximately five feet inboard from the roof edge when raising the guardrail sections, appear to comply with the intent of 29 CFR 1910.23(c). However, the anchoring of posts and framing of members for railing of all types must be of such construction that the completed structure will be capable of withstanding a load of at least 200 pounds applied in any direction at any point on the top rail.

If we may be of further assistance, please call or write.

Sincerely,

Patrick R. Tyson
Director,
Federal Compliance and State Programs

What does federal law require in your situation?

Ezel checks current federal labor law against your facts and answers with citations.

Opens in Ezel Pro.

  • Checks the law as it stands today, not only this page
  • Cites every source it relies on, so you can verify it
  • Chat, drafting and research in one workspace