Secretary of Labor v. Newmont USA Limited
Secretary of Labor v. Newmont USA Limited (FMSHRC WEST 2010-652-RM, WEST 2010-1584-M): Barricade violation affirmed, S&S finding vacated
Apply this precedent to your situation
This is citable Commission precedent from 2015, and it may have been appealed since. Ezel checks how it stands today and answers your situation, with citations.
Plain-English summary
Newmont shut off an auxiliary fan and tied off ventilation bags in two headings at its Midas gold mine, leaving ropes and signs stating that a heading inspection was required. The Commission affirmed that the headings were unventilated and that ropes and signs that did not prohibit entry failed to satisfy 30 C.F.R. § 57.8528. It vacated the S&S designation because the record did not show a reasonable likelihood of harmful gas buildup or oxygen deficiency. The Commission remanded the unwarrantable-failure issue for findings on whether Newmont's belief that it complied was objectively reasonable, and it also remanded the $5,000 penalty because settled penalties should not be used as templates for litigated cases.
Decision snapshot
- Cited standard: 30 C.F.R. § 57.8528
- Outcome: The violation was affirmed, the S&S designation was vacated, and unwarrantable failure and penalty were remanded.
- Key point: Unventilated headings must be barricaded and posted against entry, while an operator's claimed good-faith compliance must be objectively reasonable.
Full text (FMSHRC public release)
FEDERAL MINE SAFETY AND
HEALTH REVIEW COMMISSION
1331 PENNSYLVANIA AVENUE, NW, SUITE 520N
WASHINGTON, DC 20004-1710
SECRETARY
OF LABOR, :
MINE
SAFETY AND HEALTH :
ADMINISTRATION
(MSHA) :
:
v.
: Docket Nos. WEST
2010-652-RM
: WEST 2010-1584-M
NEWMONT
USA LIMITED :
BEFORE:
Nakamura, Acting Chairman; Cohen and Althen, Commissioners
DECISION
BY:
Nakamura, Acting Chairman; and Althen, Commissioner
These proceedings arise under the
Federal Mine Safety and Health Act of 1977, 30 U.S.C. § 801 et seq. (2012) ("Mine
Act"). At issue is a single order issued by the Department of Labor's Mine
Safety and Health Administration ("MSHA") pursuant to section 104(d)(2)
of the Mine Act, 30 U.S.C. § 814(d)(2),[1]
to Newmont USA Limited ("Newmont") at its Midas Mine, a gold mine in Nevada.
The order alleges a violation of 30 C.F.R. § 57.8528,
which provides: "Unventilated areas shall be sealed, or barricaded
and posted against entry."
On January 5, 2012, the Judge issued his
decision in this case. 34 FMSHRC 146 (Jan. 2011)
(ALJ). The Judge concluded that a violation occurred and that the violation was
significant and substantial ("S&S").[2]
He further concluded that the violation was not attributable to an
unwarrantable failure to comply with the standard[3]
and reduced the civil penalty from $35,500 to $5,000.
The Secretary and the operator filed
cross-petitions for discretionary review of the Judge's decision, which the
Commission granted. For the reasons that follow, we affirm the Judge's finding
of violation, vacate and reverse his S&S finding, and vacate and remand his
non-unwarrantable failure finding. We also remand his penalty assessment.
I.
Factual and Procedural Background
A. Factual
Background
On January 26, 2010, MSHA inspector Shon Guardipee began his
regular inspection of the Midas Mine at the top of a spiral[4] with Newmont employee
Ivan Castellanos and Jamie Wallake, the Miner Representative. As Guardipee
approached the 5301 heading, which was the access off of the main haulage, he observed
that the sill or auxiliary fan at the 5301 level was off and that the
ventilation bags in the headings were tied off. There were signs hanging by a
rope across the headings stating: "Danger, Heading Inspection Required."
When Guardipee questioned the operator's and miners' representatives
accompanying him, they informed Guardipee that the headings had been inactive
for a week and a half. Guardipee subsequently issued the Order, and designated
the violation as S&S and attributable to an unwarrantable failure to comply.
On January 5, 2012, the Judge affirmed the violation and the
S&S designation. He vacated the unwarrantable failure designation and assessed
a civil penalty of $5,000 rather than the $35,500 proposed by MSHA.
B. The Judge's
Decision
1. Whether a
Violation Occurred
The
Judge concluded the operator violated section 57.8528 by failing to
barricade the headings and failing to adequately post signs against entry. He
found that the headings were "unventilated" under the language of the
standard, because the operator had shut down the auxiliary fan and tied off the
ventilation bags in the headings. Id. at 161.
