FMSHRC ALJ decision Docket VA 2014-198 Decided October 22, 2015 Mixed result Judge Thomas P. McCarthy

Secretary of Labor v. Consol Buchanan Mining Company, LLC

Secretary of Labor v. Consol Buchanan Mining Company, LLC (FMSHRC VA 2014-198): Stockpile jurisdiction and methane-recirculation citations affirmed

Apply this to your situation

This order from 2015 bound only the parties to this case; it isn't precedent. Ezel answers your situation under the current MSHA standards and Commission precedent, with citations.

Currency note: this decision dates from 2015
The MSHA standards may have been amended, penalty amounts have been adjusted, and later Commission or court decisions may have changed the analysis since then. Treat this page as historical context, not current compliance advice. Verify the current standard before relying on any specific rule, threshold, or penalty mentioned here.
Final ALJ decision, not Commission precedent
This decision became final under the 40-day rule in 30 U.S.C. § 823(d)(1) because no later Commission review appears in the official index. It binds the parties but is not Commission precedent. The full text below is from the official FMSHRC release.
About this page: The plain-English summary and decision snapshot below were written by Ezel based on the official FMSHRC release. The full text is the Commission's own document.
Read the official release (fmshrc.gov)

Plain-English summary

Consol Buchanan used a site listed as abandoned to store excess clean coal and challenged MSHA's authority over an upper-gate guard house and a bulldozer kept there. Judge Thomas P. McCarthy held that the stockpile remained a mine because storing and loading coal are part of coal preparation, the guard house supported stockpile security, training, and fuel equipment, and the repaired bulldozer was ready for use and not locked or tagged out. He affirmed non-S&S citations for an unlabeled breaker box and overdue fire-equipment inspections, with penalties of $108 each. At Buchanan Mine No. 1, auxiliary fans allowed return air containing methane and dust to recirculate into intake air serving a working section. The Judge found an S&S methane-ignition hazard reasonably likely to cause a fatal injury to four miners in the highly gassy mine, affirmed moderate negligence, and increased that citation's penalty from $1,203 to $2,678. Including an approved partial settlement, he ordered total penalties of $3,502.

Decision snapshot

  • Cited standards: 30 C.F.R. §§ 75.331(a)(4), 77.904, and 77.1110
  • Outcome: Three litigated citations were affirmed, the ventilation citation was amended to fatal gravity with a higher penalty, two citations were settled, and total penalties of $3,502 were assessed.
  • Key point: An active coal stockpile remains under Mine Act jurisdiction despite an abandoned designation, and redundant methane protections do not defeat S&S when return air is recirculated toward a working face.

Full text (FMSHRC public release)

FEDERAL MINE SAFETY
AND HEALTH REVIEW COMMISSION

OFFICE OF
ADMINISTRATIVE LAW JUDGES

1331 PENNSYLVANIA
AVE., N.W., SUITE 520N

WASHINGTON, DC
20004-1710

TELEPHONE:
202-434-9958 / FAX: 202-434-9949

SECRETARY
OF LABOR

MINE
SAFETY AND HEALTH   

ADMINISTRATION
(MSHA),

Petitioner

v.

CONSOL
BUCHANAN MINING

COMPANY,
LLC,

Respondent

CIVIL
PENALTY PROCEEDING

Docket
No. VA 2014-0198

A.C.
No. 44-04856-344491

Mine:
Buchanan Mine #1

DECISION AND
ORDER

Appearances:               Robert
S. Wilson, Esq., Office of the Solicitor, Department of Labor, Arlington,
Virginia and David A. Steffey, Conference and Litigation Representative, Mine
Safety and Health Administration, District 5, Norton, Virginia for Petitioner

Billy
R. Shelton, Esq., Jones, Walters, Turner & Shelton PLLC, Lexington,
Kentucky for Respondent

Before:                        Judge
McCarthy

I. Statement of
the Case

This case is before me upon a petition
for assessment of a civil penalty under section 105(d) of the Federal Mine
Safety and Health Act of 1977, 30 U.S.C. § 815(d). Docket No. VA 2014-0198
involves five citations, Nos. 8208302, 8208448, 8208450, 8208451, and 8196366. At
the outset of trial, the parties filed a Joint Motion to Approve Partial
Settlement of Citation Nos. 8208302 and 8208448.[1]
Tr. I, 20-23. Citation Nos. 8208450, 8208451, and 8196366 remain in dispute.

The primary issues presented are whether
MSHA had jurisdiction to inspect the guard house and bulldozer respectively cited
in Citation Nos. 8208450 and 8208451, whether the auxiliary fan violation
alleged in Citation No. 8196366, as amended at trial, significantly and
substantially contributed to the cause and effect of a respirable-dust health
hazard and/or methane-ignition safety hazard, and whether that alleged
violation was reasonably likely to result in a fatal injury.

A hearing was held on January 26 and 27,
2015 in Abingdon, Virginia. The parties introduced testimony and documentary
evidence.[2]
Witnesses were sequestered.

For the reasons set forth below, I find
that MSHA properly exercised jurisdiction when inspecting the guard house and
bulldozer cited in Citation Nos. 8208450 and 8208451, respectively. I find that
the penalties proposed by the Secretary of $108 for Citation No. 8208450 and $108
for Citation No. 8208451 are consistent with the statutory criteria in section
110(i) of the Mine Act. 30 U.S.C. 820(i).  

I also find that the auxiliary fan
violation alleged in Citation No. 8196366, as amended at trial to allege a
fatal as opposed to permanently disabling injury, significantly and
substantially contributed to the cause and effect of a methane ignition hazard,
which was reasonably likely to result in a fatal injury in this gassy mine. Accordingly,
I find it unnecessary to decide whether that same violation also significantly
and substantially contributed to the cause and effect of a respirable-dust
health hazard that was reasonably likely to result in a fatal injury. Based
upon my independent assessment of the record evidence, I find that the penalty proposed
by the Secretary of $1203 for Citation No. 8196366 should be increased to $2,678
consistent with the statutory criteria in section 110(i) of the Mine Act and my
finding that the severity of gravity increased from permanently disabling to
fatal. 30 U.S.C. 820(i). Accordingly, I assess a total civil penalty of $2,894
for the three remaining violations found herein.

Based on a careful review of the entire
record, including the parties’ post-hearing briefs and my observation of the
demeanor of the witnesses,[3]
I make the following:

II. Findings of
Fact Concerning Citation Nos. 8208450 and 8208451

A.
       Stipulations

The parties stipulated to the following:

1.      The
Administrative Law Judge and the Federal Mine Safety and Health Review
Commission have jurisdiction to hear and decide these civil penalty proceedings
pursuant to Section 105 of the Federal Mine Safety and Health Act of 1977.

