Secretary of Labor v. The Monongalia County Coal Company
Secretary of Labor v. The Monongalia County Coal Company (FMSHRC WEVA 2015-509): Flagrant and unwarrantable designations deleted
What's the rule today?
This ALJ decision was superseded by the Commission's decision in the same case. Ezel starts from the controlling decision and answers your situation under current law, with citations.
Plain-English summary
Monongalia stipulated to significant-and-substantial violations involving extensive combustible accumulations along a belt and an inadequate preshift examination, but disputed unwarrantable-failure and flagrant designations. Judge Jerold Feldman found high negligence and serious violations, yet held that documented cleanup and repair activity kept the conduct from rising to aggravated unwarrantable failure. He also rejected the flagrant designation because the accumulations were about three-and-a-half miles from the working section and the Secretary had not shown that a resulting fire could reasonably be expected to proximately cause death or serious bodily injury. Both orders were modified to section 104(a) citations, and penalties of $60,000 and $22,200 were assessed. On Commission review, a later settlement reinstated both unwarrantable-failure designations, dropped the flagrant issue, and retained those penalties.
Decision snapshot
- Cited standards: 30 C.F.R. §§ 75.400 and 75.360(a)(1)
- Outcome: Both orders remained S&S but were modified to section 104(a) citations; the flagrant and unwarrantable-failure designations were deleted and total penalties were set at $82,200.
- Subsequent review: The Commission-approved settlement in weva-2015-0509-commission reinstated both unwarrantable-failure designations, abandoned the flagrant designation, and preserved the $82,200 total.
- Key point: The judge distinguished high negligence from aggravated conduct and required case-specific proof that an alleged flagrant violation could proximately cause death or serious bodily injury.
Full text (FMSHRC public release)
FEDERAL MINE SAFETY AND
HEALTH REVIEW COMMISSION
OFFICE OF ADMINISTRATIVE
LAW JUDGES
1331 PENNSYLVANIA AVE.,
N.W., SUITE 520N
WASHINGTON,
DC 20004-1710
TELEPHONE: 202-434-9958
/ FAX: 202-434-9949
July 30, 2018
SECRETARY OF LABOR
MINE SAFETY AND HEALTH
ADMINISTRATION (MSHA),
Petitioner
v.
THE MONONGALIA COUNTY COAL
COMPANY, successor to
CONSOLIDATION COAL COMPANY,
Respondent
CIVIL PENALTY PROCEEDINGS
Docket No. WEVA 2015-0509
A.C. No. 46-01968-374332
Docket No. WEVA 2015-0632
A.C. No. 46-01968-377533
Mine: Monongalia County Mine (formerly
Blacksville No. 2)
DECISION
Appearances: John
Nocito, Esq., Helga Spencer, Esq., U.S. Department of Labor, Office of the Solicitor,
Philadelphia, Pennsylvania for Petitioner;
Jason
Hardin, Esq., Artemis Vamianakis, Esq., Fabian VanCott, Salt Lake City, Utah for
Respondent.
Before: Judge
Feldman
The captioned civil
penalty proceedings are before me based upon Petitions for Assessment of Civil Penalty
filed by the Secretary of Labor (“the Secretary”) pursuant to section 105(d) of
the Federal Mine Safety and Health Act of 1977, as amended by the Mine Improvement
and New Emergency Response Act of 2006 (“Act,” “Mine Act,” or “New Miner Act”),
30 U.S.C. § 815(d), against the Respondent, Monongalia County Coal Company (“Monongalia”). [1]
The hearing in these matters was held on March 7, 2017, through
March 9, 2017, in Morgantown, West Virginia. [2] The parties’
post-hearing briefs have been considered in the disposition of these matters. At
issue in WEVA 2015-0632 is 104(d)(2) Order No. 8059209, which alleges a violation
of the mandatory safety standard in section 75.400 as a result of impermissible
combustible coal accumulations along the 5 West No. 1 belt. [3] Resp’t Ex.
- The Secretary seeks to impose an enhanced civil penalty of $121,300.00 under
the “repeated” flagrant provisions of section 110(b)(2) of the New Miner Act. This
statutory provision provides:
Violations
. . . that are deemed to be flagrant may be assessed a civil penalty of not more
than $220,000. For purposes of the preceding sentence, the term “flagrant” with
respect to a violation means a reckless or repeated failure to make reasonable efforts
to eliminate a known violation of a mandatory health or safety standard that substantially
and proximately caused, or reasonably could have been expected to cause, death or
serious bodily injury.
30
U.S.C. § 820(b)(2).
In American Coal
Company , the Commission crafted two interpretations of the “repeated” language
in section 110(b)(2), one “narrow” and one “broad.” American Coal Co. , 38
FMSHRC 2062 (Aug. 2016). Under the “narrow” interpretation, a violation can be designated as flagrant
if the duration of the violation, without regard to a history of violations, is
sufficient to warrant a “repeated” designation. Id . at 2065. Thus, the Commission’s
“narrow” interpretation of the flagrant provisions of the Act concerns a discrete
ongoing violation. Id . In contrast, the Commission articulated that
its “broad” approach involves a recurrent-type violation analysis, i.e., analysis
of several discrete yet similar violations. Id . This approach allows
for a “repeated” flagrant violation based on a relevant history of similar violations.
Monongalia has stipulated
to the fact of the violation of section 75.400 and to the significant and substantial
(“S&S”) nature of the violation. [4]
Resp’t Post-Hr’g Br. at 2 n.3. However, Monongalia challenges that the subject violation
was attributable to an unwarrantable failure, and that the violation constitutes
a “repeated” flagrant violation. Resp’t Post-Hr’g Br. at 3, 39. The Secretary asserts
that the accumulations violation cited in Order No. 8059209 can be designated as
“repeated” based on either the Commission’s “broad” or “narrow” interpretation.
Sec’y Post-Hr’g Br. at 39, 49.
Also before me is
104(d)(2) Order No. 8059212 in Docket No. WEVA 2015-0509 that alleges a violation
of section 75.360(a)(1) of the Secretary’s regulations for a failure to conduct
an adequate preshift examination of the 5 West No. 1 belt during the preceding midnight
shift for the day shift of July 30, 2014. [5] The Secretary proposes a civil
penalty of $40,300.00 for Order No. 8059212. Resp’t Ex. at 6. Monongalia has not
challenged the fact of the violation or the S&S designation. Resp’t Post-Hr’g
Br. at 58-62. However, Monongalia disputes, in essence,
that the cited inadequate preshift examination is attributable to an unwarrantable
failure. Id .
I. Procedural History
The Secretary has
identified three non-flagrant predicate 104(d) orders, contained in Docket Nos.
WEVA 2015-74, WEVA 2015-425, and WEVA 2015-473, in support of his flagrant designation
in Order No. 8059209 under the “broad” approach. Given the Secretary's asserted
relevance of the alleged predicates, these predicate dockets were consolidated with
the captioned dockets and stayed on May 12, 2016, pending final disposition of Oak
Grove Res. , LLC , 38 FMSHRC 957 (May 2016) (ALJ). Oak Grove addressed
the evidentiary requirements for a “repeated” flagrant designation with respect
to an alleged violation of section 75.400. After the 30-day appeal period for the
May 3, 2016, Oak Grove decision had expired, the predicate dockets in WEVA
2015-74, WEVA 2015-425, and WEVA 2015-473 were severed on June 14, 2016. Consolidation
Coal Co. , 38 FMSHRC 1573 (June 2016) (ALJ). [6]
Oak Grove recognized that
the Commission had held “that past [relevant] violative conduct may be considered
in determining whether a condition can be cited as a ‘repeated’ flagrant violation.”
Oak Grove , 38 FMSHRC at 964, n.6 (citing Wolf Run Mining Co .,
35 FMSHRC 536, 541 (Mar. 2013)). However, Oak Grove held that a violative
condition that does not otherwise meet the statutory definition of flagrant cannot
be elevated to flagrant status simply based on a history of violations. Id .
38 FMSHRC at 960-61. Consequently, in an interlocutory order, the flagrant designation
in Oak Grove was deleted based on the Secretary’s failure to demonstrate
the subject accumulations could reasonably have been expected to proximately cause
death or serious bodily injury. Oak Grove Res ., 37 FMSHRC 1311, 1321 (June
2015) (ALJ). The Secretary did not appeal the interlocutory order.
Simply put, Oak
Grove held that, while a history of violations may be a relevant consideration
in assessing a civil penalty, predicate violations are not dispositive of whether
an alleged flagrant violation is properly designated as “repeated.” Oak Grove
Res ., 38 FMSHRC at 960-61. The ALJ holding in Oak Grove was rejected
in the American Coal remand, in which the Commission concluded that a history
of similar recurring violations can satisfy the “repeated” element for a flagrant
violation. 38 FMSHRC at 2065. However, the Commission did not specify the exact
role played by a violation history in a “broad” “repeated” flagrant analysis. Consequently,
on remand the Commission directed the ALJ to fashion his own interpretation of section
110(b)(2), which permits the Secretary to establish a “repeated” flagrant violation
“by taking the operator’s history of previous accumulations violations into account.”
Id . at 2082.
As the significance
of a relevant violation history remained unclear following American Coal ,
the parties were advised that the March 7, 2017, hearing in these matters would
be limited to the Commission’s “narrow” analysis. Consolidation Coal Co. ,
39 FMSHRC 423, 425 (Feb. 22, 2017) (ALJ). The parties were invited to address, in
their post-hearing briefs, whether Monongalia’s two-year history of 147 section
75.400 violations is sufficient to support a “repeated” flagrant designation under
the “broad” approach. Id . The parties have addressed this issue. Sec’y Post-Hr’g
Br. at 46; Resp’t Post-Hr’g Br. at 37.
II. Stipulations
At trial the parties
agreed on the following stipulations: [7]
-
Monongalia is
an “operator,” as defined by § 3(d) of the Federal Mine Safety and Health Act of
1977, as amended, 30 U.S.C. § 803(d), of the coal mine at which the Orders at issue
in this proceeding were issued. -
This proceeding
is subject to the jurisdiction of the Federal Mine Safety and Health Review Commission
and its designated Administrative Law Judge pursuant to sections 105 and 113 of
the Mine Act. -
True copies of
the Orders at issue in this proceeding were served on Monongalia as required by
the Mine Act. -
The Orders contained
in Exhibit “A” attached to the Secretary’s Petition in the subject dockets are authentic
copies of the Orders at issue in this proceeding. -
The imposition
of the proposed penalties will not affect Monongalia’s ability to continue in business. -
The Mine Operator
engaged in mining operations in the United States and its mining affects interstate
commerce. -
The Blacksville
No. 2 Mine now operates as The Monongalia County Mine. -
The conditions
described in Order No. 8059209 constitute a violation of 30 C.F.R. § 75.400, and
the violation was S&S and reasonably likely to result in an injury or illness
affecting one miner. -
The conditions
described in Order No. 8059212 constitute a violation of 30 C.F.R.
§ 75.360(a)(1).
- The conditions
described in Order No. 8059212 were S&S and reasonably likely to result in an
injury or illness affecting one miner.
III. Order No. 8059209
Findings of Fact
The Monongalia County
Mine is a large underground coal mine located in the Pittsburgh coal seam. Tr. I
- MSHA records reflect that, as of July 30, 2014, the date of the subject mine
inspection, more than 3 million tons of coal had been extracted from the Monongalia
Mine. Sec’y Pet. for Assessment of Civil Penalties, Docket Nos. WEVA 2015-0509 and
WEVA 2015-0632, Ex. A.
At all times relevant
to these proceedings, Monongalia was operating four mechanized mining units (“MMU”):
two for the main section, one in the development section, and one for the longwall
section. Tr. I 67, 151-52; Resp’t Ex. 19. Mine operations were performed during
three daily production shifts. Tr. I 68. The day shift was conducted from 8:00 a.m.
through 4:00 p.m.; the afternoon shift was conducted from 4:00 p.m. through 12:00
a.m.; and the midnight shift was conducted from 12:00 a.m. to 8:00 a.m. Id .
at 69.