The
Judge found that the plain language of 30 C.F.R. § 57.2 unambiguously defines "barricade"
to require the "prevent[ion] [of] vehicles, persons or flying materials"
from entering unventilated areas, such as the headings in question. Id. According
to the Judge, this requirement was not met because the operator had merely
strung a rope barrier from rib-to-rib at the entrance to each heading and the
signage merely stated: "Danger, Heading Inspection Required." The
signage did not state that entry into the headings was prohibited or that the
headings were unventilated. Id.
2. Whether the
Violation Was S&S
The
Judge also concluded that the violation was S&S. Id. at 161-62. He
found that the hazards of low oxygen and a build-up of toxic gases were
reasonably likely to occur and that the rope across the entry to a heading with
a warning sign that inspection was needed was an insufficient barricade and
signage to comply with the standard.
Although
the Judge acknowledged that new miners at the Midas Mine are required to take a
four-week training class that included inspection procedures for entering
headings, Tr. 228, he further found that subcontractors do not have to take
this training. Thus, he concluded that subcontractors might unwittingly enter
an unventilated heading notwithstanding the rope and signage that an inspection
was required.
The
Judge also considered the testimony of Kevin Hirsch, Assistant District Manager
for the Western District of MSHA, that mines need to be ventilated to ensure
that oxygen remains at the appropriate levels above 19.5 %. The Judge subsequently
reasoned that, without proper ventilation, oxygen levels may not be continually
adequate. 34 FMSHRC at 151, 162; Tr. 119. Consequently, he concluded that low
oxygen was reasonably likely to occur, assuming continuation of normal mining
operations.
The
Judge further found that a build-up of toxic gases was reasonably likely to
occur. 34 FMSHRC at 161-62. Although the Judge recognized that the mine was
non-gassy and that this may be a mitigating factor for S&S purposes, he
concluded that the operation of the diesel and other equipment in the mine made
it reasonably likely that the build-up of toxic gases would occur. Accordingly,
the Judge found that the barricade procedures did not reduce the reasonable
likelihood of miners suffering exposure to toxic gases or a lack of oxygen. As
a result, the Judge found that the violation was S&S.
3. Whether the
Violation Resulted from an Unwarrantable Failure to Comply
The
Judge concluded that the violation did not result from an unwarrantable failure
to comply with the standard. He referred to a meeting in June 2009 between MSHA
and mine operators, including members of Newmont management, at which the
parties discussed the requirements of section 57.8528. He found, however, that they
only discussed what MSHA would accept as a "barricade," as opposed to
the meaning of "unventilated," which would determine when a "barricade"
must be used in the first place. 34 FMSHRC at 151, 164; Tr. 40-44. While noting
that Newmont was cited six times under the standard after the 2009 meeting, based
upon the testimony of Newmont witnesses, the Judge held that the operator possessed
a good faith belief that its policy of roping off headings due to be worked on
in the near future complied with the standard.
The
Judge further found that, in response to the six citations, Newmont updated its
barricading procedures. Under the revised procedure, Newmont continued the
practice of stringing a rope with a sign cautioning "Danger, Heading
Inspection Required" across headings that were presently in production or development,
or scheduled for production or development within four weeks. The Judge found
that Newmont considered such headings to be active headings. Based upon his
finding that Newmont had a good faith belief that its procedures complied with
MSHA's requirements, the Judge held that the operator's violation of section
57.8528 did not result from an unwarrantable failure to comply with the
standard.
4. The Penalty
The Judge assessed a civil penalty of $5,000 rather than the
$35,500 penalty proposed by the Secretary. In doing so, he relied in part on
the settled penalty amounts for the prior citations to conclude that the
proposed penalty in the instant case was "excessive." Id. at 165.
II.
Disposition
A. The Judge
Properly Concluded that a Violation Occurred.
1. The Secretary's definition
of "unventilated" is reasonable and entitled to deference.
30
C.F.R. §
57.8528 provides: "Unventilated areas shall be sealed, or barricaded and
posted against entry." The Secretary asserted that the face of the heading
was "unventilated" because air did not sweep the face in a manner
that would provide oxygen and clear contaminants. The term
"unventilated" is not defined in the standard. Thus, the standard is
silent with respect to whether a face is "unventilated" if airflow is
insufficient to sweep the face.
When
a standard does not provide a definition for a term, the Commission looks to
the term's ordinary meaning. See, e.g., Jim Walter Res.
Inc., 28 FMSHRC 983, 987 (Dec. 2006). "Unventilated" is the
opposite of "ventilated," and "ventilate" has been defined
as "to expose to air and esp[ecially] to a current of fresh air (as
for purifying, curing, or refreshing)." Webster's Third New Int'l
Dictionary Unabridged 2541 (1986). This indicates that airflow must be
sufficient to "purify" or "refresh" the area that is being ventilated.
