Secretary of Labor (MSHA) v. C F & I Steel Corporation (ALJ decision, September 22, 1981)

C F & I Steel Corporation (FMSHRC WEST 81-134): Trailing cable citation vacated

Decision type
ALJ decision
Docket
WEST 81-134
Decided
September 22, 1981
Presiding judge
Outcome
Citations vacated
Precedential status
Final order, not precedent
Checked against source
2026-10-22
Cited standards

Apply this to your situation

This order from 1981 bound only the parties to this case; it isn't precedent. Ask about your situation and see what the current MSHA standards and Commission precedent say, with citations.

Currency note: this decision dates from 1981
The MSHA standards may have been amended, penalty amounts have been adjusted, and later Commission or court decisions may have changed the analysis since then. Treat this page as historical context, not current compliance advice. Verify the current standard before relying on any specific rule, threshold, or penalty mentioned here.
Final ALJ decision under the Mine Act's 40-day rule
This administrative law judge decision became a final decision of the Commission because no Commissioner directed review within 40 days, under 30 U.S.C. § 823(d)(1). It binds the parties but is not Commission precedent. The full text below is from the official FMSHRC release.
About this page: The plain-English summary and decision snapshot below were written by Ezel based on the official FMSHRC release. The full text is the agency's own release.
Read the official release (fmshrc.gov)

Plain-English summary

MSHA alleged that a battery utility trailer ran over an electrical cable supplying a continuous miner at C F & I Steel Corporation's Allen Mine. Judge John A. Carlson found the dust marks on the cable too uncertain to prove that the heavy vehicle crossed it, especially because the cable was undamaged and only partly pressed into the soft mine floor. He vacated Citation No. 1014211 and dismissed the related penalty petition. The Secretary also withdrew Citation No. 1014217 for lack of sufficient evidence, and the judge dismissed that part of the case. No penalty was assessed.

Decision snapshot

  • Cited standard: 30 C.F.R. § 75.606, protection of trailing cables from mobile equipment.
  • Outcome: Citation No. 1014211 vacated for lack of proof; Citation No. 1014217 withdrawn and dismissed; no penalty.
  • Key point: Dust marks alone did not establish that a vehicle had crossed the cable.

Full text (FMSHRC public release)

CCASE:
SOL (MSHA) v. C F & I STEEL
DDATE:
19810922
TTEXT:
~2168
Federal Mine Safety and Health Review Commission Office of Administrative Law Judges

SECRETARY OF LABOR,
CIVIL PENALTY PROCEEDING
MINE SAFETY AND HEALTH
ADMINISTRATION (MSHA),
DOCKET NO. WEST 81-134
PETITIONER
v. ASSESSMENT CONTROL NO.
05-00296-03055
C F & I STEEL CORPORATION,
RESPONDENT MINE: Allen Mine

DECISION

Appearances: Katherine Vigil Esq.
Office of the Solicitor
United States Department of Labor
1585 Federal Building
1961 Stout Street
Denver, Colorado 80294,
For the Petitioner

Phillip D. Barber Esq.
Welborn, Dufford, Cook & Brown
1100 United Bank Center
Denver, Colorado 80290,
For the Respondent

Before: John A. Carlson, Judge

This case, heard under provisions of the Federal Mine Safety and Health Act of 1977, 30 U.S.C. 801 et seq [the "Act"], arose out of an inspection of respondent's underground coal mine near Weston, Colorado. The Secretary of Labor seeks a $66.00 civil penalty for an alleged violation of a mandatory safety standard.(FOOTNOTE.1) ~2169
Specifically, the citation alleges that respondent failed to provide adequate protection to a trailing cable furnishing electrical power to a continuous mining machine.(FOOTNOTE.2) The matter was tried in Denver, Colorado on July 23, 1981. The parties agreed to waive briefs and submitted the matter after closing arguments.

DISCUSSION

The Secretary's inspector issued the citation because he believed a piece of mobile equipment, a battery utility trailer (BUT car), had run over the trailing cable furnishing power to a continuous miner. He based this belief upon dust marks he observed on the cable as it lay in a haulage way.

Respondent concedes that the cited standard is violated where an operator permits equipment such as a BUT car to move across a cable. It denies, however, that the evidence shows that the cable was in fact run over.

The issue for decision here is whether the circumstantial evidence presented justifies a conclusion that the markings on the cable were left by the wheels of the car. For the reasons which follow, I hold that it does not.

Based upon the undisputed evidence, I find that the car in question weighs several tons. The 440 volt cable, which lay on the soft, moist floor of the haulage way is 2 1/2 inches in diameter and the top of its cover displayed at least one dust mark. I further find that the cable, beneath the mark, was imbedded in the floor a distance of about 1/3 of its diameter; and that subsequent examination disclosed that the cable was undamaged.

As to further particulars, most of the testimony is in conflict. The Secretary's inspector first spoke of a single mark which he believed was 8 or 10 inches wide but did not measure. He said he saw no others, but then revised his testimony to suggest that he saw "two sets of tire marks, one on each side." (Tr. 19-20).

Respondent's own mine inspector, who was present during the government's inspection, insisted that he was shown but a single mark. He also maintained, contrary to the government's inspector, that the mark was solid with no distinctive tread pattern. In his view, the mark was left by the feet of miners who had simply stepped on the cable on their way to work stations.

Both witnesses, of course, rely wholly upon inferences draw from a few observed facts. The respondent's inferences are more persuasive than those of the government. I must agree with respondent, for example, that ~2170 had the heavy BUT car actually crossed the cable, it would have pressed the cable more deeply into the soft floor. That the cable sustained no damage lends further credence to respondent's theory.

In short, the inspector's inferences are too speculative and fragmentary to serve as the basis for a finding of violation. I therefore conclude that no violation was proved.

ORDER

In accordance with the findings and conclusions embodied in the narrative portion of their decision, it is ORDERED that the Secretary's petition for assessment of penalty in connection with citation number 1014211 is vacated, and this present proceeding is dismissed.

It is further ORDERED, pursuant to the Secretary's withdrawal motion, that the petition filed in connection with citation number 1014217 is likewise vacated and that proceeding is dismissed.

John A. Carlson
Administrative Law Judge
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
~FOOTNOTE_ONE
At the outset of the hearing petitioner moved to withdraw a second citation, number 1014217, which was a part of this docket. The Secretary represented that he lacked sufficient evidence to establish violation. The motion was granted and the petition as to that citation was dismissed. The dismissal is reaffirmed here.

~FOOTNOTE_TWO
The standard involved is 30 CFR 75.606 which provides:
"Trailing cables shall be adequately protected to prevent damage by mobile equipment."