There are approximately
12-and-a-half miles of belt lines in the Monongalia County Mine. Id . at 158. Coal production from the 20W Headgate and 13W Longwall
MMUs was carried outby from the 5 North and 5 South belts toward the 5 North/5 South
belt transfer point, where the coal was transferred onto the 5 West No. 2 belt.
Id . at 163. The 5 West No. 2 conveyor belt travels outby from the 5 North/5
South belt transfer point to the 5 West No. 2 belt transfer point located at the
59 block, where it dumps onto the 5 West No. 1 belt, the site of the subject accumulations.
Id . at 163-4. The 5 West No. 1 belt is approximately 75,000 feet long. Id .
at 174. The 5 West No. 1 belt transfers coal onto the 6 North belt at the 5 West
No. 1 transfer located at the 1 block. Id . at 91, 164; Resp’t Exs. 19, 20;
Sec’y Ex. 45 (denoted in blue).
The Monongalia County
Mine is classified as a gassy mine in that it liberates between six and seven million
cubic feet of methane in a 24 hour period. Tr. I 69-70. As such, the mine is subject
to a five-day spot inspection in accordance with section 103(i) of the Act. Id .
at 70; 30 U.S.C § 103(i). On July 30, 2014, MSHA Inspector Tyler Peddicord (“Peddicord”)
arrived at the Monongalia Mine at approximately 7:30 a.m. to conduct an E02 methane
spot inspection and a regular E01 inspection at the 13W Longwall section. Tr. I
70-71. Prior to traveling underground, Peddicord reviewed the preshift, on-shift,
and electrical examination records for the 13W Headgate, the area of the mine he
planned to inspect as part of his E01 inspection. Id . at 71. After
reviewing the examination book, Peddicord met with miners’ representative Chad Newbraugh
and mine representative Doug Moyer to discuss his planned inspection for the day.
Id . at 72.
Peddicord entered
the mine accompanied by Newbraugh and Moyer to perform an E02 section 103(i) methane
spot inspection in the 13 W Headgate section. Id . at 71, 74, 147; Tr. II
27-28. They traveled by mantrip. Tr. I 73. However, due to obstructions present
at the entry of the 5 West track, the inspection party was not immediately able
to advance to the 13W Headgate via mantrip. Id . at 73. As a result, the inspection
party exited the mantrip, whereupon Peddicord decided to conduct an E01 inspection
of the 5 West No. 1 conveyor belt, which had not yet been subject to an MSHA quarterly
inspection. Id . at 74. The Secretary has proffered a map denoting the area
inspected by Peddicord in the 5 West No. 1 belt entry. Sec’y Ex. 45 (denoted in
orange).
Peddicord began his
inspection at the 1 block, where 5 West No. l/6 North transfer was located, and
proceeded to travel inby by up to the 40 block. Id . at 93; Sec’y Ex.
45; Resp’t Exs. 19, 20. In the course of his travels, he observed extensive accumulations
of coal dust covering the mine floor, roof, ribs, belt structures, waterlines, and
power cables, starting at the 6 block and extending inby. Id . at 95-96,
107; Sec’y Ex.1; Resp’t Ex. l. The coal dust accumulations he observed were black
in color and measured approximately 1/8 inch for a distance of approximately 3400
feet, measured from the 6 block to 34 the block. Tr. I 95, 106-07, 133-35. In addition
to the 1/8 inch depth of accumulations, there were ten discrete locations, several
of which were located in the vicinity of the 27 block where the misaligned belt
was located, that measured 16 to 24 inches in depth. Id . at 104-06;
Sec’y Exs. 4, 6. At these locations there were a total of 19 rollers turning in
coal. Tr. I 107. Each location measured approximately two to three feet in length
and three feet in width. Id . at 104-6. Thus, these locations totaled approximately
25 to 33 feet in length. Id . at 79, 109, 200; see Sec’y Exs.
1, 8, 45.
Of the nineteen rollers
turning in coal, there was one broken roller at the 7 block and one frozen roller
at the 29 1/2 block. Tr. I at 93, 105, 109-10, 112-13; Tr. II 65,
91; Sec’y Exs. 3,11. The broken roller at the 7 block made substantial noise as
a result of metal-to-metal contact and had heated to the point that it steamed when
water was applied. Tr. I at 78, 114; Sec’y Ex. 3. In addition, a belt misalignment
approximately fifty feet in length, starting at the 27 block, caused the belt conveyor
to rub against six bottom roller cradles, [8]
all of which were covered in coal dust. Tr. II 69; Sec’y Ex. 4. The continued rubbing
between the belt conveyor and cradles created friction sufficient to completely
remove the top paint coating from all six cradles revealing the “shiny metal” underneath.
Tr. I 117. Inspector Peddicord was concerned that continued rubbing between the
belt and roller cradles would cut into the belt and result in a tear. Id .
Based on his observations, Peddicord initially informed Moyer that he was issuing
a 104(a) citation alleging a violation of section 75.400. Tr. I 96, 107.
As the inspection
party continued inby, additional accumulations were observed, extending to the 34
block that were in proximity to the two damaged rollers noted above. Sec’y Ex. 1;
Resp’t Ex 1. Peddicord also observed a portion of misaligned belt measuring approximately
50 feet in length. Tr. I 96-107; Sec’y Exs. 8, 45. Peddicord believed there were
numerous points of contact that could create friction that would generated heat,
causing an ignition hazard which could ignite a fire. Tr. I 78, 108-11, 128; Tr.
II 146, 147-49. There were no active workings in proximity to the cited accumulations
along the 5 West No. 1 belt. Tr. I 170. In fact, the 5 West No. 1 belt entry, which
was ventilated with fresh air, was located approximately three and a half miles
from the working long wall face. Id . at 167; Tr. II 30. Consequently, Peddicord
testified that his major concern was ignition (combustion) of the coal accumulations
rather than propagation. Tr. I 78. In this regard, the Secretary’s counsel conceded
that he was asserting that Peddicord’s concern was “a mine fire hazard and not an
explosion hazard.” Tr. II 29.
Peddicord concluded
that the totality of the circumstances necessitated the removal of the 5 West No.
1 conveyor belt from service in order to repair and replace the damaged rollers,
realign the belt, shovel underneath the nineteen bottom rollers turning in coal
and apply rock dust in the belt entry. Tr. II at 62, 66, 140, 143. Consequently,
Peddicord ultimately informed Moyer that he was issuing a 104(d) order instead of
a 104(a) citation. Tr. I 143. It took fifteen to twenty miners approximately 10
hours to abate the cited conditions. Id . at 141; Sec’y Ex. 8 at 29.
Based on his observations,
Peddicord issued Order No. 8059209 alleging a violation of section 75.400. The order
states:
Accumulations of
combustible material is allowed to accumulate over previously rock dusted surfaces
on the 5-West company #1 belt conveyor in the following locations: 1) Accumulations
of loose coal, and coal fines is allowed to exist from 6 block to 34 block. The
accumulations measured 16 feet wide, 1/8 inch thick, and approximately 3400 feet
long. These accumulations are located on the mine floor, roof, ribs, and belt structure.
The accumulations are dark brown in color. 2) Accumulations are present 10 1/2 block
and in contact with both bottom rollers. These accumulations of coal fines/belt
fines measured 3 feet wide, 2 foot long, and 16 inches deep. 3) Also, accumulations
of dry coal fines/belt fines are present at the 12 1/4 block and in contact with
both bottom rollers. These accumulations measure 3 feet long, 3 feet wide, and 24
inches deep. 4) Accumulations of loose coal, and coal fines is present at 12 1/2
block, and are in contact with on bottom roller that is turning in accumulations.
These accumulations measured 3 feet long, 3 1/2 feet wide, and 20 inches high. 5)
Also, accumulations of coal fines, and loose coal is in contact with bottom roller
at 17 1/2 block. These accumulations measured 1 foot wide, 2 feet long, and 20 inches
deep. 6) Also, accumulations of coal fines/belt fines is present at 21 3/4 block
and contacting both bottom rollers. These accumulations measured 2 feet wide, 2
feet long, and 22 inches high. 7) Also, accumulations just inby 23 block are in
contact with inside part of both bottom rollers, allowing rollers to turn in accumulations.
These accumulations are coal fines, and belt fines. These accumulations measured
3 feet long, 1 foot wide, and 10 inches deep. 8) Also, accumulations of coal fines/belt
fines is in contact with both bottom rollers at 23 1/2 block. The accumulations
measured 2 feet wide, 2 foot long, and 12 inches deep. 9) Also, accumulations of
coal fines/belt fines is present at 24 block and in contact with both bottom rollers.
These accumulations measured 3 feet long, 1 foot wide, and 10 inches wide. These
accumulations were dry and black in color. 10) Also, accumulations of dry coal fines/belt
fines are in contact with 2 consecutive bottom rollers at 25 1/2 block. The accumulations
measured 3 feet wide, 1 1/2 wide, and 10 inches deep in both locations. 11) Also,
accumulations of coal fines/belt fines is allowed to exist on mine floor, and in
contact with bottom roller. Accumulations measured 1 1/2 feet wide, 1 foot long,
and 18 inches deep at 19 3/4 block. This mine is on a 5-day 103(I) spot inspection
for liberating over 1 million cubic feet of methane in a 24 hour period. Citation
8059210, and Citation #8059211 are issued in conjunction with this order for damaged
rollers, and belt rubbing metal components in same areas as cited accumulations.
This creates a confluence of factors. Miners work and travel in these areas each
shift in performance of their duties. There is evidence that these accumulations
have existed for an extended period of time, due to the amount of the accumulations
present, and foot prints in the walkway through the accumulations. A certified mine
examiner travels this belt conveyor 3 times a day, and should have been aware that
these conditions were present. Accumulations/roller spillage was visible to the
most casual observer. Examinations are the first line of defense for the health
and safety of the miners. These conditions were obvious and extensive and should
have been reported and corrected. History has shown that frictional heat sources
such as belt rubbing structure causes mine fires. If normal mining operations were
to continue and these conditions were left unabated it is reasonably likely that
friction sources present will ignite accumulations, and/or contribute to a fire
and/or explosion occurring nearby. The operator removed the belt from service to
correct ignition sources. Numerous 75.400 citations have been issued at this mine
in the past. This is the third 75.400 order issued on belt conveyors at this mine
in the past 6 months. The operator has engaged in aggravated conduct constituting
more than ordinary negligence. The belt was in operation at time of issuance. A
mine fire occurred at this mine on 3-12-12. This violation is an unwarrantable failure
to comply with a mandatory health and safety standard.
Sec’y Ex. 1; Resp’t Ex. 1.
In addition to Peddicord
noting the broken roller at the 7 block and the frozen roller at the 29 1/2 block
in Order No. 8059209, Peddicord issued Citation No. 8059210, which is not a subject
of this proceeding, citing the two malfunctioning rollers as an S&S violation
of section 75.1731(a). Sec’y Ex. 3; Resp’t Ex. 2. The mandatory standard in section
75.1731(a) requires damaged rollers that pose a fire hazard to be immediately repaired
or replaced. 30 C.F.R. § 75.1731(a). Peddicord designated this damaged roller violation
as reasonably likely to cause an injury leading to lost workdays or restricted duty.
Sec’y Ex. 3; Resp’t Ex. 2. He attributed the violation to a moderate degree of negligence.
Id . The Secretary proposed a civil penalty of $1203.00 for Citation No. 8059210.
Sec’y Post-Hr’g Br. at 8.
Peddicord also issued
Citation No. 8059211, also not a subject of this proceeding, citing an S&S violation
of section 75.1731(b) as a result of the approximately fifty feet of misaligned
belt that he had observed. Sec’y Ex. 4; Resp’t Ex. 3. The mandatory standard in
section 75.1731(b) prohibits improperly aligned conveyor belts. 30 C.F.R. § 75.1731(b).
Peddicord designated the cited violation as reasonably likely to result in lost
workdays or restricted duty. Sec’y Ex. 4. Peddicord attributed the violation to
a low degree of negligence. Id . The Secretary proposed a civil penalty of
$585.00 for Citation No. 8059211. Sec’y Post-Hr’g Br. at 8.