This definition supports the Judge's interpretation that air must sweep the
face in order for the area to be ventilated. Although we do not find the
dictionary definition to lead inexorably to a plain meaning for
"unventilated," we arrive at the same outcome as the Judge, for we
must defer to the Secretary's interpretation.
If
a term is ambiguous, the Commission defers to the Secretary's interpretations
of his own regulations as long as they are reasonable. Tilden Mining Co.,
36 FMSHRC 1965, 1967 (Aug. 2014) (Secretary's interpretation is reasonable and
entitled to deference); Wolf Run Mining Co., 32 FMSHRC 1669, 1678-82
(Dec. 2010). In Auer v. Robbins, the Supreme Court found that an
agency's interpretation of its own regulation is entitled to deference unless
it is plainly erroneous or inconsistent with the regulation. 519 U.S. 452, 461
(1997). Here, the Secretary's interpretation clearly is reasonable and is
neither erroneous nor plainly inconsistent with the language and the purpose of
the standard.
In the
context of underground mining, a heading is not "refreshed" unless the
airflow is sufficient to sweep its face, regardless of any primary ventilation
or natural airflow. MSHA has noted that "auxiliary ventilation is often
necessary to supply air to dead-end working places, maintain uncontaminated
environments, and to condition air in faces for temperature and humidity control."
New and Revised Safety and Health Standards for Radiation (Radon Daughter
Exposure); Fire Protection and Control; Ventilation, Loading, Hauling and
Dumping; Travelways and Escapeways; Hoisting; and Sanitary Facilities, 44 Fed.
Reg. 31908, 31912 (June 1, 1979) (adopting section 57.8534, which describes
procedures for the shutdown or failure of auxiliary fans). Further, the
Secretary's interpretation is consistent with the standard's purpose, which is
to protect miners from the dangers posed by headings with inadequate oxygen and
accumulations of noxious
gases. Thus, the
term "unventilated" includes airflow that is insufficient to sweep a
heading's face, and we hold that the term "unventilated" in section
57.8528 includes the failure to provide sufficient airflow to sweep the face.[5]
2.
Substantial
evidence supports the Judge's finding that the airflow in the 1-5301
headings was insufficient to sweep the face when Newmont turned off the
auxiliary fan and tied off the ventilation bags.
Newmont's
witnesses did not dispute Guardipee's conclusion that the airflow in the headings
was insufficient to sweep the face. Tr. 271. On the contrary, Sid Tolbert, the
Mine Supervisor at the Midas Mine, admitted on cross-examination that the
natural flow in the mine was insufficient to sweep the face. He acknowledged
that air would sweep the face only when the auxiliary fan was running and the
ventilation bags were operational. 34 FMSHRC at 162; Tr. 271. As
a result, we find that substantial evidence supports the Judge's finding that the
airflow in the 1-5301 headings was insufficient to sweep the face when the
operator turned off the auxiliary fan and tied off the ventilation bags. Accordingly,
we affirm the Judge's finding of a violation.
B. The Judge Erred
in Concluding that the Violation was S&S.
A
violation is S&S if, based on the particular facts surrounding the violation,
there exists a reasonable likelihood that the hazard contributed to will result
in an injury or illness of a reasonably serious nature. See Cement Div., Nat'l
Gypsum Co., 3 FMSHRC 822, 825 (Apr. 1981). In Mathies Coal Co., the
Commission further explained:
In order to establish
that a violation of a mandatory safety standard is significant and substantial
under National Gypsum, the Secretary of Labor must prove: (1) the
underlying violation of a mandatory standard; (2) a discrete safety hazard –
that is, a measure of danger to safety – contributed to by the violation; (3) a
reasonable likelihood that the hazard contributed to will result in an injury;
and (4) a reasonable likelihood that the injury in question will be of a
reasonably serious nature.
6 FMSHRC 1, 3-4 (Jan.
1984).
There
is not substantial evidence to support a finding that the violation contributed
to a discrete hazard reasonably likely to result in an injury. Guardipee's air
readings in the North Heading showed no evidence of
any build-up of contaminants. Tr. 64; Sec'y Ex. A, at 6. Furthermore, Guardipee
failed to take any readings in the South Heading, and he went no further into
the South Heading than immediately after the point where the ventilation bags
were choked off, which was only about 13 feet into the heading. Tr. 322. Significantly,
the mine is non-gassy.
Furthermore, the operator presented undisputed testimony that
whenever the equipment would be running in the headings, the operator, as a
precautionary measure, would block off the opposite, unventilated heading to
prevent access by miners. Tr. 294. In addition, any air that could become
contaminated from drilling and blasting in the headings would not recirculate
through the mine, but rather vent upwards through the portal exhaust. Tr. 226. The
Secretary did not offer any evidence to the contrary. These factors do not
support a finding of a build-up of toxic gases in the headings creating a
reasonable likelihood of injury to a miner.