2.      Consol Buchanan
Mining Company, LLC [Consol Buchanan] is the owner and operator of the Buchanan
Mine #1.

3.      Operations of
the Buchanan Mine #1 are subject to the jurisdiction of the Act.

4.      The proposed
penalty amounts that have been assessed for the violations at issue pursuant to
30 U.S.C. § 820(a) will not affect the ability of Consol Buchanan to remain in
business.

5.      Consol Buchanan
does not dispute that the MSHA Inspectors listed in Item 22 of the citations at
issue were acting in their official capacity and as authorized representatives
of the Secretary of Labor when each of the citations involved in this
proceeding were issued.

6.      True copies of
each of the citations that are at issue in this proceeding along with all
continuation forms and modifications, were served on Consol or its agents as
required by the Act.

7.      Each of the
violations involved in this matter were abated in good faith.

8.      Government
Exhibit 1 is an authentic copy of Citation No. 8208450, with all modifications
and abatements, and may be admitted into evidence for the purpose of
establishing its issuance and not for the purpose of establishing the accuracy
of any statements asserted therein.

9.      Government
Exhibit 2 is an authentic copy of Citation No. 8208451, with all modifications
and abatements, and may be admitted into evidence for the purpose of establishing
its issuance and not for the purpose of establishing the accuracy of any
statements asserted therein.

10.  Government
Exhibit 3 is an authentic copy of Citation No. 8196366, with all modifications
and abatements, and may be admitted into evidence for the purpose of
establishing its issuance and not for the purpose of establishing the accuracy
of any statements asserted therein.

11. 
With
respect to Citation No. 8196366, Consol Buchanan does not contest the fact of
violation, but does contest the gravity determinations, whether the violation
was significant and substantial, the level of negligence, and the
appropriateness of the proposed penalty amount.

12. 
For
purposes of Section 110(i) of the Act, the proposed penalty amounts are
appropriate given the operator’s history of violations and the size of the
operator.

P.
Ex. C. See also Tr. 9-10, 15.[4]

B.        Background
Facts Concerning Citation Nos. 8208450 and 8208451

Citation Nos.
8208450 and 8208451 are the first citations ever issued at Consol Buchanan’s
VP-8 stockpile site (VP-8). Tr. 201-02. VP-8 was an abandoned mine that
originally consisted of two separate mines, VP-5 and VP-6. Tr. 453. These mines
were owned and operated by Island Creek Coal Co., a subsidiary of Consol
Energy, Inc., until Consol Buchanan, another subsidiary, purchased them
sometime before 2006 and combined them under the Mine ID of VP-5. Tr. 204-05, 453-54.
The combined property, renamed VP-8, was placed in abandoned status in 2006. Tr.
203-04, 453-55. The VP-8 site purportedly remained abandoned until the time of
the citations at issue. Tr. 438-39, 455-57, R-5.

The record establishes that Consol
Buchanan began using VP-8 to stockpile clean coal about a year or two after purchasing
the site from Island Creek. Tr. 371, 401. When the Buchanan Mine #1 produced
more coal than was needed to ship immediately, clean coal was taken from the
Buchanan Prep Plant to the Permac facility, a site two miles down the road,
which could hold about 120,000-130,000 tons of coal. Tr. 69, 399. Once the
Permac facility was full, excess coal was taken to VP-8, which could hold up to
150,000 tons of coal. Tr. 50-51, 69.

VP-8
is situated on the other side of a hill from the Buchanan Prep plant, less than
two miles away as the crow flies, and a four or five mile drive around the
hill. Tr. 200, 240-41. The site has two access points. A lower gate is located
closest to the coal stockpile and was most often used by coal trucks and other
stockpile equipment. An upper gate primarily serviced vehicles traveling to gas
and oil operations up the hill, although the coal stockpile was also accessible
through this gate. Tr. 65-67, 95-96.

Consol Energy, Consol Buchanan’s parent
corporation, contracted with G4S Security to provide security for all equipment
kept at the site. Tr. 322-23. G4S manned a guard house just inside the upper
gate, about 500-600 feet from the coal stockpile. Tr. 214. The original guard
house was replaced with a newer building sometime between October 2013 and
January 2014. Tr. 260-61, 290-93. MSHA inspector Mark Tuggle was the first to
inspect the new guard house in January 2014. Tr. 257.

Coal trucks from the preparation plant
typically accessed VP-8 by the lower gate, but they would use the upper gate
when the stockpile became too large. Tr. 133-34, 138. Although the G4S security
guards stationed at the upper gate did not stop coal trucks, they stopped all
other vehicles going to the coal stockpile, including equipment operators, mine
foremen, contractors, and state and federal inspectors, who were required to
sign in and out of the property. Tr. 100, 104, 108-09, 297-98, 340-41, R-3. Besides
monitoring traffic at the upper gate, the guards occasionally made rounds at
the stockpile area, and they were required to check the lower gate after hours
to make sure it was locked. Tr. 100-01, 316-17. The guards were responsible for
the security of the stockpile equipment. Tr. 218-19, 323. The guards also
provided annual MSHA hazard training for workers at the site. Tr. 98-99,
103-04, 320-21, 405-06, 434-45. The guard house itself provided power to a
nearby fuel tank used to fuel the stockpile equipment. Tr. 214, 262-64, 296,
431-32.

At least by 2012, MSHA began inspecting
the VP-8 stockpile. MSHA inspector Wes Clevinger added the VP-8 stockpile site
to MSHA’s Information Tracking System (ITS) during an inspection in 2012,
although it may have been in the system before that time. Tr. 129-33, 228, 257,
302-04. Clevinger inspected VP-8 several times beginning in 2006. Tr. 122-23. He
and other MSHA inspectors inspected the site regularly between 2012 and 2014. Tr.
122-23, 176-77, 192-93, 239-40. Clevinger examined the old guard house in 2012.
Inspector Robbie Bowers examined the old guard house on March 19 and September
5, 2013. Inspector Tuggle examined it on October 17, 2013. Tr. 134-37, 206-07,
244, 249, P. Ex. 18, 19. Clevinger and Tuggle also inspected the fuel tank,
whenever it was present. Tr. 157-58, 243-44, 249-52, 262; P. Ex. 19.