Citation Nos. 8059210
and 8059211 were the subjects of a Joint Motion to Approve Settlement in Docket
No. WEVA 2015-0033. Sec’y Ex. 5. The settlement terms were that Monongalia accepted
Citation Nos. 8059210 and 8059211 as unmodified and agreed to pay the initially
proposed civil penalties of $1203.00 and $585.00, respectively. Id . These
settlement terms were approved in a Decision Approving Settlement issued on April
21, 2016. Sec’y Ex. 5; Tr.
I 116.
Monongalia does not
dispute that the cited accumulations in Order No. 8059209 constitute a section 75.400
violation. Resp’t Post-Hr’g Br. at 49. However, Monongalia alleges several mitigating
factors with respect Order No. 8059209. Id . at 40-44. With respect to the
presence of potential ignition sources, Monongalia argues that Peddicord only found
two out of 4000 rollers to be defective and fifty feet out of 5000 feet of belt
to be misaligned. Id . at 40; Tr. I 197-200. With regard to the length of
time the violative conditions existed, Monongalia argues that the ten discrete areas
of deeper accumulations were the result of broken chains on the belt and that these
accumulations existed for less than a day. Resp’t Post-Hr’g Br. at 40. Furthermore,
Monongalia alleges that it was engaging in an ongoing process of repairing chains
and cleaning the associated accumulations. Id .
With respect to the
risk of danger the violative conditions posed, Monongalia argues that there was
no methane in the belt entry and that the cited accumulations were not in contact
with the cited ignition sources. Id . at 41-2; Tr. I 180-1; Tr. II 168-9.
Additionally, Monongalia argues that the distance of the accumulations from the
mining face, and the Secretary’s characterization of no more than lost workdays
resulting from the risk posed by the defective rollers and misaligned belt undermine
the Secretary’s assertion in Order No. 8059209 that the accumulations will result
in a fatality. Resp’t Post-Hr’g Br. at 42; Tr. I 166-7.
With respect to knowledge
and obviousness, Monongalia does not dispute that it was aware of the cited accumulations.
Resp’t Post-Hr’g Br. at 43. In this regard, Monongalia was on notice that greater
efforts were required to comply with section 75.400 by virtue of the reported capital
expenditures it incurred to improve the conditions in 5 West No. 1 belt entry. Tr.
II 161-62. In addition, Monongalia asserts that it had made efforts to eliminate
the violative conditions by rock dusting and repairing broken belt chains. Tr. II
313, 321.
Disposition
a.
S&S
Monongalia does not contest the cited accumulation violation,
Citation No. 8059209,
or that the violation was properly designated as S&S. Sec’y Post-Hr’g Br. at 3-4.
However, an understanding of the S&S legal framework is helpful in providing
context to the parties’ stipulations.
The Mine Act describes an S&S violation as one “of
such nature as could significantly and substantially contribute to the cause and
effect of a coal or other mine safety or health hazard.” 30 U.S.C. § 814(d)(1).
A violation is properly designated as S&S in nature if, based on the particular
facts surrounding that violation, there exists a reasonable likelihood that the
hazard
contributed
to by the violation will result in an injury or an illness of a reasonably serious
nature. Cement Div., Nat'l Gypsum , 3 FMSHRC 822, 825 (Apr. 1981). In Mathies
Coal Co .,
6
FMSHRC 1, (Jan. 1984), the Commission explained:
In
order to establish that a violation of a mandatory safety standard is S&S under
National Gypsum, the Secretary of Labor must prove: (1) the underlying violation
of a mandatory safety standard; (2) a discrete safety hazard--that is, a measure
of danger to safety--contributed to by the violation; (3) a reasonable likelihood
that the hazard contributed to [by the violation] will result in an injury; and
(4) a reasonable likelihood that the injury in question will be of a reasonably
serious nature.
Id . 6 FMSHRC at 3-4;
see also Austin Powder Inc. v. Sec'y of Labor , 861 F.2d 99, 103-04 (5th Cir.
1988), aff'g 9 FMSHRC 2015, 2021 (Dec. 1987) (approving the Mathies
criteria).
Once the fact of a violation has been established under
step one of Mathies , the second Mathies step addresses the extent
to which the violation contributes to a particular hazard. In a change to the Commission’s
long-standing interpretation of the Mathies criteria, the Commission now
has opined that the second step analysis is “primarily concerned with likelihood
of the occurrence of the hazard against which a mandatory safety standard is directed.”
Newtown Energy , 38 FMSHRC at 2037 (citing Knox Creek Coal Corp.
v. Sec'y of Labor , 811 F.3d 148, 163 (4th Cir. 2016)). Thus, step two of the
Mathies test now involves a two-part analysis: first, identification of the
hazard created by the subject violation of the safety standard; and second, “a determination
of whether, based on the particular facts surrounding the violation, there exists
a reasonable likelihood of occurrence of the hazard against which the mandatory
safety standard is directed.” Newtown Energy , 38 FMSHRC at 2038. Consideration
must be given to both the time frame that a violative condition existed prior to
the issuance of a citation, and the time that it would have existed if normal mining
operations had continued. Bellefonte Lime Co. , 20 FMSHRC 1250, 1255 (Nov.
1998) (citing Rushton Mining Co. , 11 FMSHRC 1432, 1435 (Aug. 1989)); Halfway,
Inc. , 8 FMSHRC 8, 12 (Jan. 1986).
Under the Commission’s
analysis in Newtown Energy , when evaluating the third Mathies criterion,
the analysis assumes that the hazard identified in step two has been realized, and
then considers whether the hazard would be reasonably likely to result in injury,
again, in the context of “continued normal mining operations.” Newtown
Energy , 38 FMSHRC at 2038 (citing Knox Creek Coal Corp. , 811 F.3d at
161-62); Peabody Midwest Mining, LLC , 762 F.3d 611, 616 (7th Cir. 2014);
Buck Creek Coal , 52 F.3d 133 at 135; U.S. Steel Mining Co. , 6 FMSHRC
1573, 1574 (July 1984)). In sum, while the methodology for analyzing S&S under
the long-standing Mathies criteria has been modified by Newtown Energy ,
the Commission acknowledged that “the ultimate inquiry has not changed.” 38 FMSHRC
at 2038, n.8.
Given
the fact that section 75.400 violations are the most commonly cited, the Commission
has identified the elements necessary to create a fire or explosion hazard. Resp’t Ex. 15; Most
Frequently Cited Standards for 2014, Underground Coal, Jan. 1, 2014 – Dec. 31, 2014 ,
MSHA, https://arlweb.msha.gov/stats/top20viols/top20home.asp (“Most Commonly Cited
Standards”). When analyzing the degree of hazard posed by section 75.400 violations,
the Commission looks to whether the particular facts surrounding
the violation can create a “ confluence of
factors” that can result in an ignition. Texas g ulf , Inc. , 10
FMSHRC 498, 501 (Apr. 1988). These factors include “a sufficient concentration of
methane in the atmosphere . . . and ignition sources.” Id . The confluence
of factors can create a fire and/or explosion. Id . In this case, the Secretary
asserts that there was a confluence of factors that created a fire hazard. Tr. II
29-30. As previously noted, Monongalia does not dispute that the subject accumulation
violation was properly designated as S&S. However, the Secretary does not assert
that the cited accumulations created a propagation hazard given their distance from
the face. Id . at 30-31; Sec’y Post-Hr’g Br. at 18.
b. Unwarrantable Failure
The Commission
summarized the characteristics of an unwarrantable failure in IO Coal
Co. , 31 FMSHRC 1346 (Dec. 2009). The Commission
stated:
The unwarrantable failure terminology is
taken from section 104(d) of the Act, 30 U.S.C. § 814(d), and refers to more serious
conduct by an operator in connection with a violation. In Emery Mining Corp. ,
9 FMSHRC 1997 (Dec. 1987), the Commission determined that unwarrantable failure
is aggravated conduct constituting more than ordinary negligence. Id . at
2001. Unwarrantable failure is characterized by such conduct as “reckless disregard,”
“intentional misconduct,” “indifference,” or a “serious lack of reasonable care.”
Id . at 2003-04; Rochester & Pittsburgh Coal Co. , 13 FMSHRC 189,
194 (Feb. 1991); see also Buck Creek Coal, Inc. v. MSHA , 52 F.3d 133, 136
(7th Cir. 1995) (approving Commission's unwarrantable failure test).
Id . at 1350.
Thus, whether conduct is “aggravated” in the context
of unwarrantable failure is determined by considering the facts and circumstances
of each case to determine if aggravating or mitigating factors exist. Id .
at 1351. These factors include: (1) the extent of the violative condition, (2)
the length of time that the violative condition existed, (3) whether the violation
posed a high degree of danger, (4) whether the violation was obvious, (5) the operator's
knowledge of the existence of the violation, (6) the operator's efforts in abating
the violative condition, and (7) whether the operator had been placed on notice
that greater efforts were necessary for compliance. See id . at 1350-51; Cyprus
Emerald Res. Corp ., 20 FMSHRC 790, 813 (Aug. 1998), rev'd on other grounds ,
195 F.3d 42 (D.C. Cir. 1999) . These factors must
be viewed in the context of the factual circumstances of a particular case. Consolidation
Coal Co. , 22 FMSHRC 340, 353 (Mar. 2000). Accordingly, Commission judges are
not required to give equal weight to the above factors. Emery Mining Corp ., 9 FMSHRC 1997,
2001(Dec. 1987). Thus,
the unwarrantable failure question is resolved based on whether there are mitigating
factors that outweigh any aggravating factors. As discussed below, although the
aggravating factors outnumber the mitigating factors, the weight given to the mitigating
factors precludes a finding of an unwarrantable failure.
i.
Obviousness and Extent of the Violative Condition
Turning to the relevant
factors identified by the Commission, with respect to obviousness and extent, the
accumulations were readily observable given the 1/8 inch in depth of coal dust that
was deposited on “the mine roof, ribs, belt structure, [and in] multiple crosscuts”
in the
5 West No.1 belt entry for a length of approximately
3400 feet. Tr. I 107. In addition to the
1/8-inch depth of accumulations, there were
10 discrete locations, each measuring approximately three feet long by three feet
wide, where the accumulations measured 16 to 24 inches in depth. Id . at 104-06.
At these locations there were a total of 19 rollers turning in coal. Id .
at 107. Thus, these locations totaled approximately 33 feet in length. Id .
at 79, 109, 200; see also Sec’y Exs. 1, 8, 45. The discrete areas of
greater accumulations apparently were significantly affected by the misaligned belt
at the 27 block. Sec’y Ex. 6; Resp’t Ex. 4.
However, there were
only two malfunctioning rollers out of the approximately 4000 properly functioning
rollers that were operating within the 3400-foot expanse inspected by Peddicord
in the belt entry. Id . at 199-200. Similarly, there was only approximately
50 feet of misaligned belt in the vicinity of the 27 block out of 3400 feet of beltline
inspected by Peddicord. Tr. I 199-201. The misaligned rollers and malfunctioning
belt were located a distance of approximately three-and-a-half miles from the working
face. Id . at 167. Although the potential ignitions sources relied on by the
Secretary were less obvious, on balance, the obvious nature and extent of the accumulations
are aggravating factors. See E. Assoc. Coal Corp. , 32 FMSHRC
1189, 1195 (Oct. 2010) (citing Peabody Coal Co. , 14 FMSHRC 1258, 1261 (Aug.
1992)); Quinland Coals, Inc. , 10 FMSHRC 705, 708 (June 1988).
ii.
