Caterpillar diesel engine approval plate

Summary MSHA says the Caterpillar Model 3306 PCNA diesel engine may be used in permissible equipment even when its existing plate shows Category B approval. The engine also has Category A approval, but the machine must use and display the Category A ventilation quantity of 9,500 cubic feet per minute. The policy concerns this specific engine and approval plate.
Document
Federal administrative policy
Agency
Mine Safety and Health Administration (MSHA)
Document number
P11-V-10
Date issued
April 1, 2011
Status
Active
MSHA lists this letter as last validated 2026-03-26, with an expiration date of 2028-03-31.
Status last verified October 24, 2026

Apply this to your situation

This page explains the general guidance. Ask about your specific situation and see what current federal labor law says, with citations.

About this page: The full text below is the official document from Mine Safety and Health Administration (MSHA). Ezel adds the plain-English summary and tracks the document's status. The official source linked on this page is authoritative for any reliance.

EFFECTIVE DATE: 4/1/2011
EXPIRATION DATE: 3/31/2028
LAST VALIDATED: 3/26/2026

PROGRAM POLICY LETTER NO. P11-V-10

FROM:
KEVIN G. STRICKLIN
Administrator for
Coal Mine Safety and Health

LINDA F. ZEILER
Acting Director of Technical Support

SUBJECT:
Approval Plate for Caterpillar Model 3306 PCNA Diesel Engine

Scope

This Program Policy Letter (PPL) affects underground coal mine operators using diesel-powered equipment, miners and miners' representatives, and Coal Mine Safety and Health (CMS&H) enforcement personnel.

Purpose

This PPL clarifies that Caterpillar Model 3306 PCNA diesel engines installed in permissible equipment bearing approval plates (7E-B003) are approved for use in permissible equipment even though the approval plates indicate the engines are approved only as Category B (nonpermissible) engines.

Policy

Caterpillar Model 3306 PCNA diesel engines are approved by the Mine Safety and Health Administration (MSHA) under Part 7, Subpart E as both a Category A and B approved engine. Mechanically, there is no difference in the construction and performance of the basic engine. MSHA will permit the use of a Model 3306 PCNA engine that has a Category B approval tag affixed to it to be used in a permissible machine. The gaseous ventilation quantity specified for the Category A approval must be used as required under 75.325(f) through (k) and the Category A gaseous ventilation quantity must be stamped on the permissible machine's approval plate. The ventilation quantity for a Category A, Model 3306 PCNA engine is 9,500 cubic feet per minute.

Background

Part 75.1907(b)(5) states that permissible diesel-powered equipment manufactured on or after November 25, 1999, shall incorporate a power package approved in accordance with Part 7, Subpart F. A Part 7, Subpart F power package must incorporate a Part 7, Subpart E, Category A diesel engine and have a Category A engine approval plate affixed to the engine. The Caterpillar Model 3306 PCNA diesel engines are approved under Part 7, Subpart E as both a Category A and B engine. Some Model 3306 PCNA engines have been installed in permissible machines that have a Category B tag affixed to the engine. Except for the gaseous ventilation rate and particulate index assigned to the engine, there is no mechanical difference between the two engines.

Since the Model 3306 PCNA engine is no longer in production, this tagging issue only affects the current engine inventory. In the past, Caterpillar customers ordered an engine based on an "arrangement number." The arrangement number for the Category A engine includes a water-cooled exhaust manifold. However, many power package manufacturers do not use the Caterpillar water-cooled exhaust manifold for their Subpart F approval. Consequently, a Category B approval tag was affixed to the engine by Caterpillar when customers ordered the Model 3306 PCNA without the water-cooled exhaust manifold.

Authority

The Federal Mine Safety and Health Act of 1977 and 30 C.F.R. §§7.82, 7.90, 7.98, 75.1907, and 75.325.

Internet Availability

This program policy letter may be viewed on the Internet by accessing MSHA's home page at (www.msha.gov) and choosing Compliance Info then "Program Policy Letters."

Issuing Office and Contact Person

Mine Safety and Health Enforcement, Safety Division
Rodney Adamson, (202) 693-9549
E-mail: Adamson.Rodney@dol.gov

Technical Support, Approval and Certification Center
Jeffrey Moninger, (304) 547-2324
E-mail: moninger.jeffrey@dol.gov

Distribution

MSHA Program Policy Manual Holders
Miners' Representatives
Coal Mine Operators
Manufacturers of Mine Equipment
Special Interest Groups

What does federal law require in your situation?

Ezel checks current federal labor law against your facts and answers with citations.

Opens in Ezel Pro.

  • Checks the law as it stands today, not only this page
  • Cites every source it relies on, so you can verify it
  • Chat, drafting and research in one workspace