Concerning the likelihood of any oxygen deficiency, Guardipee's
air readings in the North Heading showed no evidence of any loss of oxygen,
and, as stated above, he failed to take any readings in the South Heading. Further,
the operator's witnesses testified that the rock strata of the mine would not
allow for any loss of oxygen to occur, a point which the Secretary did not
dispute. Tr. 256, 291. The record evidence of the geology of the mine thus mitigates
the likelihood of any oxygen deficiency. We note that the Secretary failed to
introduce evidence of the likelihood of a hazard from oxygen-deficient air. In
sum, substantial evidence does not support the reasonable likelihood of the
build-up of toxic gases or lack of sufficient oxygen that would be reasonably
likely to result in injury to miners.[6] Accordingly, we reverse and vacate
the Judge's S&S finding.
C. The Judge Erred
in Vacating the Secretary's Unwarrantable Failure Designation.
Unwarrantable
failure is aggravated conduct constituting more than ordinary negligence.
Emery
Mining Corp.,
9 FMSHRC 1997, 2001 (Dec. 1987). Unwarrantable failure is characterized by such
conduct as "reckless disregard," "intentional misconduct," "indifference,"
or a "serious lack of reasonable care." Id. at 2003-04; Rochester
& Pittsburgh Coal Co., 13 FMSHRC 189, 194 (Feb. 1991); see also Buck
Creek, 52 F.3d 133, 136 (7th Cir. 1995) (approving unwarrantable failure
test).
Whether
the conduct is "aggravated" in the context of unwarrantable failure
is determined by looking at all the facts and circumstances of each case,
including (1) the extent of the violative condition, (2) the length of time
that it has existed, (3) whether the violation posed a high risk of danger, (4)
whether the violation was obvious, (5) the operator's knowledge of the
existence of the violation, (6) the operator's efforts in abating the violative
condition, and (7) whether the operator has been placed on notice that greater
efforts are necessary for compliance. See Manalapan Mining Co., 35
FMSHRC 289, 293 (Feb. 2013); IO Coal Co., 31 FMSHRC 1346, 1350-57 (Dec.
2009); Cyprus Emerald Res. Corp., 20 FMSHRC 790, 813 (Aug. 1998), rev'd
on other grounds, 195 F.3d 42 (D.C. Cir. 1999). All of the relevant facts
and circumstances of each case must be examined to determine if an operator's
conduct is aggravated or whether mitigating circumstances exist. Consolidation
Coal Co., 23 FMSHRC 588, 593 (June 2001).
The Judge erred by
failing to determine
whether the operator's belief that it was in compliance was objectively
reasonable. The Judge found that "Hirsch gave 'operators specific guidance
about what the Western District would accept as a barricade,'" but no
guidance regarding when a barricade must be used. 34 FMSHRC at 164. The
Judge therefore concluded that the operator possessed a good faith belief that
its policy of roping off headings that were to be worked in the near future in
non-working areas complied with the standard. His analysis, however, overlooks
the fact that, as a matter of law, an operator's belief that it is in
compliance constitutes a defense to an unwarrantable designation only if the
belief was objectively reasonable. See IO Coal, 31 FMSHRC at 1356-60. The
Judge erred by failing to make a finding as to whether the belief was
"objectively" reasonable and explaining the reasons for such a
finding.
We
remand the case to the Judge to make factual findings on the elements of an
unwarrantable failure and whether the operator had an objectively reasonable
belief that the rope and sign utilized by the operator complied with the
regulation.
D. The Judge's Penalty
Assessment Must be Remanded.
The
Judge assessed a civil penalty of $5,000 rather than the $35,500 penalty
proposed by the Secretary. The penalty assessment must be remanded.
In
reviewing the Judge's assessment, it appears that he improperly relied in part
on penalty amounts from similar citations that had previously been settled in
finding that the proposed amount was "excessive." 34 FMSHRC at 164-65; see
also Tr. 312-13. This constitutes an abuse of discretion, as the amount of
penalties assessed in the context of a settlement should not be used to arrive
at penalties assessed in a very different context—in a decision on the merits
after a hearing.[7]
There is no way a Judge can know the facts in settled cases sufficiently to
consider the penalty in such cases in determining a penalty in a litigated
case. Further, the Judge cannot know other factors that may have played a role
in reaching settlement. Use of settlements as templates for penalty
assessments, therefore, would violate the obligation of the Judge to make an
independent judgment and would be made based on insufficient knowledge of
facts, including the motivations for settlement. In short, the results of
settlements should not be considered in the assessment of penalties.
Accordingly,
in light of the foregoing, we remand the case to the Judge to re-assess the
penalty. In so doing, he should also consider: (1) our deletion of the S&S
designation; and (2) his unwarrantable failure finding made on remand.[8]
III.