Duration of the Violative Condition
Monongalia’s
self-serving assertion that a significant portion of the cited accumulations occurred
as a result of broken conveyor chains that purportedly occurred only hours before
Peddicord’s inspection is unavailing. Resp’t Post-Hr’g Br. at 40. Rather, I credit
Peddicord’s testimony that a substantial portion of the accumulations existed for
at least three shifts. Tr. I 135. I reach this conclusion based on the extensive
nature of the accumulations as well as Peddicord’s observation of footprints tracking
through the accumulations, which is further evidence of their duration. Id .
at 136. Moreover, the preshift examination records further support Peddicord’s opinion
that the accumulations existed for at least several shifts. Resp’t. Ex. 25. Namely,
the examination book reflects relevant accumulations located in the 5 West No. 1
belt entry, from the 25 block to the 34 block, that were noted during the preshift
examination conducted from 1:00 p.m. to 3:00 p.m. on July 29, 2014. Id . This
preshift examination was conducted three shifts prior to the issuance of Order No.
8059209 at 9:30 a.m. on July 30, 2014. Resp’t. Ex. 25.
In addition,
the misaligned belt observed by Peddicord caused the belt conveyor to rub against
six bottom roller cradles, all of which were covered by coal dust. Tr. II 69. The
continued rubbing between the belt conveyor and cradles created friction sufficient
to remove the top coating of paint from all six cradles revealing a “shiny metal”
surface. Id . at 117. The friction-related damage reflects that the accumulations
in the cradles developed over a significant period of time. Id . Peddicord’s observation
of friction-related damage in the areas of these accumulations also undermines Monongalia’s
assertion that these accumulations had recently occurred. Resp’t Post-Hr’g Br. at
- Consequently, the record supports the Secretary’s contention that the cited
accumulations existed for at least several shifts, and, as such, is an aggravating
factor.
iii.
Operator’s Knowledge of the Violative Condition
The Commission has
held that knowledge is established by showing the failure of an operator to abate
a violation that it knew or reasonably should have known existed. See
Emery Mining , 9 FMSHRC at 2002-03; IO Coal , 31 FMSHRC at 1356-57
(holding that an operator “reasonably should have known of a violative condition”);
Drummond Co. , 13 FMSHRC 1362, 1367-68 (Sept. 1991) (quoting Eastern Assoc.
Coal Corp. , 13 FMSHRC 178, 187 (Feb. 1991)).
As noted, Monongalia
had knowledge of the cited accumulations as reflected by the preshift examination
records that recorded relevant accumulations from the 25 to the 34 block in the
preshift examination conducted during the afternoon shift on July 29, 2014. Resp’t.
Ex. 25. Moreover, it is reasonable to conclude that belt examiners had previously
observed the subject accumulations as evidenced by Peddicord’s testimony of footprints
in the accumulations located in the inspected area. Tr. I 136. Thus, Monongalia’s
actual or constructive knowledge of the cited accumulations is an aggravating factor
that weighs in favor of finding an unwarrantable failure.
iv.
Operator’s Notice that Greater Compliance Efforts Are Required
The Commission has
noted that repeated similar violations can constitute an aggravating factor that
is relevant to an unwarrantable failure determination in that they serve to put
an operator on notice that greater efforts are necessary for compliance with the
cited standard. See IO Coal , 31 FMSHRC at 1353-55; Amax Coal Co. ,
19 FMSHRC 846, 851 (May 1997); see also Consolidation Coal Co. , 23
FMSHRC 588, 595 (June 2001). Thus, a relevant excessive history of similar violations
is a significant element of an unwarrantable failure designation. In this case,
Monongalia had been cited for 147 violations of section 75.400 in the two years
preceding the issuance of the subject accumulation violation. Sec’y Ex. 39. Based
on this fact alone, it is clear that Monongalia was aware that greater compliance
efforts were required for its adherence to the mandatory safety standard in section
75.400.
The Commission has
also recognized that “past discussions with MSHA” about a problem “serve to put
an operator on heightened scrutiny that it must increase its efforts to comply with
the standard.” San Juan Coal , 29 FMSHRC 125, 131 (Mar. 2007) (citing Consolidation
Coal , 23 FMSHRC at 595). Peddicord testified that in addition to the subject
accumulation violation citation issued on July 30, 2014, there were two additional
similar accumulation violation citations issued in April and May of 2014. Tr. I
140-41. Peddicord further testified without contradiction that during closeout conferences,
mine inspectors counsel mine operators on how to best avoid the future occurrence
of similar violations. Id . at 141. As previously noted, in recognition of
its belt problems, Monongalia reportedly made significant upgrades and capital improvements
to the 5 West No. 1 belt “to enhance the tracking . . . [in an effort] to reduce
spillage in and along the beltlines and drive areas.” Tr. III 54-56; Resp’t Ex.
- Thus, Monongalia’s significant history of relevant violations, its relevant
capital expenditures, and its prior closeout conferences with MSHA clearly demonstrate
that it was on notice that greater efforts were required to avoid accumulation violations
of section 75.400.
v.
Operator’s Efforts in Abating the Violative Condition
When considering
a mine operator’s efforts to eliminate the subject violative condition, the Commission
focuses on compliance efforts made prior to the issuance of a citation or order.
Enlow Fork Mining , 19 FMSHRC 5, 17 (Jan. 1997). The 5 West No. 1 belt extends
in an outby direction from the headpiece at the 59 block to the tailpiece at the
1 block. Sec’y Ex. 45. This matter concerns accumulations cited by Peddicord from
the 6 block to the 34 block in the 5 West No. 1 belt entry. Sec’y Ex. 1. The preshift
and on-shift reports for the 5 West No. 1 belt preceding the preshift examination
conducted from 5:00 a.m. to 7:16 a.m., immediately prior to Peddicord’s inspection
at 9:00 a.m. on July 30, 2014, are instructive. The notations in these reports reflect
corrective actions for numerous accumulation-related conditions concerning bad top
and bottom rollers and broken chains. Resp’t Ex. 25. The examination records also
reflect notations for spillage and accumulations in need of cleaning or rock dusting.
Id . Many of the accumulation-related conditions were beyond the area inspected
by Peddicord, located from the 41 block to the 59 block. Id . As
a general proposition, these notations and corrective actions reflect that the operating
conditions in the 5 West No. 1 belt entry were not being ignored. Id .
More specifically,
the examination reports reflect notations and corrections taken immediately prior
to the subject inspection in the area observed by Peddicord. Id . For example,
during the preshift examination conducted from 9:00 p.m. to 11:00 p.m. on July 29,
2014, a bad top roller located at the 22 block was noted in addition to dark gray
accumulation present from the 25 block to the 34 block. Id . The midnight
on-shift report of July 30, 2014, reflects corrective action for broken chains located
at the 36, 37, and 39 blocks. Id . Although Peddicord observed a hot roller
at the 7 block and a frozen roller at the 29 1/2 block, his observations did not
include a bad top roller located at the 22 block or broken chains at the 36, 37,
or 39 blocks. Sec’y Ex. 3. Consequently, Peddicord’s failure to cite these
conditions leads to the reasonable conclusion that corrective actions may have been
taken immediately prior to Peddicord’s inspection.
Although Monongalia’s
efforts to prevent the subject accumulation violation were unsuccessful, it is apparent
remedial actions were being taken during the shifts immediately preceding the subject
inspection. Resp’t Ex. 25. Thus, I view Monongalia’s attempt to improve the accumulation
conditions in the 5 West No. 1 belt entry prior to Peddicord’s inspection as a mitigating
factor.
vi.
Degree of Danger Posed by the Violative Condition
The degree of hazard
posed by accumulation violations must be viewed in the context of the fact that
fire, smoke, and the danger of an explosion are the natural consequences of combustion.
The D.C. Circuit held that the existence of an emergency should be assumed in evaluating
the degree of hazard for determining whether a violation is properly designated
as S&S. Cumberland Coal Res., LP , 717 F.3d 1020, 1024 (D.C. Cir. 2013)
(holding that an emergency necessitating an evacuation should be assumed in evaluating
whether an improperly hung lifeline constitutes an S&S violation). However,
to assume the occurrence of a fire-related emergency to determine whether a violation
constitutes an unwarrantable failure would conflate S&S designations with unwarrantable
failures, thus rendering the majority of section 75.400 violations as unwarrantable.
Such a result is problematic as section 75.400 is the most commonly cited mandatory
safety standard. For example, in the year 2014, section 75.400 violations comprised
10.73% of all cited mandatory safety standards. Resp’t Ex. 15; Most Commonly
Cited Standards , MSHA, supra page 11. Rather, a reasoned analysis should
be employed to distinguish those accumulation violations that are unwarrantable
from those that are not.
As previously noted,
in Texas g ulf the
Commission noted the degree of hazard associated with a section 75.400 violation
is based on an inquiry as to whether the circumstances surrounding the cited combustible
accumulations create a confluence of factors, such as explosive levels of methane
in proximity to ignition sources that can cause a fire or explosion. See
10 FMSHRC at 501.
With respect to a confluence of factors, it is important to distinguish accumulations
remotely located in belt entries from those that pose a propagation risk by virtue
of their proximity to working places where mining crews are present and dangerous
levels of methane and ignition sources are more prevalent. [9]
The Commission’s
decision in Twentymile is instructive in illustrating the significance of
the location of accumulations. Twentymile Coal Co. , 36 FMSHRC 1533 (June
2014). In Twentymile , the Commission considered the gravity of two separate
violations of section 75.400. Id . The first violation concerned black coal
dust accumulations and dark float coal dust located in the tailgate extending 1700
feet outby into a return entry. Id . at 1534. The Commission concluded that
the subject accumulations were S&S in nature because “there was ample reason
to fear a methane ignition at the face” that would propagate an explosion fed by
the dangerous accumulations of float coal dust. Id . at 1536.
The second violation
in Twentymile concerned accumulations near the portal in the belt entry extending
3400 feet inby. Id . at 1540. The accumulations of coal dust were “very fine”
in nature. Id . These accumulations were located approximately seven miles
from the longwall face. Id . at 1543. The judge concluded that the accumulations
were S&S because “a methane explosion at the [longwall] face can travel ‘long
distance[s]’ down mine entries, ‘for a considerable distance beyond the presence
of the methane.’” Id . at 1543 (quoting Twentymile Coal Co ., 32 FMSRC
1431 (Oct. 18, 2010) (ALJ)). The Commission vacated the S&S designation based
on its finding that “[t]here [was] no record evidence that the explosive forces
would travel so far in the mine in question,” and remanded the S&S issue for
further consideration. Id . at 1543, 1544.
Here, risk posed
by the potential ignition sources relied on by the Secretary cannot be disassociated
from degree of danger posed by the cited accumulations. The Secretary has attributed
the degree of negligence for the defective rollers and misaligned belt in Citation
Nos. 8059210 and 8059211 to moderate and low negligence, respectively. Sec’y Exs.
3, 4. The
Secretary proposed civil penalties
of $1203.00 for the malfunctioning rollers and $585.00 for the misaligned belt.
Sec’y Ex. 5. These citations were the subjects of a Joint Motion to Approve Settlement
that was approved in a December, 22, 2015, Decision Approving Settlement in Docket
No. WEVA 2015-0033, which required Monongalia to pay the proposed penalties.
Sec’y Ex. 4; Tr. I 116. The Secretary’s
attribution for the unaddressed potential ignition sources to only low or moderate
negligence undermines the unwarrantable failure designation. It is true that the
Commission in Twentymile affirmed the unwarrantable failure for the remotely
located accumulations near the portal. 36 FMSHRC at 1546. However, Twentymile
is distinguishable in that it did not involve the presence of violative ignition
sources that have been attributed to low and moderate negligence, and for which
the Secretary has proposed relatively low civil penalties.
In this case, although
Monongalia has stipulated to the fact of the accumulation violation, the Secretary
has admitted that the cited accumulations located approximately three-and-a-half
miles from the face did not constitute a propagation hazard. Sec’y Post-Hr’g Br.
at 4-5; Tr. I 78. Thus, the Secretary has, in effect, conceded that the danger posed
by the cited accumulations was less than it would have been had the accumulations
posed a propagation risk.
While I may have
favorably entertained a timely motion to amend Citation Nos. 8059210 and 8059211
with respect the degree of negligence alleged, the Secretary failed to do so. In
the absence of a showing of prejudice, had the Secretary filed a timely motion,
I may have been inclined to find an unwarrantable failure.