Throughout all of these inspections,
VP-8 was treated as an adjunct facility of the Buchanan Mine #1 ID, although it
remained in “abandoned” status. Tr. 453; R. Ex. 5. No representative of Consol
Buchanan ever raised any objection to the inspections, or suggested that action
should be taken to officially attach VP-8 to the Buchanan Mine #1 ID. Tr. 127,
180-81, 358, 471-72. No evidence was presented at hearing to show that any loading
or unloading took place at the VP-8 site between August 2, 2013 and September
of 2014, but at the time Tuggle issued the instant citations in January 2014, coal
was stockpiled at the site. Tr. 391-92, 435-36.

Tuggle wrote Citation Nos. 8208450 and
8208451 during his inspections on January 16 and 17, 2014, respectively. Tr.
261; P. Exs. 1 & 2. Citation No. 8208450 alleges a violation of 30 C.F.R. §
77.904, which states:

Circuit breakers
shall be labeled to show which circuits they control unless identification can
be made readily by location.

The
Citation narrative states:

The circuit
breakers installed in the breaker box of the new guard house at the VP#8
location [are] not labeled to show which circuits they control. The circuits [cannot]
be readily identified without use of a meter or similar device.

P. Ex. 1.

Tuggle testified that all the wiring was
in good shape and the breaker box was covered, but the electricians who wired
the guard house should have known that the circuit breaker was not labeled. Tr.
267, 268-69. Since the power cords leading from the circuit breaker were in the
guard house wall, there was no way to identify where they went. Tr. 265. This
created the possibility that someone performing electrical work would fail to
de-energize the correct circuit and would receive an electrical shock. Tr.
267-68.

Tuggle designated Citation No. 8208450
as non-S&S because he determined that the violation was not reasonably
likely to result in injury or illness. P. Ex. 1. Tuggle designated
gravity as lost work days because most workers wear rubber boots or other
insulation, and were likely to receive only a non-fatal shock. Id.; Tr.

  1. Tuggle designated Respondent’s negligence as moderate. P. Ex. 1. A
    Buchanan Prep Plant electrician abated the violation. Tr. 268-69. MSHA proposed
    a civil penalty of $108.

During
the same inspection, Tuggle issued a separate citation, not at issue here, for
an undated fire extinguisher in the guard house. Tr. 253. Respondent did
not contest that citation, and paid the penalty proposed by the Secretary.[5]
Tr. 252-53.

Also
on January 16, 2014, Tuggle noticed a bulldozer before leaving the VP-8 site. Tr.

  1. Although the bulldozer was not locked and tagged out, Tuggle was unable to
    fully inspect it because there was no operator available to operate it for him.
    Tr. 269-70.

The next day, January 17, 2014, Tuggle
returned to the VP-8 site to inspect equipment remaining on the site, including
the bulldozer. Tr. 269-70. Upon examination of the bulldozer, Tuggle wrote Citation
No. 8208451 alleging a violation of 30 C.F.R. § 1110, which states:

Firefighting
equipment shall be continuously maintained in a usable and operative condition.
Fire extinguishers shall be examined at least once every 6 months and the date
of such examination shall be recorded on a permanent tag attached to the
extinguisher.

The condition or practice section of
Citation No. 8208451 states:

The fire
extinguisher provided on the Caterpillar D8N dozer (S/N 9TC1395) has not been
examined since June 2013 or 7 months. Additionally, the on-board fire
suppression system has not been examined since July 2012 or 18 months ago. Both
tags were checked and have same dates of July 2012. Proper examination of fire
fighting equipment is necessary to ensure fire fighting equipment is being
maintained in a usable condition for use when necessary. The operators normal
cycle for the contract fire suppression company is due in February 2014. This
is a spare dozer and not regularly used. The fire extinguisher and fire
fighting system is charged and could be used if necessary.

P.
Ex. 2.

Tuggle designated the citation
non-S&S because he determined that the violation was unlikely to result in
injury or illness. P. Ex. 2. Tuggle designated the gravity as unlikely to
result in a lost-work-days injury because the fire extinguisher was charged and
could be used, despite the stale inspection date. Tr. 276. Tuggle designated
Respondent’s negligence as moderate. P. Ex. 2. MSHA proposed a civil penalty of
$108. P. Ex. A.

Tuggle testified that normal use of a
bulldozer causes it to heat up, and that substances such as antifreeze oil and
hydraulic fluid may provide fuel for a fire. Tr. 276-77. He further testified
that regular inspections of the fire extinguisher helped to ensure the safety
of equipment operators in the event of a fire. Tr. 277.

The dozer had recently undergone
repairs, and had been returned to the VP-8 site about a week before Tuggle
inspected it. The dozer had not been locked and tagged out. Tr. 269, 271-73,
276, 278-79. After it was returned to the VP-8 site from the repair shop, the
dozer’s blade and hoses had been reattached, and superintendent Paul Danko
instructed equipment operator Mike Bradshaw to run the dozer to try it out. Tr.
62-63, 275, 278-79, 380, 421-22 P. Exs. 21, 22; but see Tr. 433.[6]
However, the Secretary failed to establish that the dozer had actually been operated
after its repair and prior to issuance of the citation. Tr. 59, 349, 424.

On the day the citation was issued, the
dozer was situated near the guard house, facing the stockpile. Tr. 274, 288,
418-19. At that time, there was no work being done on the stockpile, although
there was coal stockpiled there. Tr. 288, 435-36.

III.  Legal
Analysis Concerning Citation Nos. 8208450 and 8208451

A.               
 MSHA
Jurisdiction Was Proper Over the VP-8 Site

Consol Buchanan does not dispute that
the conditions alleged in Citation Nos. 8208450 and 8208451 constituted
violations of the cited standards. Respondent put on no evidence to undermine
the citations at trial, and made no arguments on the issue in its post-hearing
brief. R. Br. 9. I credit inspector Tuggle’s uncontested testimony regarding
the fact and gravity of the violations, and I find that the Secretary has met
its burden of proof on these issues. Specifically, I find that the breaker box
in the guard house was unlabeled and that the fire extinguisher on the dozer
had an expired inspection date. Tr. 267-69, 276. Further, I find that each
citation was non-S&S, and unlikely to result in lost workday/restricted
duty injuries. Tr. Tr. 268, 276, P. Ex. 1&2.

Despite conceding the facts of the
violations, Consol Buchanan argues that MSHA lacked jurisdiction to inspect and
issue citations for the guard house and the bulldozer. R. Br. 9. Specifically,
Respondent argued that while the definition of a “mine” under the Mine Act
should be “very broad,” jurisdiction should not be asserted in a way that is
“contrary to common sense.” R. Br. 9-10 citing Southern Nevada Paving,
2008 WL 4287781, *8 (Aug. 2008). In short, it argues that assertion of
jurisdiction over VP-8 is patently irrational.