Conclusion
For
the reasons stated above, we affirm the Judge's finding of a violation, but reverse
and vacate the Judge's S&S finding. We also reverse and remand the case to
the Judge to make additional factual findings regarding whether the violation
resulted from an unwarrantable failure. Finally, we remand the case so that the
Judge may re-assess the penalty in accordance with this decision.
/s/
Patrick K. Nakamura
Patrick
K. Nakamura, Acting Chairman
/s/
William I. Althen
William
I. Althen, Commissioner
Commissioner
Cohen concurring in part and dissenting in part:
I
dissent because I conclude that the Judge's decision to affirm the order as a
significant and substantial (S&S) violation is supported by substantial
evidence in the record. I concur with my colleagues as to the need to vacate
and remand the Judge's unwarrantable failure findings, but write separately on
that issue because I conclude that Newmont's alleged "good faith"
belief that it was in compliance cannot be found to be objectively reasonable. I
join with the majority on all other issues.
A. Significant and
Substantial
The
Judge determined that the Secretary sustained his burden of proof regarding
each of the four elements of the test outlined in Mathies Coal Co.,
6 FMSHRC 1, 3-4 (Jan. 1984). 34 FMSHRC 146, 161-62 (Jan. 2012) (ALJ). My
colleagues reverse the Judge, finding that his decision is not supported by
substantial evidence in the record. They conclude that the evidence does not "support
a finding that the violation contributed to a discrete hazard reasonably likely
to result in an injury." Slip op. at 6.
In
reviewing a Judge's decision to affirm or reject a S&S designation, the
Commission traditionally examines his findings regarding each of the four Mathies
elements to see if they are supported by substantial evidence. See, e.g.,
Black Beauty Coal Co., 34 FMSHRC 1733, 1741-44, 1748-49 (Aug. 2012). I
conclude that the Judge's findings here regarding each of the four elements of
the Mathies test are supported by substantial evidence. "Substantial
evidence" only requires "such relevant evidence as a reasonable mind
might accept as adequate to support [the Judge's] conclusion." Rochester
& Pittsburgh Coal Co., 11 FMSHRC 2159, 2163 (Nov. 1989) (quoting
Consol. Edison Co. v. NLRB, 305 U.S. 197, 229 (1938)).
1. The underlying
violation of a mandatory standard
I join my
colleagues in finding a violation of the standard. Slip op. at 6.
2. A discrete
safety hazard – that is a measure of danger to safety – contributed to by the
violation
The
Judge found that the violation contributed to the danger that a miner will "access
the area and be overcome by noxious air or a lack of oxygen." 34 FMSHRC at
- I conclude that while the Judge articulated the relevant hazard, his
description of the hazard was over-inclusive. See Black Beauty, 34
FMSHRC at 1741. It is sufficient to describe the relevant hazard as a danger
that a miner will access the area and be exposed to noxious air
or a lack of oxygen.
The
Judge's conclusion that the Secretary sustained his burden of proof with
respect to the second element is supported by substantial evidence in the
record. The rope that hung across the 1-5301 headings was insufficient to
prevent either the intentional or unintentional access of the area by a miner. 34
FMSHRC at 161-62; see also Dep. Tr. 46, 51, 52; Sec'y Ex. A, at 6. The
Judge correctly concluded that the rope would not prevent a miner from
traveling under or stepping over it.
While
Newmont may provide rigorous training to its own employees regarding the
inspection of headings, the Judge noted that Newmont's subcontractors do not
receive the same benefit. As a result, the Judge found that the signs hanging
from the rope which stated, "Danger, Heading Inspection Required"
were not a sufficient warning. The sign failed to state that the area was
unventilated or inactive, and as a result contributed to the danger that a
miner may access the area. 34 FMSHRC at 162-63.
The
hazard in this case includes a miner being exposed to noxious air or lack of
oxygen. I disagree with my colleagues' conclusion that there is no substantial
evidence in the record which supports the existence of this hazard. While the
limited readings the inspector took in the headings neither indicated a lack of
oxygen nor the build-up of gases at the exact time the inspection took place,
this is not dispositive. As the Judge noted, conditions in a mine can change
unexpectedly. 34 FMSHRC at 162. This is particularly true in this instance as the
headings at issue were in a development area of the mine. See Tr. 213,
- During this process, which can range from several weeks to years, the area
is not mined continuously; instead, miners regularly visit the headings to take
samples. Tr. 235, 285, 288-89. Depending on the information obtained from the
samples, mining activities may proceed in these areas. Tr. 235. Significantly,
the development process also includes drilling, blasting, and the use of diesel
equipment which produces carbon dioxide and nitrogen dioxide. Tr. 255. Drilling
and blasting work had occurred in the 1-5301 North heading during the month
prior to the inspection. Tr. 264-65. As the Judge noted, the gases emitted by
diesel and other equipment "can build up over time in unventilated areas."