Despite the rather
de minimis penalty for the defective roller and misaligned belt, the Secretary now
seeks to impose a civil penalty of $121,300.00 for the subject accumulations cited
in Order No. 8059209. Resp’t Ex. 6. Notwithstanding the absence of a propagation
hazard, the Secretary’s attribution of a relatively low degree of negligence attributable
to Monongalia’s failure to address the potential ignition sources relied on by the
Secretary undermines his assertion that the accumulations are attributable to aggravated
conduct. Resp’t Exs. 2, 3; Sec’y Ex. 6.
Despite the distance
of the accumulations from the face, Monongalia cannot escape the fact that the accumulation
conditions in the 5 West No. 1 belt entry were obvious, known, and extensive. Moreover,
Monongalia was on notice that greater efforts were necessary for compliance given
the capital expenditures it incurred to address accumulation problems in its Monongalia
County Mine. Consequently, the Secretary has demonstrated that the cited accumulations
are attributable to Monongalia’s high degree of negligence.
However, it is not
uncommon for the Secretary to issue 104(a) citations, rather than 104(d) citations,
for violations that are attributable to a mine operator’s high degree of negligence.
See Original Sixteen to One Mine, Inc ., 36 FMSHRC 2224, 2229 (Aug. 2014)
(ALJ) (upholding the inspector’s issuance of a 104(a) citation due to the operator’s
high degree of negligence); Taft Production Co ., 35 FMSHRC 965, 971 (Apr.
2013) (ALJ) (upholding the inspector’s issuance of a 104(a) citation due to the
operator’s high degree of negligence); Black Beauty Coal Co ., 34 FMSHRC 1733,
1574-5 (Aug. 2012) (remanding an ALJ’s affirmation of an unwarrantable failure designation);
Black Beauty Coal Co ., 35 FMSHRC 401, 410 (Feb. 2012) (ALJ) (finding the
violation was due to an operator’s high negligence but did not constitute an unwarrantable
failure); Bachman Sand and Gravel , 34 FMSHRC 226, 233 (Jan. 2012) (ALJ) (modifying
a 104(d)(1) citation issued due to the operator’s high degree of negligence to a
104(a) citation at hearing); Cloverlick Coal Co , 31 FMSHRC 1377, 1381 n.2
(Nov. 2009) (ALJ) (modifying a 104(d)(1) order issued due to the operator’s high
degree of negligence to a 104(a) citation).
Although the subject
accumulations are attributable to a high degree of negligence, the issue is whether
Monongalia’s conduct can be properly characterized as aggravated or indifferent.
The relevant preshift examination records for the shifts preceding Peddicord’s inspection
on the morning of July 30, 2014, fail to reveal a level of indifference. Rather,
they reflect that Monongalia took actions, albeit unsuccessfully, to address the
accumulation conditions in the 5 West No. 1 belt entry. Resp’t Ex. 25. Consequently,
consistent with Commission case law, although Monongalia’s negligence was high,
the Secretary has failed to demonstrate that it rose to the level of aggravated
or unjustified conduct indicative of an unwarrantable failure. Accordingly, Order
No. 8059209 shall be modified to a 104(a) citation to reflect that the cited accumulation
violation is not unwarrantable.
c.
Flagrant
Congress provided
a not so subtle clue for the proximate cause requirement for imposition of enhanced
civil penalties by specifying what a flagrant violation means. Section 110(b)(2)
provides:
[T]he
term “flagrant” with respect to a violation means a reckless or repeated
failure to make reasonable efforts to eliminate a known violation of a mandatory
safety standard that substantially and proximately caused, or reasonably could
have been expected to cause, death or serious bodily injury.
30 U.S.C. § 820(b)(2) (emphasis added).
Prior to the passage
of section 110(b)(2), the most severe sanction under the Act was a withdrawal order
issued pursuant to section 104(d) that subjects an operator to a maximum penalty
of $70,000.00. [10]
Greenwich Colleries , 12 FMSHRC 940, 945 (Nov. 2011) (citing UMWA v. FMSHRC ,
768 F.2d 1477, 1479 (D.C. Cir. 1985)); 30 U.S.C § 814(d). Withdrawal orders are
issued solely as a consequence of an operator’s unwarrantable conduct evidencing
more than ordinary negligence, without regard to the degree of hazard posed by the
subject violation. Thus, 104(d) withdrawal orders can be issued for non-S&S
violations.
Similar to the provisions
of section 104(d), the flagrant provisions amended the Mine Act to allow for the
imposition of enhanced civil penalties for dangerous violations that are attributable
to reckless or repeated conduct, also demonstrating more than ordinary negligence.
30 U.S.C. § 820(b)(2). However, unlike section 104(d) withdrawal orders, which may
be issued for non-S&S violations that do not pose a high degree of danger, Congress
added the “proximate cause” and “death or serious bodily injury” provisions as prerequisites
for a flagrant designation. Id . Consistent with the Mine Act’s graduated
enforcement scheme, section 110(b)(2) provides for enhanced civil penalties for
flagrant violations of up to $220,000.00, adjusted for inflation. Id ; Nat’l
Gypsum Co. , 3 FMSHRC at 828 (holding that the Mine Act provides for
increasingly severe sanctions for increasingly severe violations).
In American Coal ,
the Commission remanded a Judge’s flagrant analysis of an accumulation violation
for further consideration of the application of the Commission’s “narrow” and “broad”
interpretations of section 110(b)(2) of the Act. 38 FMSHRC at 2085. As noted, if
appropriate, the Commission directed the Judge “to fashion an interpretation of
the flagrant violation provision . . . which permits the Secretary to establish
a violation as flagrant by taking the operator’s history of previous accumulation
violations into account.” Id . at 2082. On remand, the judge found the subject
accumulation violation satisfied the flagrant provision under a “narrow” analysis.
American Coal Co ., 39 FMSHRC 1247, 1265 (June 15, 2017) (ALJ). Thus, the
Commission’s “broad” interpretation with respect to “repeated” flagrant designations
for accumulation violations remains unresolved. While I am adjudicating the propriety
of the “repeated” flagrant designation under the “narrow” approach, I will endeavor
to address the differing relevant considerations associated with a “narrow” and
“broad” analysis that uniquely apply to accumulation violations.
In American Coal ,
the Commission chose to rely on the degree of negligence demonstrated by an operator’s
failure to address a known violation rather than “the degree of danger posed by
a violation,” to distinguish a flagrant violation. 38 FMSHRC at 2070. However, the
Commission could not have intended to disregard two inviolate principles of law.
The first is that it is axiomatic that the degree of danger posed by a hazard and
the degree of care required to avoid that hazard are inextricably intertwined. In
other words, the duty to remedy increasingly dangerous conditions requires an increasingly
higher standard of care. See Peklun v. Tierra Del Mar Condominium Assc .,
119 F.Supp.3d 1361(S.D. Fla. 2015); Manchenton v. Auto Leasing Corp ., 605
A.2d 208 (N.H. 1992); Richardson v. Gregory , 281 F.2d 626 (D.C. Cir 1960);
Palsgraf v. Long Island R.R. Co. , 162 N.E. 99 (1928).
The second inviolate
principle is that “proximate cause,” as contemplated by section 110(b)(2) of the
Act, is “[a] cause that directly produces an [injury] and without which the [injury]
would not have occurred.” Black’s Law Dictionary
213 (7 th ed. 1999). In keeping with these principles, the flagrant provisions
of the Act are intended to address the most dangerous of violations – those that
are known yet remain unabated despite the fact that they can be reasonably expected
to proximately cause death or serious bodily injury.
The Commission tracked the provisions of
section 110(b)(2) in identifying the elements for establishing a flagrant violation.
These elements are:
(1) there was a condition that
constituted a violation of a mandatory health or safety standard, (2) the violation
was “known” by the operator; (3) the violation either (a) substantially [and proximately]
caused death or serious bodily injury, or (b) reasonably could have been expected
to [substantially and proximately] [11] cause death or serious bodily injury;
(4) there was a failure on the part of the operator to make reasonable efforts to
eliminate the violation; and (5) that failure was either reckless or repeated.
American Coal , 38 FMSHRC at 2066-67.
With the exception
of the “repeated” criterion in element number five, the Commission did not differentiate
between the remaining elements necessary for demonstrating a “repeated” flagrant
violation under a “narrow” analysis from those required under a “broad” analysis.
Id . Thus, with the exception of “repeated,” the remaining statutory provisions
of section 110(b)(2) apply to both a “broad” and “narrow” approach. A “narrow” analysis
is a traditional application of statutory provisions to the facts surrounding a
discrete alleged violation. It is only when the alleged flagrant violation is neither
“reckless” nor “repeated” under a traditional analysis that a history of violations
may become material in designating a violation as “repeated flagrant.” [12]
i.
Narrow Interpretation
Turning to the Commission’s
elements with respect to a “narrow” interpretation, element one is satisfied as
the accumulations constituted a violation as reflected by their nature and extent
as well as Monongalia’s stipulation. As previously discussed, the evidence reflects
element two with respect to knowledge is satisfied by virtue of the footprints in
the accumulations and notations in the preshift examination records. Resp’t Ex.
25; Tr. I 136. That Monongalia failed to make reasonable efforts to eliminate the
violative accumulations despite being aware of them satisfies element number four.
Resp’t Ex. 25.
Thus, the remaining
elements for a “narrow” flagrant violation require an analysis of the term “repeated”
in element five and the term “proximate cause” in element three, as contemplated
by the statue. In addressing a “narrow” interpretation of the term “repeated” based
on a repeated failure to address violative accumulations, it is helpful to distinguish
between section 75.400 violations that concern accumulations that by nature occur
over a period of time from spillage that occurs spontaneously.
Section 75.400 provides:
Coal dust, including
float coal dust deposited on rock-dusted surfaces, and other combustible materials,
shall be cleaned up and not be permitted to accumulate in active workings,
or on diesel-powered and electrical equipment therein.
30 C.F.R. § 75.400 (emphasis added).
As a general proposition,
while the Mine Act is a strict liability statute, strict liability cannot
create liability for conduct that does not otherwise violate a mandatory safety
standard.
Pragmatically speaking, accumulations of
coal dust and coal fines that occur over a period of less than one shift may not
constitute a violation of section 75.400. I reach this conclusion for two reasons.
Such accumulations of coal particles that have occurred over a brief period of time
may not be of sufficient depth to require rock dusting or removal. Obviously, there
must be a minimum depth requirement to constitute a violation of section 75.400.
Assuming the bare minimum depth of such short-term accumulations is sufficient to
require removal, the Secretary would have difficulty demonstrating that the operator
“permitted” the accumulations to occur in that the operator may not have had a reasonable
period of time to address them.
However, Monongalia’s
stipulation to the fact of the violation constitutes its admission that it permitted
the combustible accumulations to occur without addressing them within a reasonable
period of time. Notwithstanding the stipulation, the evidence reflects that the
subject accumulations existed for at least three shifts based on the nature and
extent of the accumulations, the notations in the preshift examination reports,
as well as Peddicord’s observation of footprints left in the accumulations. Resp’t
Ex. 25; Tr. I 136. Having existed for at least three shifts, the accumulations
satisfy the “narrow” interpretation of “repeated” based on the duration of the subject
accumulations, without regard to a history of relevant similar violations that are
necessary under the “broad” approach.
Having determined
that the duration of the accumulations satisfies the “repeated” fifth element under
the “narrow” approach, we turn to the issue of proximate cause under the third element.
The proximate cause element is essential in demonstrating a flagrant accumulation
violation. Thus, the focus shifts to whether the violative accumulations could be
reasonably expected to cause a fire that will “proximately cause death or serious
bodily injury.” As previously noted, the D.C. Circuit has concluded that an underground
mine fire caused by violative accumulations should be assumed in evaluating whether
the violation is properly designated as S&S. Cumberland Coal , 717
F.3d at 1027. However, the question is whether this
presumed fire gives rise to an assumption that the fire is reasonably expected to
substantially and proximately cause death or serious bodily injury, as required
by statute.
