Back to Federal guidance

Steel truss work and perimeter fall protection

Summary A lawyer sought a variance for perimeter netting during steel truss work. OSHA discussed static lines, ladder access, and the limited circumstances in which initial steel connectors might work without fall protection. OSHA later struck one statement on the page as no longer representing policy and directs readers to a later steel erection directive.
Document
Federal opinion letter
Agency
Occupational Safety and Health Administration (OSHA)
Document number
1981-04-17
Date issued
April 17, 1981
Status
Archived by the agency
OSHA labels this an archive document. A June 20, 2005 edit strikes an earlier statement as no longer representing policy and points to OSHA Directive CPL 02-01-034 for current steel erection inspection policy.
Status last verified October 10, 2026

Apply this to your situation

This page explains the general guidance. Ask about your specific situation and see what current federal labor law says, with citations.

The current status of this document is unclear
OSHA labels this an archive document. A June 20, 2005 edit strikes an earlier statement as no longer representing policy and points to OSHA Directive CPL 02-01-034 for current steel erection inspection policy. It may no longer reflect the agency's current position. Treat this page as historical context, not current guidance, and verify current law before relying on anything here.
About this page: The full text below is the official document from Occupational Safety and Health Administration (OSHA). Ezel adds the plain-English summary and tracks the document's status. The official source linked on this page is authoritative for any reliance.

NOTICE: This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only.

April 17, 1981

Mr. Joel Rubinstein
Sadur and Pelland
Chartered Attorneys at Law
[Recipient address omitted]

Dear Mr. Rubinstein:

The Office of Variance Determination has referred your letter of March 30, 1981, to this office for technical review. The letter requests a temporary variance from sections 29 CFR 1926.105(a) and 1926.105(c)(1) and 29 CFR 1926.750(b)(1)(ii) concerning perimeter netting.

29 CFR 1926.105(a) requires safety nets to be provided when workplaces are more than 25 feet above the ground or water surface, or other surfaces where the use of ladders, scaffolds, catch platforms, temporary floors, safety lines, or safety belts is impractical. This standard has been interpreted by the Courts to mean that employees exposed to falls of 25 feet or more must be protected by safety nets or some other device. Ironworkers tied off to adequately engineered static lines, while working on the horizontal portions of steel trusses, are not in violation of 29 CFR 1926.105(a).

A system of ladders used in accordance with 29 CFR 1926.450 to provide access and egress for ironworkers to the top of the steel properly engineered, would provide required employee protection. ~~Additionally, the alternative method to lift ironworkers in a man-cage complying with both STD 1-11.2 and STD 3-12.3 (copy enclosed) is acceptable.~~
[This document was edited on 6/20/2005 to strike information that no longer represents OSHA policy.]

An ironworker, while in the process of initially connecting steel members, is ordinarily not required to tie off to the steel with a safety belt, due to the hazard presented by the steel when moving and suspended from a crane. Similarly, in those situations in which it is not possible or more hazardous to protect the connector by other means, such as safety nets, we would not consider it a violation of 29 CFR 1926.105(a) or 1926.105(c)(1), if the ironworker made the initial connection without fall protection. However, once the initial connection is completed, the ironworker would have to tie off to the static line on the truss if he is going to move laterally. It appears from the representations in your letter that some of the connecting work at the D.C. Convention Center cannot be performed at all, or cannot be performed without creating greater hazards unless the connector works without fall protection.

If I may be of further assistance, please call or write.

Sincerely,
Bruce Hillenbrand, Deputy Director,
[Directorate of Cooperative and State Programs]

[Correction 6/20/2005. See OSHA Directive CPL 02-01-034 "Inspection policy and procedures for OSHA's steel erection standards for construction" published on 3/22/2002 for the current policy on OSHA's steel erection standards (1926 Subpart R) for construction.]