Farm-equipment guard strength and location

Summary A farm-equipment manufacturer asked about guard strength, tractor shields, and guarding by location. OSHA said guards should resist reasonably predictable forces, including a vertical fall where that could occur. It also said distance alone did not settle accessibility, and full PTO guarding required no exposed shaft between shields.
Document
Federal opinion letter
Agency
Occupational Safety and Health Administration (OSHA)
Document number
1976-07-02-0
Date issued
July 2, 1976
Status
Active
Status last verified October 10, 2026

Apply this to your situation

This page explains the general guidance. Ask about your specific situation and see what current federal labor law says, with citations.

About this page: The full text below is the official document from Occupational Safety and Health Administration (OSHA). Ezel adds the plain-English summary and tracks the document's status. The official source linked on this page is authoritative for any reliance.

July 2, 1976

Mr. T. H. Morrell
Vice President, Engineering
Owatonna Manufacturing Company, Inc.
[Recipient address omitted]
Dear Mr. Morrell:

Assistant Secretary Morton Corn has asked me to respond to your letter of May 13, 1976 (copy enclosed), regarding clarification of certain standards in 29 CFR 1928.57. Guarding of Farm Field Equipment, Farmstead Equipment, and Cotton Gins. In addition, this letter confirms a phone conversation with you by a member of my staff.

On page one of your correspondence, comments on 29 CFR 1928.57(a)(8)(ii) and (b)(1)(ii) are presented. The Occupational Safety and Health Administration (OSHA) offers the following clarifications on these two standards:

29 CFR 1928.57(a)(8)(ii): the term, "--- falling against the guard, ---- "would include vertical as well as lateral forces that may be exerted upon the guard. Guards, particularly those located close to the ground, should be able to withstand vertical forces resulting from an employee falling vertically on the guard. The actual force exerted upon the guard would vary due to the location of the guard in relation to the location of the employee who might fall on it.

If there is no chance of a vertical fall on guard, then the guard would not have to be designed to withstand a vertical fall. In short, guards need to be designed to withstand the force which one would exert on it in a reasonably predictable accident.

29 CFR 1928.57(b)(1)(ii): "---. The master shield shall have sufficient strength to prevent permanent deformation of the shield when a 250 pound operator mounts or dismounts the tractor using the shield as a step." In this case the force exerted on the shield is usually downward (vertical).

On page two to your correspondence, you offer two interpretations of "guarding by location," (29 CFR 1928.57(a)(9)). Your interpretations may be applicable and correct in some situations and not in others. OSHA offers the following clarification on your two interpretations:

An examination of 29 CFR 1928.57(a)(7)(ii) reveals that a guardrail or fence is to be used as a method of guarding only when a guard or shield or guarding by location is infeasible.

"Guarding by location" as defined in 29 CFR 1928.57(a)(9) is intended to mean that no employee, including but not limited to the operator, can inadvertently (unintentionally) come in contact with the hazard during the normal course of his duties.

There may be components of a machine located more than 3 feet from the outside of the machine which are guarded by locations because they are covered by other parts of the machine or otherwise inaccessible. However, there may be components which, even though located more than 3 feet from an employee, are not guarded by location because these parts are exposed and are in areas of the machine into which an employee might reach during the course of his duties,

On page three of your correspondence, you offer an interpretation of "full guarding." OSHA offers the following comments on this interpretation:

OSHA agrees with your interpretation of "full guarding", as long as there is no exposed shaft between master shield and the implement power take-off (PTO) shield and the strength requirements are met.

If I may be of any further assistance, please feel free to contact me.

Sincerely,
Bert M. Concklin
Deputy Assistant Secretary

Enclosures