In American Coal ,
the Commission concluded that a potential injury from smoke inhalation as a result
of a mine fire constitutes “a serious bodily injury” as contemplated by the flagrant
provisions. 38 FMSHRC at 2070. However, the flagrant provisions require a showing
that serious smoke inhalation injury or death is “reasonably expected” to occur.
30 U.S.C. § 820(b)(2). The distinction between the likelihood of the occurrence
of a “lost workday” injury and a “permanently disabling” or “fatal” injury with
respect to smoke inhalation requires consideration of the location of the victim.
For while fires produce smoke, not all fires pose a significant risk of grave smoke
inhalation injuries. To assume otherwise would render the majority of frequently
cited violations of section 75.400 as flagrant.
The history of fatal
or serious injuries associated with belt fires reflects that victims were located
in working places where mine crews were assigned as distinguished from injuries
to belt examiners traveling in entries located in remote areas of the mine. There
were 65 reportable fires from 1980 to 2007, nearly all of which involved mine conveyor
belts. Flame-Resistant
Conveyor Belt, Fire Prevention and Detection, and Use of Air from the Belt Entry , 73 Fed. Reg. 80,580,
80,606 (Dec. 31, 2008) [ herein after Conveyor Belt Rulemaking]. During this
27-year period, these fires resulted in three deaths and approximately two dozen
injuries. Id .
Of the three deaths,
two occurred at the Aracoma Alma No. 1 Mine on January 19, 2006. Mine Safety and Health Admin., U.S. Dep’t of Labor
Report of Investigation Fatal Underground Coal Mine Fire Aracoma Alma Mine #1
(2007). [13]
The deaths occurred when a twelve-member crew performing roof-bolting and assorted
tasks in a return entry attempted to escape smoke emanating from a longwall belt
takeup storage unit in the headgate by entering the primary escapeway. Id .
7, 9-10. However, missing stoppings caused the primary escapeway to be inundated
with thick black smoke. Id . at 36-37. Ten of the crewmembers escaped the
mine by entering into a personnel door that allowed them to access the secondary
escapeway.
Id . at 12. However, the two fatalities
occurred when the victims became disoriented and
continued to travel in the primary escapeway
toward the origin of the smoke. Id . at 12-13. The remaining fatality
occurred at the Florence No. 1 Mine on November 27, 1986, when a mine foreman suffered
a fatal heart attack while fighting a belt fire. Conveyor Belt Rulemaking, 73 Fed.
Reg. at 80,606.
The remaining relevant
accumulation-related fatalities occurred at the Upper Big Branch Mine on April 5,
2010. Mine Safety and Health Admin., U.S.
Dep’t of Labor, Report of Investigation Fatal Underground Mine Explosion Upper Big
Branch Mine-South 1 (2010). The fatalities occurred as a result of a methane
ignition located near a longwall tailgate. Id . at 2. The ignition
was caused by worn shearer bits that likely created an ignition source when the
shearer came into contact with sandstone. Id . at 7. The initial methane ignition
at the tailgate ignited a larger accumulation of methane that caused a massive explosion
engulfing an extremely large area of the mine. Id . As a consequence, 29 miners
lost their lives. Id .
As a result of its
investigation, MSHA concluded the Upper Big Branch Mine disaster was attributable
to violations of a variety of safety standards. Id . at 4-10. These
violations included, inter alia, performing perfunctory mine examinations; failing
to maintain the longwall shearer in satisfactory condition creating an ignition
source for accumulated methane; and failing to remove or rock dust extensive areas
of coal dust accumulated throughout the mine, which provided the fuel source for
a massive explosion. Id . at 9. The investigation also determined that the
mine operator’s failure to abide by its roof control and ventilation plans, contributed
to the fall of the tailgate roof, which in turn restricted airflow to the longwall
face. Id . at 6. The reduced airflow permitted dangerous levels of methane
to accumulate in the tailgate without being diluted. Id .
The fatal belt fire
at Aracoma and the fatalities caused by the massive explosion at Upper Big Branch
are distinguishable from the risk posed to a belt examiner who is inspecting conveyors
in remote areas of a mine. Rather, the smoke inhalation risk posed to belt examiners
is a matter of degree. Belt entries are ventilated with fresh air. Tr. I 129;
Conveyor Belt Rulemaking 73 Fed. Reg. at 80591. A belt examiner traveling in an
outby direction, approaching the cited accumulations, would become aware of any
smoky conditions prior reaching the origin of the fire, thus avoiding significant
exposure to smoke emanating from the cited accumulations. Similarly, a belt examiner
traveling in an inby direction would not be exposed to a significant risk of serious
smoke inhalation as any smoke would be carried away from him in an inby direction.
The greatest risk of a significant smoke inhalation injury to a belt examiner is
if the examiner happened to be at the location of the cited accumulations at the
moment of ignition, a circumstance that is not “reasonably expected” to occur. Finally,
any belt maintenance performed by mine crews in the belt entry would require de-energizing
the conveyor, thus eliminating the risk of fire. 30 C.F.R. § 75.511.
The Commission
has noted the Secretary’s citation characterizations of “lost workdays or restricted
duty,” “permanently disabling,” and “fatal” cannot be relied upon by operators “to
circumscribe the definition of ‘serious bodily injury’ . . . in interpreting the
flagrant penalty provisions.” American Coal , 38 FMSHRC at 2069 (citing Brody
Mining, LLC , 37 FMSHRC 1687, 1701 (Aug. 2015)). So too, the Commission is not
bound by the degree of negligence attributed to mine operators by the Secretary.
Id . at 2083. Rather, the Commission’s negligence determinations should be
based upon “the totality of the circumstances holistically.” Id . at 2083,
(quoting Brody Mining , 37 FMSHRC at 1702). Thus, Commission judges retain
the de novo discretion, based on the particular circumstances of a case, to credit
or reject the gravity and/or negligence characterizations in contested citations.
In this case, that
potentially deadly smoke inhalation should not be presumed regardless of the location
of the combustible accumulations, is illustrated by the Secretary’s citations for
the non-functioning rollers and misaligned belt. These citations reflect that the
potential ignition sources exposed the belt examiner to no more than injuries that
would result in lost workdays or restricted duty. Sec’y Exs. 3, 4. Thus, the Secretary,
in essence, acknowledges that accumulations located in belt entries several miles
from working sections may not pose a significant smoke inhalation risk.
Here, the subject
accumulations are approximately three-and-a-half miles from the working section
where mining crews are assigned. Tr. II 167-68. I
do not construe the Commission’s express concern over the serious consequences of
smoke inhalation to apply to situations where the combustible accumulations are
remotely located in belt entries many miles from the working face, where serious
or fatal injuries are not reasonably expected to occur. Consequently, the evidence,
when viewed in its entirety, reflects that the Secretary has failed to satisfy his
burden of demonstrating that a fire caused by the cited accumulations could be reasonably
expected to proximately cause death or serious bodily injury to a belt examiner.
Therefore, the flagrant designation shall be deleted.
Make no mistake.
I am not trivializing the inhalation risk to miners in general and to belt examiners
specifically. However, despite MSHA’s well-meaning intentions, confidence in the
implementation of the Act is undermined by attempts to broaden the reach of the
statutory flagrant provisions provided by Congress. See Drummond Co. ,
14 FMSHRC 661, 674-75 (May 1992) (holding that the Commission’s adjudicative powers
are a means to enhance public confidence in the implementation of the Mine Act).
I am only suggesting that Congress could not have contemplated that the majority
of frequently cited section 75.400 violations should be designated as flagrant simply
by assuming grave smoke inhalation injuries occurring as a consequence of an assumed
fire without due regard to the specifics of a particular case.
ii.
Broad Interpretation
Spillage, by nature,
occurs suddenly. Consequently, a spillage violation may not satisfy the Commission’s
“narrow” duration criteria for a “repeated” flagrant violation. Under the Commission’s
broad approach, an accumulation violation may be designated as a “repeated” flagrant
violation based on a relevant history of similar violations. While a history of
violations is one of many considerations in an unwarrantable failure analysis, consistent
with Wolf Run , as elaborated in American Coal , a relevant
recurrent history of violations may provide the sole basis for a “repeated” designation
of a spillage violation under a “broad” analysis. Under such circumstances, Monongalia’s
147 violations of section 75.400 in the two years preceding the issuance of a citation
for an alleged spillage violation may constitute the requisite recurrent history
under a broad analysis.
On the other hand,
virtually all coal dust accumulation violations that are not caused by spillage
satisfy the “narrow” “repeated” element because they must have developed and gone
unaddressed for at least more than one shift. Consequently, the question of whether
violative accumulations not caused by spillage can be a “repeated” flagrant violation
under the “broad” approach is moot.
Notwithstanding the
moot nature of the “broad” analysis, in American Coal the Commission sought
the Judge’s input with respect to fashioning the criteria for a “broad” analysis
of the “repeated” provision as it applies to accumulation violations. 38 FMSHRC
at 2082. In this case, rather than relying on a general history of violations, the
Secretary asserts that “predicate” violations that satisfy the requirements for
a flagrant violation, but have not been designated as flagrant, [14] may serve as
the basis for demonstrating a “repeated” flagrant violation under a “broad” analysis. [15] Sec’y Post-Hr’g
Br. at 46-47.
The Commission has
the unquestioned adjudicative authority to resolve disputes concerning the validity
of enforcement actions. Freeman United Coal Co ., 6 FMSHRC 1577, 1580-81 (July
1984). In addressing its adjudicative function, the Commission has stated:
The Mine Act expressly empowers the Commission
to grant review of “question[s] of law, policy or discretion,” and to direct review
sua sponte of matters that are “contrary to … Commission policy” or that
present a “novel question of policy….” Since Congress authorized the Commission
to direct such matters for review, we infer that Congress intended the Commission
to possess the necessary adjudicative power to resolve them. The reason the Commission
was created by Congress and equipped with broad remedial powers and policy jurisdiction
was to assure due process protection under the statute and, hence, to enhance public
confidence in the mine safety and health program. Addressing claims of arbitrary
enforcement by the Secretary is at the heart of [the Commission’s] adjudicative
role.
Drummond Co. , 14 FMSHRC at 674-75
(emphasis added) (footnote omitted) (citations omitted). Consistent with Drummond ,
section 706(2)(A) of the Administrative Procedure Act (“APA”) requires setting aside
agency action that is arbitrary, capricious, or an abuse of discretion.
5 U.S.C. § 706(2)(A).
Although the Commission
has concluded that a “broad” analysis is a viable option, the Secretary’s reliance
on predicates in a “broad” analysis must be rejected for several reasons. As an
initial matter, the Secretary’s failure to designate the purported predicate violations
as flagrant, even though they allegedly satisfy the flagrant provisions, is the
epitome of arbitrary and capricious enforcement action that must be rejected. For
it is odd that the Secretary would propose that alleged predicates that meet the
criteria for a flagrant violation, but are not designated as such, would serve as
a basis for designating a subsequent violation as flagrant even though the violation
does not otherwise meet the “reckless” or “repeated” statutory criteria.
Moreover, the Secretary
seeks to impose his “predicate” framework on mine operators without having engaged
in a relevant notice and comment rulemaking. The Commission noted in Drummond ,
that while the APA does not require adherence to the notice and comment process
for interpretive rules or general statement of policy, a formal notice and comment
rulemaking is required for agency actions that affect substantive rights. [16] 5 U.S.C. §
553; Drummond Co ., 14 FMSHRC at 690, (holding a Program Policy Letter that
that affects substantive rights requires a notice and comment rulemaking under the
APA). Clearly, the “predicate” framework that exposes operators to liability for
enhanced penalties under the flagrant provisions affects substantive rights. See
id .