34 FMSHRC at 162.
The
actions of the inspection party are themselves indicative of the potential that
noxious gases and/or lack of oxygen existed in the unventilated 1-5301
headings. MSHA Inspector Shon Guardipee proceeded about 13 feet into the South
Heading when he saw that the ventilation bag was tied off. He turned around and
realized that Mine Foreman Ivan Castellanos and the other members of the
inspection party had not crossed the rope and followed Guardipee into the heading.
Tr. 322. Castellanos testified that he did not enter the heading, and had
"held my people back," because "there was a hazard present."
Id. He explained that it was against company policy to enter a heading
which was unventilated. Tr. 327.
3. A reasonable
likelihood that the hazard contributed to will result in an injury
The
issue for the third element of the Mathies test is whether the hazard
contributed to by the violation was reasonably likely to result in injury. Musser
Eng'g, Inc., 32 FMSHRC 1257, 1281 (Oct. 2010). The Judge found that
it was reasonably likely that a miner accessing the unventilated areas would be
overcome by noxious air or a lack of oxygen. 34 FMSHRC at 161. I conclude that
the Judge's decision is supported by substantial evidence.
I
decline to join my colleagues in reweighing the testimony to account for the
operator's precautionary measures that are taken during development work in the
mine, or to make factual findings as to how air in the mine would potentially
circulate. See Slip op. at 6. As stated above, the hazard of exposure to
noxious air or inadequate oxygen has already been established under step 2 of
the Mathies test.
I
disagree that the Secretary "failed to introduce evidence of the
likelihood of a hazard from oxygen-deficient air." Slip Op. at 7.[9] The
Secretary's evidence included the identification of a similar situation at the nearby
Barrick Meikle Mine, not long before the violation in this case, where one
miner entered an unventilated area and lost consciousness, a second miner
attempted to save him and either lost consciousness or became disoriented, and
it took a third miner turning on ventilation fans to get the other two to
safety. 34 FMSHRC at 150. It was this incident which triggered the inclusion of
a presentation on the barricading required by 30 C.F.R. § 75.8528 at MSHSA's
meeting with mine operators in Elko, NV in June 2009. Tr. 40-41, 76; 34 FMSHRC
at 151.
4. A reasonable
likelihood that the injury in question will be of a reasonably serious nature
The
Judge concluded that it was reasonably likely that an injury that would occur
would be of a reasonably serious nature. 34 FMSHRC at 161. The inspector
concluded the injury would be expected to be fatal. Sec'y Ex. F. The Judge
noted that Inspector Guardipee provided specific examples of miners losing
consciousness from noxious air in similar situations. 34 FMSHRC at 150. Newmont
does not dispute that losing consciousness due to exposure to noxious air is a
reasonably serious injury.
In
conclusion, I would affirm the Judge's factual findings and conclusions
regarding each of the Mathies elements as they are supported by
substantial evidence in the record.
B. Unwarrantable
Failure
I
agree with my colleagues that the Judge erred in vacating the Secretary's
unwarrantable failure designation and that the case must be remanded for reconsideration
of that issue. The Judge vacated the unwarrantable failure designation because
he found that Newmont was not on notice of the Secretary's interpretation of
the regulations. 34 FMSHRC at 164. Thus, the Judge determined that Newmont
"possessed a good faith belief that its policy of roping off headings that
were to be worked in the near future complied with the regulations." Id.
My
colleagues rightly conclude that the Judge erred by failing to make a finding
on whether Newmont's belief was objectively reasonable. However, I would go
further and find, under the facts in this case, that any belief which Newmont
had that its procedures complied with the regulations was not objectively
reasonable.
The
Judge's determination that Newmont was not on notice is based on his finding
that at the June 2009 meeting in Elko, NV, MSHA Assistant District Manager
Kevin Hirsch gave specific guidance as to what its Western District would
accept as a barricade, but did not set forth policy as to when a barricade must
be used under 30 C.F.R. § 57.8528. However, the Judge's determination does not
take into consideration what occurred between the June 2009 meeting and the
issuance of Order No. 6482848 on January 26, 2010. Sec'y Ex. F.
Between
October 14 and October 22, 2009, MSHA issued six separate citations to Newmont
at the Midas Mine for violations of section 57.8528. Sec'y Exs. Q, W, CC, GG,
JJ, MM. Four of these citations (Sec'y Exs. W, CC, GG, MM) explicitly stated
that the heading in question lacked a barricade, and a fifth citation (Sec'y
Ex. JJ) stated that there was only a partial barricade. Any question in the
minds of Newmont's management from the June meeting as to when a barricade was
needed should have been dispelled by the six citations issued in October.