MSHA derives its jurisdiction over the
nation’s mines and miners from the Mine Act, which states, in pertinent part:

Each coal or
other mine, the products of which enter commerce, or the operations or products
of which affect commerce, and each operator of such mine, and every miner in
such mine shall be subject to the provisions of this Act.

30 U.S.C. § 803.
The
Mine Act defines the reach of the term “mine” broadly to include:

C) . . . structures,
facilities, equipment, machines, tools, or other property . . . used in, or to
be used in . . . the work of preparing coal. . . .

30 U.S.C. § 802(h)(1).
The
Mine Act also defines what constitutes the “work of preparing coal”:

“work of preparing
the coal” means the breaking, crushing, sizing, cleaning, washing, drying,
mixing, storing, and loading of bituminous coal, lignite, or anthracite,
and such other work of preparing such coal as is usually done by the
operator of the coal mine.

30 U.S.C. § 802(i) (emphasis
added).

The
Secretary cites Commission and Circuit Court precedent for the proposition that
MSHA’s jurisdiction must be broadly interpreted. For instance, the Third
Circuit has emphasized Congressional intent that “‘what is considered to be a
mine and to be regulated under this Act’ was to be given the broadest possible
interpretation and that doubts were to be resolved in favor of inclusion of a
facility within the coverage of the Act.” Marshall v. Stoudt’s Ferry
Preparation Co., 602 F.2d 589, 892 (3d Cir. 1979) (quoting S.Rep.No.181,
95th Cong., 1st Sess. 1, 14, reprinted in 1977 U.S.C.C.A.N. 3401, 3414).
The D.C. Circuit echoed this observation in Donovan v. Carolina Stalite Co.,
734 F.2d 1547, 1553-54 (D.C. Cir. 1984) (“Because the Act was intended to
establish a ‘single mine safety and health law, applicable to all mining
activity,’ its jurisdictional bases were expanded accordingly to reach . . .
‘structures . . . which are used or are to be used in the . . . preparation of
the extracted minerals.’” S.Rep. No. 461, 95th Cong., 1st Sess. 37
(1977); S.Rep. No. 181, 95th Cong., 1st Sess. 14 (1977), U.S. Code
Cong. & Admin. News 1977, 3401, 3414.); see also RNS Services Inc. v.
Secretary of Labor, 115 F.3d 182, 185 (3d Cir. 1997) (“The storage and
loading of coal is a critical step in the processing of minerals extracted from
the earth in preparation for their receipt by an end-user, and the Mine Act was
intended to reach all such activities.”); United Energy Servs., Inc. v. Fed.
Mine Safety & Health Admin., 35 F.3d 971, 975 (4th Cir.
1994) (“[T]he proper focus of our analysis is on the safety of mining
operations and . . . we should construe broadly the Act’s coverage to achieve
this goal.”)(citing S.Rep. No. 181, 95th Cong., 1st Sess. 1, 14, reprinted
in 1977 U.S.C.C.A.N. 3401, 3414.).

The
Commission has also consistently given broad and inclusive interpretation to the
jurisdictional limits of the Act. See Secretary of Labor (MSHA) v. Pyramid
Mining, Inc., 16 FMSHRC 2037, 39 (1994) (“The legislative history of the
Mine Act and the Federal Coal Mine Health and Safety Act of 1969 recognize the
hazards presented by abandoned mining areas and address the health and safety
of non-miners as well as miners.”); Secretary of Labor (MSHA) v. Jim Walter
Resources, 22 FMSHRC 21, 22 (2000) (holding that a common supply shop,
which was not located at any mine site and lacked a Mine ID, was subject to
Mine Act jurisdiction).

The
Secretary argues that the VP-8 coal stockpile fits within this broad
interpretation of Mine Act jurisdiction. I agree. Even the most creative legal
mind would be hard pressed to find that a coal stockpile does not fall within
“lands, . . . structures, facilities, . . . or other property . . . used in”
the “storing, and loading” of coal. 30 U.S.C. § 802(h)(1), (i). The site’s
abandoned status and the confusion over the Mine ID do not suffice to defeat
jurisdiction. Pyramid Mining, 16 FMSHRC at 39; Jim Walter Resources,
22 FMSHRC at 22. Indeed, jurisdiction is even more soundly established here
than in those cases because the VP-8 site has not been abandoned, and the
stockpiling of clean coal plays a more direct, integral and essential part of
the mining process than the role played by a supply shop.

Nevertheless,
even assuming MSHA jurisdiction over the VP-8 site generally, Consol Buchanan
argues that MSHA lacked jurisdiction over the guard house and the bulldozer
cited in Citation Nos. 8208450 and 8208451, respectively. For the reasons set
forth below, I find that MSHA properly exercised jurisdiction to inspect the
guard house and the bulldozer, and that Citation Nos. 8208450 and 8208451 were
properly issued, as written.

1.      Jurisdiction Was
Proper Over the Guard House

With regard to the guard house, Consol
Buchanan argues that jurisdiction over the VP-8 site should be restricted to
“areas where the coal was being stockpiled and the areas associated with the
stockpiling of coal.” R. Br. 9. But Consol Buchanan effectively admitted MSHA’s
jurisdiction over the guard house by paying the penalty on the fire
extinguisher citation issued there by Inspector Tuggle during the same
inspection.[7]
Tr. 252-53. Even apart from this settlement admission, I find that Citation No.
8208450 was properly issued, as written, since the guard house was used in, and
its presence in part resulted from, the work of storing and loading coal at the
VP-8 stockpile, and because the guards working in the guard house provided MSHA
hazard training.

In its brief, Respondent argues that the
guard house was located on a separate and distinct area of the VP-8 site, and
that the guard house and the work of the guards who manned it, were not
“integral” or “necessary” to the work of stockpiling coal. R. Br. 9-10. These
arguments lack merit. The guard house itself and the guards who manned it were
located on the VP-8 site and directly involved in the work done at the
stockpile.

Specifically, the circuit breaker in the
guard house cited by inspector Tuggle was used to provide power to the tank
that fueled stockpile equipment. Tr. 263-64. Similarly, employees and equipment
engaged in loading, unloading, and storing coal occasionally used the upper
gate to access the stockpile, especially when it was full. Independent
contractors, like Cleco, signed in at the guard house and assisted in coal
operations. Tr. 394-95; R. Ex. 3 (1/7/14, 1/8/14, 1/10/14). Also, the G4S
guards stationed at the upper gate had important roles in the stockpiling
process. Specifically, these guards would patrol the stockpile and provided
security for the equipment at the stockpile. Tr. 218-19, 323. They also provided
annual MSHA-required, site-specific hazard training to workers at the site. Tr.

