Toeboards, guardrails, and planks on tank-erection scaffolds

Summary A tank construction contractor requested a scaffold variance. OSHA said toeboards were unnecessary in isolated work without overhead exposure if tools were contained and areas below barricaded. It also set conditions for longer guardrail-support spacing and specified planks at a 10-foot-6-inch span, then said no variance action was needed.
Document
Federal opinion letter
Agency
Occupational Safety and Health Administration (OSHA)
Document number
1980-09-22-0
Date issued
September 22, 1980
Status
Archived by the agency
OSHA labels this an archive document that may no longer represent OSHA policy; it does not give a replacement or withdrawal date.
Status last verified October 10, 2026

Apply this to your situation

This page explains the general guidance. Ask about your specific situation and see what current federal labor law says, with citations.

The current status of this document is unclear
OSHA labels this an archive document that may no longer represent OSHA policy; it does not give a replacement or withdrawal date. It may no longer reflect the agency's current position. Treat this page as historical context, not current guidance, and verify current law before relying on anything here.
About this page: The full text below is the official document from Occupational Safety and Health Administration (OSHA). Ezel adds the plain-English summary and tracks the document's status. The official source linked on this page is authoritative for any reliance.

NOTICE: This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only.

September 22, 1980
Mr. Wayne F. Alch, P.E.
Vice President/Manager
Brooks Erection & Construction Co.
[Recipient address omitted]
Dear Mr. Alch:
This is in reference to your request for a variance from Section 1926.451(a)(4), (5), and (10) Scaffolding, of the Safety and Health Regulations for Construction.
Our technical staff is reevaluation those situations involving the use of toeboards as required by Section 1926.451(a)(4). A number of variances have been granted to members of the Steel Plate Fabricators Association and others to eliminate toeboards from scaffolds during the construction of steel tanks and silos on those types of jobs which were isolated and involved a minimum number of employees. The variances were granted on the basis that employees were not exposed to the hazard or material falling from the scaffold. These variances were not intended to apply on large construction jobs where multiple tradesmen are involved in various tasks which could cause them to be subjected to an overhead hazard.
Therefore, on those tank erection jobs which are isolated situations involving a minimum number of employees from a particular trade (such as the boilermakers) where employees are not subjected to an overhead hazard toeboards would not be required. In these cases, the usual precautions shall be taken such as loose tools and equipment shall be kept in well-designed tool containers and the areas beneath and far enough away from the scaffold to be struck by anything that might fall from above shall be barricaded and posted with clearly visible signs stating "NO TRESPASSING DANGER OVERHEAD WORK".
Section 1926.451(a)(5) states that guard rail support shall be at intervals not to exceed eight (8) feet. On specialty type scaffolding which is system designed to accommodate a particular type of construction guard rail support (metal) may exceed the 8 foot intervals. However, these guardrails shall be at least of equivalent strength, stability and height as those required for the 8 foot intervals of 2" x 4" wood rails required by Section 1926.451(a)(5).
Finally, Section 1926.451(a)(10) requires that all planking shall be Scaffold Grade or equivalent and the maximum permissible span 2" x 10" or wider planks shall be no greater than 10 feet. In those instances, when specialty system designed scaffolding is used, such as in steel plate tank erection, the plank span may be extended to 10' 6" provided that the planks are rough full dimensioned 2" x 12" x 12' planks of Dense Select Structural Grade or equivalent. Three (3) planks with full thickness 2" x 10" x 12' dimensions may be used in lieu of two (2) 2" x 12" x 12' planks provided that they are clamped or bonded together at the midpoint of the span, in order to spread the weight of the employees.
Affected employees and their authorized representatives shall be notified of this clarification in the same manner they were informed of your request for a variance.
Accordingly, no further action will be taken on your request for a variance.
Sincerely,
James J. Concannon
Director
Office of Variance Determination