Moreover,
MSHA Inspector Jack Stull testified, without contradiction, that on October 20,
2009, in the course of his issuing Citation No. 6488537 for lack of a barricade
and a proper sign at the 1-4750 South Heading (Sec'y Ex. W), Midas Mine Health
and Safety Specialist Sandy McFarland became "really mad," swore at
Stull, and "said that they're not going to put a barrier up in all the
headings that are going to be mined soon." Tr. 145-46. The next day Stull
and his supervisor Jim Fitch met with McFarland and other Newmont officials. Tr.
153-54. In a meeting lasting an hour, Fitch explained barricading as required
by 30 C.F.R. § 57.8528. Tr. 155-57; Sec'y Ex. K, at 15-16. Surely, any
reasonable question of what section 57.8528 required was dispelled by the
events of October 20-21.
In
November, following the issuance of the October citations, Newmont changed its
barricading procedures. Tr. 237-38, 295. The new policy created three
categories of headings – "Active Heading" (headings are presently in
production or development or scheduled for production or development within
four weeks), which only require a rope barrier; "Short Term Inactive
Heading" (headings which are scheduled for production nor development
within 4 to 12 weeks, or have been removed from active status due to changes in
ground or ventilation), which require a snow fence barricade or a berm; and
"Long Term Inactive Heading" (headings which are scheduled for
production or development beyond 12 weeks, or where mining activities are
complete), which require a chain link fence. NM Ex. 8.[10] Significantly,
while the barricades for Short Term Inactive and Long Term Inactive Headings
are "intended to restrict access into the area", the rope barrier for
Active Headings is only "intended to impede access." Id. Moreover,
the signage required for Active Headings does not clearly restrict access but
only says "Heading Inspection Required." Id.
The
distinction in the new barricading policy between areas requiring a snow fence,
berm or chain link fence designed to "restrict access," and areas
requiring only a rope barrier designed to "impede access" is keyed to
the length of time until production or development – i.e., more or less than
four weeks. Although Newmont's new barricading policy explicitly references and
quotes section 57.8528, it totally ignores the distinction which triggers the
need for a barricade – whether an area is "unventilated." Despite the
series of section 57.8528 citations and the meeting with MSHA in October,
Newmont's new barricading policy simply does not require a barricade for an
unventilated area if the area is scheduled for production or development within
four weeks.
Moreover,
the 1-5301 headings which are the subject of the January 26, 2010 Order in this
case do not appear to even be within Newmont's new policy allowing rope
barriers for areas scheduled for production or development within four weeks. According
to Midas Mine Supervisor Sid Tolbert, on January 26, 2010, Newmont was still
evaluating whether it would continue developing the 1-5301 North and South
Headings, and had not scheduled either heading for production or development. Tr.
- Hence, in merely putting up a rope barrier, Newmont was ignoring its own
policy that rope barriers were to be used only for those headings actually
scheduled for production or development within four weeks.
Given
the series of six citations for section 57.8528 violations in October,
McFarland's adamant behavior on October 20, the meeting with MSHA the next day,
the promulgation of a new policy which does not recognize that the gravamen of
section 57.8528 is whether or not an area is "unventilated," and
Newmont's ignoring of its own policy in permitting the 1-5301 headings to be
unbarricaded on January 26, 2010, the Judge's finding of "good faith"
is doubtful. Even crediting the Judge's finding, it certainly cannot be said
that Newmont's actions constituted objectively reasonable compliance with
section 57.8528.
Finally,
I note that in the Judge's unwarrantable failure analysis, he did not
explicitly consider and weigh several of the factors enumerated in Commission
decisions such as Manalapan Mining Co., 35 FMSHRC 289, 293 (Feb.
2013) and IO Coal Co., 31 FMSHRC 1346, 1350-57 (Dec. 2009). Such
factors include the duration of the violation, the danger posed by the
violation, and the history of violations of section 57.8528 showing that
Newmont had been placed on notice that greater efforts were necessary for
compliance. In considering the issue of unwarrantable failure on remand, the
Judge should consider these factors.
/s/
Robert F. Cohen, Jr.
Robert
F. Cohen, Jr., Commissioner
[1] Section
104(d)(2) provides:
If a withdrawal
order with respect to any area in a coal or other mine has been issued pursuant
to paragraph (1), a withdrawal order shall promptly be issued by an authorized
representative of the Secretary who finds upon any subsequent inspection the
existence in such mine of violations similar to those that resulted in the
issuance of the withdrawal order under paragraph (1) until such time as an
inspection of such mine discloses no similar violations. Following an
inspection of such mine which discloses no similar violations, the provisions
of paragraph (1) shall again be applicable to that mine.