Finally, and perhaps
most significantly, the Secretary has failed to successfully demonstrate a “repeated”
flagrant designation based on predicate violations despite having repeatedly attempted
to do so. In this regard, in accumulations cases before the Commission, the Secretary
has consistently sought to settle his “broad” flagrant enforcement positions by
withdrawing his “repeated” flagrant designations. See, e.g. , American Coal
Co., 40 FMSHRC 330, 332 (Mar. 2018); Oak Grove Res ., 38 FMSHRC at 964; Conshor
Mining, LLC , 37 FMSHRC 1845, 1846 (Aug. 2015) (ALJ); Wolf Run Mining Co .,
31 FMSHRC 479, 479 (Apr. 2009) (ALJ).
Most recently, in
American Coal , the Secretary agreed to amended settlement terms for
consideration by the Commission that withdraw the “repeated” flagrant designation
for an accumulations violation. Amended Jt. Mot. to Approve Settlement, Docket No.
LAKE 2009-0035 (May 18, 2018). In so doing, the Secretary agreed to a reduction
in the degree of gravity to reflect that the violation initially designated as “flagrant”
will result in no more than a “lost workday or restricted duty” injury. Id .
Having moved for the deletion of the flagrant designation, the Secretary agreed
to reduce the initial proposed penalty of $164,700.00 to $11,307.00. Id .
In an order issued June 15, 2018, the amended settlement terms deleting the
flagrant designation, reducing the level of gravity, and substantially reducing
the assessed penalty were approved by the Commission. Order, 40 FMSHRC ___
(Mar. 2018). Suffice it to say, the Secretary’s persistent removal of flagrant designations
reflects a lack of confidence in his reliance on the suitability of predicates as
a basis for demonstrating a “repeated” flagrant designation in accumulations cases.
d.
Civil Penalty
The Commission outlined
the parameters of its responsibility for assessing civil penalties in Douglas
R. Rushford Trucking , 22 FMSHRC 598 (May 2000). The Commission stated:
The principles governing the Commission's
authority to assess civil penalties de novo for violations of the Mine Act
are well established. Section 110(i) of the Mine Act delegates to the Commission
“authority to assess all civil penalties provided in [the] Act.” 30 U.S.C. § 820(i) . The Act delegates
the duty of proposing penalties to the Secretary. 30 U.S.C. §§ 815(a) and 820(a) . Thus, when an operator notifies the Secretary
that it intends to challenge a penalty, the Secretary petitions the Commission to
assess the penalty. 29 C.F.R. §§ 2700.28 and 2700.44 . The Act requires that, “[i]n assessing
civil monetary penalties, the Commission [ALJ] shall consider” six statutory penalty
criteria:
[1] the operator's history of previous violations,
[2] the appropriateness of such penalty to the size of the business of the operator
charged, [3] whether the operator was negligent, [4] the effect of the operator's
ability to continue in business, [5] the gravity of the violations, and [6] the
demonstrated good faith of the person charged in attempting to achieve rapid compliance
after notification of a violation.
22 FMSHRC at 600 (citing 30 U.S.C. § 820(i) ) . The Commission has noted that de
novo consideration of the appropriate civil penalties does not require “that equal
weight must be assigned to each of the penalty assessment criteria.” Thunder
Basin Coal Co. , 19 FMSHRC 1495, 1503 (Sept. 1997).
In keeping with this
statutory requirement, the Commission has held that “findings of fact on the statutory
penalty criteria must be made” by its judges. Sellersburg Stone Co. , 5 FMSHRC
287, 292 (Mar. 1983). Once findings on the statutory criteria have been made, a
judge’s penalty assessment for a particular violation is an exercise of discretion,
which is bounded by proper consideration for the statutory criteria and the deterrent
purposes of the Mine Act. Id . at 294; Cantera Green , 22 FMSHRC 616,
620 (May 2000).
The maximum penalty
for a violation attributable to an unwarrantable failure is $70,000.00. 30 U.S.C.
§ 820(a)(1). The maximum penalty for a violation properly designated as flagrant
is $220,000.00, adjusted for inflation. 30 U.S.C. § 820(b)(2). The Secretary seeks
to impose a civil penalty of $121,300.00 for the subject accumulations violation
based on the assertion that the violation is attributable to an unwarrantable failure,
and that it is properly designated as a flagrant violation.
Turning to the civil
penalty criteria in section 110(i) of the Act, the evidence reflects that Monongalia
is a large mine operator. Monongalia has stipulated, in essence, that the Secretary’s
proposed penalty in this matter is not disproportionate to the size of its business
and would not impede its ability to remain in business. See stipulation number
5, supra page 4. Monongalia made good faith efforts to address the cited
accumulations after notification of the violation. While Monongalia’s history of
147 section 75.400 violations issued in the two years preceding the issuance of
the subject citation is not exemplary, the violation history must be viewed in the
context of the large size of the Monongalia County Mine that contains approximately
12 miles of beltline.
The deletion of the unwarrantable
failure and flagrant designations with respect to the subject accumulations reflects
a meaningful reduction in the gravity of the violation as well as Monongalia’s degree
of negligence. Nevertheless, although the flagrant and unwarrantable designations
shall be deleted, the degree of Monongalia’s negligence remains high given the duration
and extent of the subject accumulations. Consequently, a civil penalty of $60,000.00
shall be imposed for modification of 104(d)(2) Order No. 8059209 to a 104(a) citation.
IV. Order No. 8059212
Findings of Fact
After observing the
accumulation conditions in the 5 West No. 1 belt entry from the 6 to the 34 block,
Peddicord continued to travel inby to the 40 block. Tr. II 52. At the 41 block Peddicord
traveled through a personnel door where he determined that there was no longer an
obstruction that precluded him from traveling by mantrip to the 13 West headgate
section, the area he initially intended to inspect. Id . Peddicord’s inspection
of the 13 West headgate section did not disclose any violations of mandatory safety
regulations. Id . 52-53.
Upon completion of
his inspection, Peddicord exited the mine and traveled to the mine office where
he issued citations for the violative accumulation conditions he observed in the
5 West No. 1 belt entry. Id . at 53-54. Although Peddicord reviewed the preshift
examination book for the 13 West headgate section prior to entering the mine, upon
returning to the surface, Peddicord reviewed the preshift examination book for the
5 West No. 1 belt entry. Peddicord determined that the preshift examination of the
belt entry conducted during the midnight shift between 5:00 a.m. to 7:16 a.m. for
the oncoming day shift on July 30, 2014, was inadequate. Resp’t Ex. 4.
Consequently, Peddicord
issued Order No. 8059212 for an alleged inadequate preshift examination in violation
of the mandatory safety standard in 30 C.F.R. § 75.360(a)(l) that he attributed
to an unwarrantable failure. Order No. 8059212 states:
The operator
failed to conduct an adequate preshift examination for the 5-
West Company #1 belt
conveyor on the examination conducted on midnight shift for dayshift of 7-30-2014.
A D-2 order #8059209 was issued for accumulations of combustible material being
in numerous locations from 6 block to 34 block on this belt. Citation #8059210 was
issued for damaged rollers being present along this belt conveyor in the same location
as cited accumulations. One of these rollers emitted visible steam when water was
applied. Belt was in operation at time of inspection. Also, Citation #8059211 was
issued for bottom belt contacting 7 consecutive bottom roller cradles at 27 block,
which is also in the same area as the cited accumulations. Accumulations were obvious
and extensive and in contact with many bottom rollers. Accumulations were dark brown
in color and easily visible. The accumulations were over 3400 feet long. The person
conducting this examination failed to report and/or record any of the conditions
discovered during inspection. These conditions were obvious and extensive and should
have been reported and corrected. These areas are required to be preshifted each
shift by a certified mine examiner, because this is an active belt conveyor, and
miners are scheduled to work and travel in these areas. A prudent examination of
these areas would have resulted in the condition being found and reported. Proper
examinations are the first line of defense for the health and safety of the miners.
Foot prints were also observed through the cited accumulations along the cited accumulation
areas. This mine is on a 5- day 103 (I) spot inspection for liberating over 1 million
cubic feet of methane in a 24 hour period. Discovering and reporting hazardous conditions
to mine management is one of the lines of defense for the health and safety of the
miners. If normal mining operations were to continue and inadequate examinations
were to continue it is reasonably likely that miners will suffer injuries from being
exposed to unknown hazardous conditions. This condition is an unwarrantable failure
to comply with a mandatory health and safety standard. This violation is an unwarrantable
failure to comply with a mandatory standard.
Sec’y Ex. 6; Resp’t Ex. 4
Disposition
a.
Unwarrantable Failure
The cited mandatory
safety standard in section 75.360(a)(1), provides, in pertinent part:
(a)(1) [A] certified
person designated by the operator must make a preshift examination within 3 hours
preceding the beginning of any 8-hour interval during which any person is scheduled
to work or travel underground. No person other than certified examiners may enter
or remain in any underground area unless a preshift examination has been competed
for the established 8-hour interval.
30 C.F.R. § 75.360(a)(1).
In determining whether a violation of section 75.360(a)(1)
has occurred, the Commission looks to whether the preshift examination was “adequate”
in identifying hazardous conditions. See, e.g. , RAG Cumberland Resources
LP , 26 FMSHRC 639, 648 (Aug. 2004), aff’d , 171 Fed. Appx. 852 (D.C.
Cir. 2005). Here, it is undisputed that the preshift examination was inadequate
as evidenced by Monongalia’s stipulation to the fact of the violation as well as
the S&S designation. Tr. II 233. However the extent of inadequacy with respect
to an unwarrantable failure is a matter of degree. Although the general factors
of an unwarrantable failure have previously been discussed, the dispositive issue
is whether the cited preshift examination was so perfunctory or otherwise ineffective
that it evidences a degree of negligence that rises to the level of “aggravated
conduct” or “indifference.” Emery Mining Corp. , 9 FMSHRC at
2003.
As a preliminary matter, an element of the preshift violation
cited in Order No. 8059212 is the failure of the belt examiner to note the conditions
cited in Citation No. 8059211 “for bottom belt contacting [six] consecutive bottom
rollers at the 27 block, which is also in the same area as the cited accumulations.”
Sec’y Ex. 6. Specifically, misaligned belt Citation No. 8059211 states, “The 5-West
Company # 1 belt conveyor is not properly aligned to prevent the moving belt conveyor
from contacting belt components in the 27 block[.]” Sec’y Ex. 4. Permitting the
misaligned belt condition at the 27 block to remain uncorrected was attributed to
a low degree of negligence. Id . Yet, the Secretary seeks to rely on Monongalia’s
failure to note this condition in the preshift examination to support his assertion
that the violation is attributable to aggravated conduct. Sec’y Ex. 6; Resp’t Ex.
4.
Viewing Order No. 8059212 in its entirety, the violation
is predicated on the alleged inadequacy of the preshift examination conducted from
5:00 a.m. to 7:16 a.m. on July 30, 2014, rather than on an alleged series of inadequate
preshift examinations. Resp’t Ex. 4. Thus, evaluating the degree of inadequacy of
the subject examination requires consideration of the preshift examiner’s notations
holistically to determine the extent to which relevant hazardous conditions, located
between the 6 and 34 blocks, were noted or overlooked. In this regard, the preshift
examiner made several significant relevant notations concerning the belt entry conditions
in the area inspected by Peddicord. Resp’t Ex. 25. These relevant notations are:
a bad top roller at the 23 block; dark gray accumulations at the 25 block through
the 34 block; and spillage at the 16 block through the 25 block. Id . Thus,
while the subject preshift examination was inadequate, the relevant accumulation-related
conditions noted by the examiner, including accumulations from the 15 block to the
34 block, reflect that the examination was neither perfunctory nor so ineffective
as to render it meaningless.
In addition, the cited preshift examination conducted
from 5:00 a.m. to 7:16 a.m. reflects notations for numerous conditions with regard
to the belt entry conditions in areas that were not inspected by Peddicord. Id .
Specifically, the preshift examiner noted: broken chains at blocks 96, and 97; bad
top rollers at blocks 40, 55, and 63; bad bottom rollers at blocks 41, 47, 63, and
91; and water and spillage at the No. 1 tailpiece and No. 2 tailpiece. Id .