  1. Accordingly, I find that these guards were agents of Respondent, lodged
    with apparent authority to hold themselves out to third parties as responsible
    for MSHA training and security at the site. Tr. 218-19, 321-23; Restatement
    (Second) of Agency §§ 8, 27 (1958); see also Martin Marietta Aggregates, 22 FMSHRC 633,
    637-638 (May 2000) (reading the statutory definition of “agent” under 30 U.S.C.
    §
    802(e) “agent” to
    include someone with responsibilities normally delegated to management
    personnel, with responsibilities that are crucial to the mine’s operations, and
    who exercises managerial responsibilities at the time of the negligent conduct). Therefore,
    I conclude that jurisdiction was proper over the guard house as an integral
    part of the VP-8 stockpile site.

Having determined that the guard house
was an integral and necessary part of the mine stockpile, it is also evident
that miners in the guard house, including electricians, could be exposed to
safety hazards within the purview of the Mine Act. Those hazards would include
electrocution or shock hazards posed by de-energizing an unlabeled circuit
breaker in the guard house. Tr. 263-64, 267-68. See W.J. Bokus
Indus., Inc., 16 FMSHRC 704, 708 (Apr. 1994) (MSHA properly cited equipment
(gas cylinders) in a storage garage shared by a sand and gravel operation and
an asphalt plant because cited equipment was “used or [was] to be used in
mining and … could affect miners in the garage.”); Jim Walters Resources, 22
FMSHRC 21 (Jan. 2000) (central supply shop located between one and six miles
from closest coal extraction site is a mine under section 3(h)(1) because a
mine includes “facilities and “equipment” used or to be used in mining
operations or coal preparation facilities).

Accordingly, I find that Citation No.
8208450 was properly issued, as written, and that the proposed penalty of $108
is appropriate under the criteria set forth in section 110(i) of the Act.

2.      Jurisdiction Was
Proper Over the Bulldozer

With
regard to Citation No. 8208451, Consol Buchanan contends that the cited
bulldozer was not in service at the time of the citation.  I find that that
the bulldozer was available for use and was not locked and tagged out.[8]
Commission case law has consistently held that if equipment in violation of
MSHA regulations “has not been rendered inoperable [and] is located in a normal
work area, fully capable of being operated, that constitutes ‘use.’” Wake
Stone Corp. 36 FMSHRC 825, 828 (2014) (quoting Ideal Basic Indus.,
Cement Div., 3 FMSHRC 843, 845 (1981)) (internal quotations omitted); see
also Alan Lee Good, 23 FMSHRC 995, 997 (2001) (finding that even equipment
not to be used on a particular shift must be maintained in functional condition
if not tagged out of operation); Mountain Parkway Stone, Inc., 12 FMSHRC
960, 963 (1990) (finding that “use of the equipment” existed where truck was
not tagged out and was in turn-key condition). The Commission has found that
allowing equipment to stay “parked in a primary working area could allow
operators easily to use unsafe equipment yet escape citation merely by shutting
it down when an inspector arrives.” Ideal Basic 3 FMSHRC at 845.

In
Wake Stone, the Commission held that vehicles “located in a normal work
area, . . . capable of being used, and [not] locked and tagged out . . . were
in ‘use’ at the time of inspection.” Id. at 4. Here, the dozer was
located on the VP-8 site, where it had previously been used to move coal on the
stockpile.[9]
Tr. 59. In fact, it had been sitting at VP-8 for about a week after its return
from the repair shop. Tr. 271-73, 278-79. Superintendent Danko’s testimony
established that, like the equipment in Mountain Parkway, the dozer was
fully capable of being used. It was “ready to go” after the blade and hoses had
been reattached. Tr. 421-22. Further, inspector Tuggle testified that in order
to use the dozer, someone would only have to “open the door and start it.” Tr.

  1. Finally, irrespective of whether the dozer was not ‘logged back in,’ as
    the operator sought to establish,[10]
    the dozer was not locked and tagged out of service, as Commission precedent in Wake
    Stone requires. Tr. 381-83, 274.

The record establishes that no pre-operational
inspection of the dozer was performed during the week that it sat at VP-8
without being locked and tagged out after it was returned from the repair shop.[11] Tr. 283-84. The
fact that Respondent may have performed a pre-operational check before running
the dozer, however, is no basis for vacating the violation. The Commission
specifically rejected that argument in Wake Stone Co., 36 FMSHRC at
828-29, and reinforced the rule that equipment that is not locked and tagged
out of operation and parked for repairs must be maintained in functional
condition. The Commission reasoned that “requiring that operators
continuously keep machinery in operational condition encourages more vigilance
with regard to instituting and enforcing effective maintenance procedures.” Wake
Stone, 36 FMSHRC at 829.

For all of the above reasons, I find
that the bulldozer was “used in, or [was] to be used in” the work of “storing,
and loading” coal under the Act. Therefore, I find that MSHA had jurisdiction
over the bulldozer at the VP-8 site. I conclude that Citation No. 8208451 was
properly issued, as written, and that the proposed penalty of $108 is
appropriate under the criteria set forth in section 110(i) of the Act.

IV. Findings of
Fact and Legal Conclusions Concerning Citation No. 8196366

A.               
Background
Facts

Consol
Buchanan Mine #1 is a large mine that employs about 600 miners, who work on
three shifts. Tr. 481, 482-83. In 2013 and 2014, the mine had eleven mechanized
mining units (MMUs) and used continuous miners and a longwall in super sections
for production operations. Tr. 482. The mine is on a five-day spot inspection schedule
under section 103(i) of the Mine Act because it emits high methane levels
exceeding one million cubic feet of methane every 24 hours.  Tr. 483; 30 U.S.C.
§ 103(i). The Consol Buchanan Mine #1 liberates between ten and eleven million
cubic feet of methane every 24 hours. Tr. 483. The mine has had face ignitions
while cutting sandstone on some of the older panels. Tr. 601.

On
the morning of January 27, 2014, MSHA health inspector Mark Deel arrived at the
Mine to conduct an E01 inspection for respirable dust at mechanized mining unit
(MMU) 015. Tr. 481, 485-86.  Deel and the 015 MMU crew entered the Mine about
7:30 a.m. Tr. 485-86.  After attending a safety briefing with section foreman
David Remines, Deel began an imminent danger run on 015 MMU at about 8:30 a.m. Tr.
486-88, 585-86. Deel measured between 0% to 0.4% methane throughout the
section. Tr. 498-99, 509.