30
U.S.C. § 814(d)(2).
[2] The S&S
terminology is taken from section 104(d)(1) of the Act, 30 U.S.C. § 814(d)(1),
which distinguishes as more serious any violation that "could
significantly and substantially contribute to the cause and effect of a . . .
mine safety or health hazard." 30 U.S.C. § 814(d)(1).
[3] The
unwarrantable failure terminology is also taken from section 104(d)(1) of the
Act, which establishes more severe sanctions for any violation that is caused
by "an unwarrantable failure of [an] operator to comply with . . .
mandatory health or safety standards." 30 U.S.C.
§
814(d)(1).
[4] The mine's
headings are located off of vertical spirals connecting to main haulage roads. Tr.
23, 215; see also Sec'y Ex. B (cross-sectional map looking west at the Midas
Mine and depicting the main haulage roads and spiral system as well as the
ventilation). Newmont uses both a primary and secondary ventilation system. The
primary ventilation is comprised of main fans and booster fans, as well as two
intakes and four exhaust ducts, which are used to provide general airflow for
the main haulage roads and spirals within the mine. Newmont's secondary
ventilation system provides additional airflow for the specific spirals and
their headings. This is done through sill fans, or auxiliary fans, which pull
air from the main haulage roads into internal raises developed alongside each
spiral. Subsequently, the spiral is fed air from the internal raise, and
ventilation bags then direct the air toward the working faces in each spiral's
heading. See Sec'y Ex. QQ. Each heading within a spiral is located 50
feet above or below the other heading. The air pulled upward into Spiral 1 ''Ts
off" into the 1-5301 North and South Headings.
[5] Newmont argues
that the Secretary's interpretation would reduce the flexibility of operators
to direct air where it is needed—that is, to areas where miners are working and
where equipment is emitting potentially noxious gases. It contends that, under
the Secretary's interpretation, the failure to barricade a heading when turning
off a fan for short periods of time, e.g., two minutes or so, to have a
conversation, talk on a radio, or repair a ventilation bag, would violate the
standard. Such a brief stoppage is not the case before us, and the Secretary
has not asserted the position put forward by the operator. But see Tr.
123-24. We decline to act on the basis of conjecture of events that are not
before us. Moreover, policy decisions to promulgate regulations effectuating
the safety purposes of the Mine Act are the province of the Secretary. The
Commission adjudicates whether a regulation is reasonable and not plainly
inconsistent with the Act. See Sec'y of Labor v. Excel Mining, LLC, 334
F.3d 1 (D.C. Cir. 2003).
[6] The Secretary
argues that Kevin Hirsch, the MSHA Assistant District Manager, stated that
headings need to be ventilated to ensure that oxygen remains at the appropriate
levels above 19.5 %, and to prevent oxygen levels from changing unexpectedly in
the future. Tr. 27. This statement, however, is contradicted by Tolbert's
testimony that even with the auxiliary fans off, there would still be
sufficient air circulation in the mine. Tr. 227, 236, 241. For example, Newmont
checked the air circulation in August 2011 during a power outage. The mine did
not have any problems with air quality or quantity at that time. Tr. 242.
[7] As in Sequoia
Energy, LLC, 36 FMSHRC 832, 835 n.5 (Apr. 2014), we need not reach the
broader question of whether the Judge acted improperly by considering past
penalty amounts assessed against the operator. We find error based on the
narrower issue of the use of past settlements as a point of comparison.
[8] Furthermore, as
with all penalty cases, if the Judge's assessment of the penalties
"substantially diverge[s]" from those originally proposed, the Judge must
"provide a sufficient explanation of the bases underlying the penalties
assessed by the Commission." Sellersburg Stone Co., 5 FMSHRC 287,
293 (Mar. 1983), aff'd, 736 F.2d 1147 (7th Cir. 1984).
[9] It really
should not be necessary for the Secretary to introduce case-specific evidence
that noxious gases or inadequate oxygen can result in injury to miners. The
history of mining is replete with such examples, including the 2010 disasters
at the Sago and Aracoma Mines. As the Commission has noted, "[t]he
dangers of low oxygen are well-known and obvious," and so "[o]xygen
levels less than the required level constitute substantial evidence of a
reasonable likelihood of an injury-producing event occurring." Kellys
Creek Res. Inc., 19 FMSHRC 457, 462 (Mar. 1997).
[10] In the
transcript, the updated barricade procedures are referred to as "Exhibit 4."
Tr. 237-40, 295, 306. However, this document is marked as "Exhibit 8"
in the record.
Get today's answer for your situation
You just read Commission precedent from 2015. Ezel checks whether it still stands, including any court review since, and answers your specific situation, with citations.
Opens in Ezel Pro. Every answer cites the authority it relies on.