In addition to examining the adequacy of the subject
preshift examination, the adequacy of the preshift examinations preceding the subject
examination is relevant. The numerous notations contained in the preceding preshift
examinations demonstrate that Monongalia was aware of its obligation to conduct
meaningful preshift examinations pursuant to section 75.360(a)(1). Id . For
example, the following notations were recorded: July 27, 2014, preshift
records
contain notations for broken chains at blocks 26, 38, 39, and 40; July 28, 2014,
preshift examination records contain notations for broken chains at blocks 36 through
40 and spillage at blocks 25 through 35; and July 29, 2014, preshift records contain
notations for broken chains at blocks 36 through 40, bad top rollers at blocks 22
and 32, accumulations at blocks 25 through 34, and spillage at blocks 16 through
- Id .
Consequently, the multiple relevant notations in the
preshift examinations immediately preceding the subject examination support the
inference that Monongalia was aware of, and was not indifferent to, its responsibility
to conduct effective preshift examinations. Garden Creek Pocahontas Co .,
11 FMSHRC 2148, 2153 (Nov. 1989) (holding that reasonable inferences may be drawn
if there is a “rational connection between the evidentiary facts and the ultimate
fact to be inferred”).
Significantly, the Secretary has failed to present any
evidence of a relevant history of section 75.360(a)(1) violations that would have
placed Monongalia on notice that greater efforts to perform thorough examinations
were required. Sec’y Ex. 40. On balance, although inadequate, the relevant notations
with regard to accumulation conditions between the 6 block and 34 block, made during
the subject preshift examination, reflect that the inadequacy is attributable to
no more than a moderately high degree of negligence. Accordingly, the Secretary
has failed to demonstrate that the subject preshift examination rises to the level
of aggravated conduct evidencing “reckless disregard,” “intentional misconduct,”
“indifference,” or a “serious lack of reasonable care.” Emery Mining Corp. ,
9 FMSHRC at 2001.
Therefore, 104(d)(2) Order No. 8059212 shall be modified to a 104(a) citation
to reflect that the cited preshift examination violation is not attributable to
an unwarrantable failure.
b.
Civil Penalty
The Secretary seeks
to impose a civil penalty of $40,300.00 for the subject preshift examination violation.
Sec’y Ex. 7. Applying the penalty criteria in section 110(i) of the Act, the evidence
reflects Monongalia is a large mine operator. Monongalia has stipulated, in essence,
that the Secretary’s proposed penalty in this matter is not disproportionate to
the size of its business and would not impede its ability to remain in business.
See stipulation number 5, supra page 4. While the preshift examination
was inadequate with respect to accumulation conditions between the 6 and 34 blocks,
there were numerous notations in the examination book along the entire length of
the 5 West No. 1 belt entry. Resp’t Ex. 25. It is an additional mitigating factor
that the ignition sources that concerned Peddicord, that were overlooked by the
preshift examiner, were attributed to low or moderate negligence. Resp’t Exs. 2,
3; Sec’y Exs. 3, 4. Significantly, the relevant history of violations proffered
by the Secretary reflects that it is a neutral factor in that there were no citations
issued for inadequate preshift examinations in the two years preceding the issuance
of Order No. 8059212. Sec’y Ex. 40; JWR, Inc., 28 FMSHRC 983, 995 (Dec. 2006) (holding
that a general history of violations is sufficient to defeat an operator’s claim
that an absence of a history of similar violations is a mitigating circumstance
with respect to the appropriate civil penalty). Finally, the deletion of the unwarrantable
failure designation reflects a meaningful reduction in Monongalia’s degree of negligence.
Despite the numerous notations
concerning accumulations and conveyor conditions along the entire length of the
5 West No. 1 belt entry, the belt examiner’s failure to adequately note the accumulations-related
conditions between the 6 and 34 blocks during the preshift examination from 5:00
a.m. to 7:16 a.m. on July 30, 2014, evidences a moderately high degree of negligence.
Given the nature and extent of the unrecorded accumulations, a civil penalty
of $22,200.00 shall be imposed for modified 104(a) Citation No. 8059212.
ORDER
IT IS ORDERED that Order No. 8059209
IS MODIFIED to a 104(a) citation to reflect that the unwarrantable failure
and flagrant designations ARE DELETED .
IT IS FURTHER ORDERED that Order No. 8059212
IS MODIFIED to a 104(a) citation to reflect that the unwarrantable failure
designation IS DELETED .
IT IS FURTHER ORDERED that the significant
and substantial designations in 104(a) Citation Nos. 8059209 and 8059212 ARE
AFFIRMED .
IT IS FURTHER ORDERED
that The Monongalia County Coal Company shall pay a civil penalty of $60,000.00
in satisfaction of 104(a) Citation No. 8059209, and a civil penalty of $22,200.00
for 104(a) Citation No. 8059212.
IT IS FURTHER ORDERED
that The Monongalia Coal Company pay, within 40 days of the date of this decision,
a total civil penalty of $82,200.00 in satisfaction of the two citations at issue. [17]
/s/ Jerold
Feldman
Jerold Feldman
Administrative Law
Judge
Distribution:
John A. Nocito, Esq., Suite 630E,
The Curtis Center, 170 S. Independence Mall West, Philadelphia, PA 19106-3306 [email protected]
Helga P. Spencer, Esq., Suite 630E,
The Curtis Center, 170 S. Independence Mall West, Philadelphia, PA 19106-3306 [email protected]
Jason W. Hardin, Esq., 215 South State Street,
Suite 1200, Salt Lake City, UT 84111-2323 [email protected]
Artemis Vamianakis, Esq., 215 South State
Street, Suite 1200, Salt Lake City, UT 84111-2323 [email protected]
[1] Monongalia County
Coal Company does not dispute that it is a proper party based on its role as
successor in interest in Consolidation Coal Company. Resp’t Post-Hr’g Br. at 1-2.
For purposes of this decision, the Respondent shall be referred to as Monongalia,
and the mine site shall be referred to as the Monongalia County Mine. Id
at n.1.
[2] The issuance of
this decision has been delayed due to a medical leave of absence.
[3] Section 75.400 provides:
Coal dust, including float coal dust
deposited on rock-dusted surfaces, and other combustible materials, shall be cleaned
up and not be permitted to accumulate in active workings, or on diesel-powered and
electrical equipment therein.
30 C.F.R. § 75.400.
[4] As a general
matter, a violation is properly designated as S&S if there is a reasonable
likelihood that the hazard against which the mandatory safety standard is
directed will result in an occurrence that is reasonably likely to cause injury
of a reasonably serious nature. Newtown Energy, Inc., 38 FMSHRC 2033,
2037-38 (Aug. 2016).
[5] Section 75.360(a)(1)
states, in pertinent part:
[A] certified person
designated by the operator must make a preshift examination within 3 hours preceding
the beginning of any 8–hour interval during which any person is scheduled to work
or travel underground. No person other than certified examiners may enter or remain
in any underground area unless a preshift examination has been completed for the
established 8–hour interval. The operator must establish 8–hour intervals of time
subject to the required preshift examinations.
30
C.F.R. § 75.360(a)(1).
[6] The transcript
for the three-day hearing consists of three volumes, each volume beginning at
page one. Transcript references shall be cited by volume followed by page number.
At trial, Monongalia moved to replace Consolidation Coal Company as its
successor in interest.
Tr.
I 31-33. The Secretary did not oppose Monongalia’s motion. Id . at 33. Citations
to Consolidation Coal Co . are for pre- trial orders issued prior
to Monongalia’s substitution as the successor in interest.
[7] Stipulations 1-7
are set forth at Tr. I 30-31. Stipulations 8-10 are set forth at Tr. II 120-21,
228-29,
233.
[8] In Order No. 8059212,
issued for the alleged preshift violation, Peddicord noted the misaligned belt contributed
to the bottom belt contacting seven consecutive bottom roller cradles at the 27
block. Sec’y Ex. 6. However, Citation No. 8059211, issued by Peddicord for the misaligned
belt referenced in the subject accumulation citation in Order No. 8059209,
notes that the belt misalignment contributed to belt contact with six bottom roller
cradles. Sec’y Ex. 4. Citation No. 8059211, not a subject of this proceeding,
is discussed infra . At trial, Peddicord also testified that the misaligned
belt caused belt contact with six bottom roller cradles. Tr. I 116. Consequently,
all references to this issue will be to six bottom roller cradles.
[9] A working place
is defined as “Any place in a coal mine where miners are normally required to
work or travel.” 30 C.F.R. § 75.2 (emphasis added).
[10] The issuance of
104(d) withdrawal orders can also result in an interruption of production. In
this case, production was halted from 12:30 p.m. to 8:00 p.m. on July 30, 2014,
to abate the accumulations violation cited in Order No. 8059209. During that period,
approximately 10,000 tons of raw materials resulting in 7000 tons of clean coal
would have been extracted. At a market value of $60.00 per ton, the approximate
eight-hour interruption in mining activities resulted in an approximate loss of
revenue of $420,000.00. Tr. II 178-80.
[11] It is fundamental that:
A statute
is passed as a whole and not in parts or sections and is animated by one general
purpose and intent. Consequently, each part or section should be construed in connection
with every other part or section to produce a harmonious whole. Thus, it is not
proper to confine interpretation to the one section to be construed.
2A Sutherland Statutory Construction § 46:5 at 189-201 (7 th
ed.).
The
Commission did not explicitly include the substantial and proximate cause
requirement for instances where death or serious bodily injury has not yet
occurred in the elements required to establish a flagrant violation. Absent a
Commission directive to the contrary, the proximate cause terminology must be
inferred with respect to accidents that have not yet occurred.
[12] The untraditional
nature of a “broad analysis” is reflected by the Commission’s American Coal
remand instructing the judge “to fashion an interpretation of the flagrant violation
provision . . . which permits the Secretary to establish a violation as flagrant
by taking the operator’s history of previous accumulation violations into account.”
38 FMSHRC at 2082 (emphasis added).
[13] Public documents
published by MSHA are subject to judicial notice. Brody Mining, LLC, 36 FMSHRC
2027, 2030 n.4 (Aug. 2014) (citing Jim Walter Res., Inc. , 7 FMSHRC 1348,
1355 n.7 (Sept. 1985)); Black Diamond Constr., Inc. , 21 FMSHRC 1188, 1189
n.3 (Nov. 1999) (citing Jim Walter Res., Inc. , 7 FMSHRC at 1355 n.7).
[14] The Secretary alleges
that the relied upon predicate violations “were the result of Respondent’s failures
to make reasonable efforts to eliminate known violations of a mandatory health
or safety standard that reasonably could have been expected to cause death or
serious bodily injury.” Sec’y Post-Hr’g Br. at 46-47.
[15] As previously
noted, application of the Secretary’s “repeated” predicate theory in instances
where the discrete violation is not of significant duration, would still
require satisfaction of all other elements identified by the Commission for a flagrant
designation.
[16] It is not
uncommon for Congress, through enabling statutes, to delegate to administrative
agencies the authority to establish policy through either rulemaking or
adjudication. See , e.g. , City of Arlington, Tex. v.
F.C.C. , 668 F.3d 229, 240 (Jan 2012) (holding that the Federal
Communications Commission has the discretion to announce rules through either adjudication
or rulemaking). However Congress, in the Mine Act, delegated to the Commission
the exclusive authority to resolve questions of law and policy through adjudication.
30 U.S.C. § 823(a); see Thunder Basin Coal Co . 510 U.S. 200, n.9 (Jan. 1994);
see also S. Rep. No.
95-181, at 47-48 (1977), as reprinted in 1978 U.S.C.C.A.N. 3401, 3446-47.
Consequently, the Mine Act precludes the Secretary from circumventing the rulemaking
requirements in section 553 of the APA as he lacks the authority to unilaterally
set policy though adjudication.
[17] Payment should
be sent to the Mine Safety and Health Administration, U.S. Department of Labor,
Payment Office, P.O. Box 790390, St. Louis, MO 63179-0390. Please include the
Docket Nos. and A.C. Nos. noted in the above caption on the check.
Find out what applies today
This decision wasn't the final word: the Commission reviewed the case, and its decision is the one that controls. Ezel starts from the controlling decision and answers your specific situation under current law, with citations.
Opens in Ezel Pro. Every answer cites the authority it relies on.