During his imminent danger run, Deel
traveled down the #2 entry to inspect the #2 and #1 face, and to check the dust
parameters on the continuous miner in the #2 entry. Tr. 508. The #2 entry is an
intake air passage, used to ventilate the face with clean air. Tr. 494. Once
air passes down the #2 entry to the face, it is routed back up the #1 entry,
away from working miners. Tr. 494-95. At this point, it is designated as return
air, since it carries coal dust and methane away from the face. Tr. 496, 563.[12]

At the time of Deel’s inspection, there
were two auxiliary fans in the #1 entry, just outby the last open cross cut.
Tr. 508, 519-20; P. Ex. 26. The dog box, a curtain extending across the #1
entry to adjust return air pressure, was situated just inby between the
auxiliary fans and the last open crosscut. Tr. 495, 526; P. Ex. 26. Ventilation
tubing ran all the way from the #1 face, past the dog box, and up to the fans. Tr.
568-69; P. Ex. 26.

It took Deel approximately 45 minutes to
inspect the #2 and #1 face, after which he traveled back up the #2 entry. Tr.
509, 539.  While doing so, Deel observed a cloud of rock dust in the crosscut between
the #1 and #2 entries. Tr. 489, 540, 546, 548. The Secretary stipulated that
the dust observed was rock dust, not coal dust, but Deel testified and the
Secretary alleges that coal dust would have been generated during continued
normal mining operations and mixed with the rock dust creating a respirable
dust hazard that would contribute to pneumoconiosis, a permanently disabling
disease that eventually causes death. Tr. 541, 619.  Upon inspection, Deel discovered
that positive pressure in the #1 return air passage had allowed the check
curtain in the crosscut to fall slack, opening a gap approximately one foot by
five feet, through which return air was entering the #2 intake passage. Tr. 526.

At approximately 10 a.m., Deel wrote
Citation No. 8196366 for a violation of 30 C.F.R. § 75.331(a)(4), which states:

(a) When
auxiliary fans and tubing are used for face ventilation, each auxiliary fan
shall be­— (4) Located and operated to avoid recirculation of air.

The
Citation’s condition or practice narrative states:

The auxiliary
fans being used to ventilate the faces of 015 MMU are not being located and
operated to avoid recirculation of air. When examined return air was being
allowed to recirculate into the intake air ventilating the 015 MMU through a
check curtain located 1 crosscut outby the last open crosscut. This condition
is allowing methane and rock dust to be emitted into the intake atmosphere.
0.3% ch4 was detected coming through the curtain from the return entry. Four
miners are currently working inby this condition on the 015 MMU. This condition
creates the hazards of a methane ignition and exposure to respirable dust that
would result in permanently disabling injures (sic) or disease. Upon continued
normal mining coal dust would be ventilated from the working faces and allowed
to recirculate into the intake air.

P. Ex. 3.

Deel
designated the citation S&S because he determined that the violation
contributed to a health hazard that was reasonably likely to result in a
permanently disabling injury, and he determined that four workers were
affected, as a result of Respondent’s moderate negligence. Tr. 499, 515, 538,
P. Ex. 3. At trial, the Secretary moved to amend the gravity designation to
reasonably likely to result in a fatal injury and to allege both a health and
safety violation. That motion was granted.[13]
Tr. 25-29. MSHA initially proposed a civil penalty of $1203, prior to the amendment.

At the time of the citation, mining had
not yet begun on the section. The four miners, whom Deel observed working inby
the cited condition, were preparing for the shift and cleaning their equipment.
Tr. 487, 496, 515. These miners included two roofbolt operators, a continuous
miner operator, and a section foreman. Tr. 501.

Deel testified that under continued normal
mining conditions, the recurrent recirculation of return air into the intake
air passage would increase the level of methane and coal dust at the face over
time. Tr. 494-96, 500, 524-25, 541-42. Therefore, without abatement of the cited
condition, the hazards of exposure to respirable dust and methane ignition
would worsen over time. Tr. 499-500, 503-04, 529-30, 538. High
levels of respirable coal dust increase the likelihood that miners will develop
pneumoconiosis or black lung disease. Tr. 503, 541, 565. Float coal dust also
contributes to the likelihood that a methane ignition will result in fatal
injury, since coal dust can propagate an explosion. Tr. 503-04, 567.  

Inspector Deel determined that
Respondent’s negligence was moderate. He testified that “The Mine Act requires
the mine operator to have a high standard of care. They’ve got to be on the
lookout for hazards and to correct those hazards.” Tr. 502.  Deel determined
that the level of dust that was “caked” near the back side of the check curtain
indicated that the condition had existed for some time, and should have been
noted during the pre-shift examination. Tr. 502-03. Deel’s notes indicate that
the condition existed for at least 4 hours and should have been noted on the
previous shift. P. Ex. 25, p. 11.  

On cross examination, Respondent
established that 45 minutes earlier, Deel and the section foreman had walked by
this area and did not see any problem with dust emanating around the curtain. Tr.

  1. Further, Respondent established that any coal dust recirculating would
    have been “peppered with” and mixed with rock dust and fallen to the ground
    prior to exiting through the curtain. Tr. 520-21.

Remines
testified that he met Deel at the crosscut when Deel was taking his methane
reading. Tr. 588. Remines testified that he did not see any dust at the check
curtain in the crosscut where Deel testified that he had observed a cloud of
dust; however Remines did acknowledge the negative pressure situation and the
gap in the check curtain.[14]
Tr. 589, 608-09.   

Remines further testified that after
meeting back up with Deel, he immediately walked to the dog box in Entry #1, observed
that it had been knocked out of place, and readjusted it. Tr. 589-91, 609. As
soon as the dog box was adjusted by Remines, the pressure differential created
by the auxiliary fans was rectified, and the hole in the check curtain closed.
Tr. 526, 589-90.  

Meanwhile, after taking the methane
reading, Deel measured the gap in the curtain. Deel was unable to collect any
other data before Remines adjusted the dog box, after which the curtain closed.
Tr. 528.

Section
foreman James Belcher worked the night-owl shift before Deel arrived on the 015
MMU. Tr. 555-56. Belcher testified that after the end of his shift, between
4:30 a.m. and 6:00 a.m., Belcher performed a pre-shift examination of the section.[15]
Tr. 556, 560; R Ex. 6.  Belcher testified that he inspected the check curtain
and crosscut cited in Citation No. 8196366, as well as the dog box and the
auxiliary fans, but he observed no recirculating dust or other hazards. Tr.
556, 557, 575.

Respondent
presented evidence that the Buchanan Mine #1 engages in certain practices to
mitigate the risks posed by respirable dust and methane ignition. While mining
is ongoing, the #1 entry is constantly rock dusted by dusters attached to the
auxiliary fans. Tr. 520, 521, 559-60, 573. Rock dust eliminates float coal dust
by mixing with it and then dropping out of the air. Tr. 573-73, 593-94. Further,
the air pressure in entry #2 is kept at a high volume to dilute methane. Tr.
518-19, 596-97.

In addition, each continuous miner is
equipped with methane detectors located five feet outby the ripper head. Tr. 511-12,

  1. When the methane monitors detect one percent methane, they give a visual
    warning. Tr. 511, 525. At one and a half percent, the continuous miner shuts
    down. Tr. 511-12. However, it is possible for methane monitors to become clogged
    or lose calibration. Tr. 530-31, 616. Furthermore, even when the methane monitors
    are functioning properly, ignition remains possible because methane at the face
    can rise to ignition levels before detection by the monitors. Tr. 534.

The Buchanan Mine also uses a technique
known as “core holing” to map the type of rock present in the roof in front of
the continuous miner. Tr. 605-07. Core holing indicates when the roof is
sandstone, which tends to spark, as opposed to slate, which does not tend to
spark. Tr. 513, 601-03. The roof was slate at the time of Deel’s inspection. Tr.

  1. Although Remines personally has never experienced any problems with the core
    holing technique, he acknowledged on cross examination that sandstone roof
    tends to come and go, that core holing is not always an accurate predictor of
    when sandstone is present, that float dust suspended in the air is explosive, and
    that trailing cables become damaged during continuous mining. Tr. 604-05, 607-08.

Deel observed potential ignition sources
inby the cited condition, such as trailing cables and continuous miner bits,
but he did not examine the cables for damaged jackets or exposed leads. Further,
Deel conceded that cables that are properly maintained are not ignition sources
and that the cited area had adequate air volume and was properly rock dusted. Tr.
501, 512, 535-36.

B.        Citation
No. 8196366 Was a Significant and Substantial Violation and Would Affect Four
Miners

Consol
Buchanan does not specifically dispute the existence of a violation or the designation
of moderate negligence.[16]
Rather, Respondent focuses its challenges on the S&S designation and the
appropriateness of the proposed penalty. R. Br. 12.

The Mine Act describes an S&S
violation as one “of such nature as could significantly and substantially
contribute to the cause and effect of a coal or other mine safety or health
hazard.” 30 U.S.C. § 814(d)(1). The Commission has held that a violation is
S&S “if, based on the particular facts surrounding the violation, there
exists a reasonable likelihood that the hazard contributed to will result in an
injury or illness of a reasonably serious nature.” Cement Div., Nat’l Gypsum
Co., 3 FMSHRC 822, 825 (Apr. 1981). Consistent with the language of section
104(d)(1), it is the contribution of a violation to the cause and effect of a
hazard that must be significant and substantial. U.S. Steel Mining Co.,
6 FMSHRC at 1575. “The fact that injury [or a condition likely to cause injury]
has been avoided in the past or in connection with a particular violation may
be ‘fortunate, but not determinative.’” U.S. Steel IV, supra, 18
FMSHRC at 867, quoting Ozark-Mahoning Co., 8 FMSHRC 190, 192 (Feb.
1986). See also Elk Run Coal Co., 27 FMSHRC 899, 906-07 (Dec. 2005);
Blue Bayou Sand & Gravel, Inc., 18 FMSHRC 853, 857 (June 1996).

To establish an S&S violation under National
Gypsum, the Secretary must prove the four elements of the Commission’s
subsequent Mathies test: (1) the underlying violation of a mandatory
safety standard; (2) a discrete safety hazard – that is, a measure of danger to
safety – contributed to by the violation; (3) a reasonable likelihood that the
hazard contributed to will result in an injury; and (4) a reasonable likelihood
that the injury in question will be of a reasonably serious nature. See
Mathies Coal Co., 6 FMSHRC 1, 3-4 (Jan. 1984) (footnote omitted); accord
Buck Creek Coal, supra, 52 F.3d 133, 135 (7th Cir. 1995) (recognizing wide
acceptance of Mathies criteria); Austin Power, Inc. v. Sec’y of Labor,
861 F.2d 99, 103 (5th Cir. 1988) (approving use of Mathies criteria). An
S&S determination must be based on the particular facts surrounding the
violation and in the context of continued normal mining operations. Texasgulf,
Inc., 10 FMSHRC 498, 500 (Apr. 1988) (quoting U.S. Steel Mining Co.,
6 FMSHRC 1573, 1574 (July 1984)).

The first Mathies element is
satisfied here.  As noted, Consol Buchanan did not specifically contest the
existence of the violation alleged in Citation No. 8196366 at trial or in its
post-hearing brief. In any event, the record evidence establishes a violation
of 30 C.F.R. § 75.331(a)(4) because auxiliary fans used for face ventilation
were not operated to avoid recirculation of air. Rather, probative record
evidence establishes that during continued normal mining operations, the
auxiliary fans located outby the last open crosscut in the Number 1 return air entry
would allow return air from the working faces to recirculate methane and respirable
coal dust (mixing with rock dust) back through a “damaged” check curtain
located one crosscut outby the last open crosscut into the Number 2 entry intake
air course that ventilated 015 MMU. Tr. 494-96, 500, 503, 541-42; see also P.
Ex. 3. As Deel credibly testified, “… the check curtain in the crosscut between
Number 1 and Number 2 had an opening because the pressure from the auxiliary
fans which were inby in the Number 1 Entry caused a positive pressure in the
Number 1 Entry and just caused the curtain to fall slack and away from the rib.”
Tr. 526. This created an opening in the check curtain allowing methane
and rock dust to be emitted back into the intake atmosphere. Tr. 525-26; P. Ex.

  1. Accordingly, I find that the Secretary has established the fact of the violation
    by a preponderance of the evidence.

With regard to the second Mathies
element, the Secretary need only identify a discrete safety or health hazard
associated with the putative S&S violation. Highland Mining Co., 34
FMSHRC 3434, n. 5 (Dec. 2012). The instant increase in respirable coal dust or
methane recirculating to the face contributed to both a health and a safety
hazard. Based on the evidence presented at hearing, I find that under continued
normal mining conditions and without any presumption of abatement, the
violative condition contributed to the discrete safety hazard of a methane
ignition and to the discrete health hazard of respirable dust exposure. Tr.

  1. Continued normal mining operations would release coal dust and methane
    into return air at the face. Tr. 503-04, 530, 541. Without abatement of the
    positive pressure caused by the auxiliary fans at the “damaged” check curtain,
    respirable dust and methane would have continued to “circle the block” and been
    recirculated to the face, where miners worked. Tr. 500, 524-25, 526,
    530, 541.
    I credit Deel’s testimony that there was a cloud of rock dust near the crosscut
    between the Number 1 and Number 2 entries and that the dust was “caked” near
    the back side of the check curtain. [17]
    Tr. 502-03, 539-40, 546.  Further, float coal dust combined with increased
    methane levels and the presence of potential ignition sources creates the
    safety hazard of a methane ignition and propagation. Tr. 503-04.   

Respondent contends that the violation
did not contribute to any discrete safety or health hazard. R. Br. 13. Specifically,
Respondent argues that its safety measures, including rock dusting, ventilation
practices, methane monitors, and core holing, would have prevented the hazards
from ever materializing. Respondent characterizes these safety measures as part
of continued normal mining operations. R. Br. 13. For the following reasons, I
reject Respondent’s argument.[18]

The Commission has consistently held
that the adoption of redundant safety measures to mitigate or extinguish a hazard
does not change the fact that a hazard may pose a serious risk to miners. Buck
Creek Coal Co. v. FMSHRC, 52 F.3d 133, 136 (7th Cir. 1995); Consolidation
Coal Co., 35 FMSHRC 2326, 2330 (Aug. 2013); Cumberland Coal Resources,
LP., 33 FMSHRC 2357, 2369 (Oct. 2011) (redundant, mandatory safety
protections to not constitute a defense to an S&S determination). Respondent’s
redundant safety measures such as ventilation practices, methane monitors, rock
dusting and core holing do not change the fact that methane ignition and overexposure
to respirable coal dust pose serious risks to miners in this gassy mine. Respondent’s
redundant safety measures aim to mitigate or detect these hazards. They do not
eliminate them. Accordingly, I find that the second Mathies element is
satisfied.

With regard to the third Mathies
element, the Secretary demonstrated that the cited condition or violation
contributed to the hazard of methane ignition which was reasonably likely to
result in an injury. The Commission has held that where the violation
contributes to the hazard of methane explosion or ignition, “the likelihood of
an injury resulting from the hazard depends on whether a ‘confluence of
factors’ exists that could trigger an explosion or ignition.” McCoy Elkhorn
Coal Corp., 36 FMSHRC 1987, 1992 (Aug. 2014)(quoting Texasgulf, Inc., 10 FMSHRC 498,
501 (Apr. 1988)). Such factors may include potential ignition sources, the presence
of methane, the presence of float coal dust or loose coal, and the type of
equipment operating in the area. Paramont Coal Company Virginia LLC,
2015 WL 3526151, at *3 (May 2015); Utah Power & Light Co., Mining Div.,
12 FMSHRC 965, 970-71 (May 1990); Texasgulf, 10 FMSHRC 498, 501-03 (Apr.
1988).

Here, the mine has had face ignitions
while cutting sandstone on some of the older panels. Tr. 601. Although the roof
was slate at the time of Deel’s inspection (Tr. 602), foreman Remines
acknowledged that sandstone roof tends to come and go and that core holing is
not always an accurate predictor of when sandstone is present. Tr. 604-05, 607.
A methane content of 0 to .4 percent was already present at the faces and .3
percent methane was present at the check curtain prior to the start of mining
operations. Tr. 524. Deel credibly testified on cross examination that when the
.4 methane at the face mixed with the .3 methane at the curtain to create .7
methane and then recirculated through intake air and around the block, the
buildup of methane would increase. Tr. 500, 524-25. As noted, under normal
continued mining operations, more methane would be released from the face,
along with coal dust. Given the gassy nature of the mine, a sudden buildup of
methane could reasonably be expected to occur. In fact, Congress has recognized
that methane can accumulate rapidly. S. Rep. No. 91-411 at 59, reprinted in
Legis. Hist. 1969 Act at 185. Deel credibly testified that “… inby the methane
monitor, when you start cutting coal, emitting methane, and it gets above the
end of the or into the explosive range before the methane monitor can pick it
up.” Tr. 534. If methane was continually recirculated during continuous normal
mining operations from return air through the check curtain to intake air because
of the auxiliary fan violation, a rapid methane buildup to a 5 percent explosive
level was even more likely.

Furthermore, Deel observed several
potential ignition sources inby the cited condition, specifically trailing
cables and continuous miner bits. Tr. 501. Respondent argues that there was no
evidence that actual ignition sources were present, such as exposed
leads or pieces of sandstone roof that had fallen to the mine floor. Tr. 535-36,
600-01. However, the Commission has long held that the Secretary need not
establish the presence of an imminent danger or actual ignition source in order
to uphold an S&S designation. Elk Run Coal Co., 27 FMSHRC 899, 906
(Dec. 2005); Cement Division, National Gypsum Co., 3 FMSHRC 822, 828
(Apr. 1981). The presence of potential ignition sources is sufficient under the
confluence of factors test. Cf., Buck Creek Coal, Inc. v. FMSHRC,
52 F.3d 133, 135 -136 (7th Cir. 1995)(affirming judge’s S&S determination at
16 FMSHRC at 542, that a tail roller that was completely covered and turning in
combustible coal fines could easily become an ignition source that could cause
a fire if the roller became heated, despite the apparent absence of evidence that
the tail roller was hot or that any defects in the roller were present); Knox
Creek Coal Corp., 36 FMSHRC 1128, 1133-34 (May 2014)(permissibility
violations led to deteriorating conditions that were reasonably likely to
create an ignition hazard in a gassy mine). Accordingly, considering the
specific facts and circumstances of this case, I conclude that there was a
sufficient confluence of factors to establish that the auxiliary fan violation
contributed to a hazard of a methane ignition that was reasonably likely to
result in an injury. [19]

Concerning the fourth Mathies
factor, I find a reasonable likelihood that any injury resulting from the
reasonable likelihood of a methane explosion would be of a reasonably serious
nature and result in a fatality. As the 2010 Upper Big Branch tragedy reminds
us, during continued normal mining operations, the ignition of methane and any subsequent
propagation can lead to a fire or explosion, potentially crushing workers under
heavy rocks, or burning them to death.  See Pinnacle Mining Co., 36
FMSHRC 1918, 1923 (July 2014); Knox Creek Coal Corp., 36 FMSRHC 1128,
1134, 1137 (May 2014); Black Diamond Coal Mining Co., 7 FMSHRC 1117,
1120 (Aug. 1985) (recognizing that “ignitions and explosions are major causes
of death and injury to miners”).  Therefore, I find that the fourth Mathies
element is satisfied.

For all of the above reasons, I find
that the violation alleged in Citation No. 8196366 significantly and
substantially contributed to the cause and effect of a discrete safety hazard of
methane ignition that was reasonably likely to result in a fatality. Therefore,
I affirm the S&S Citation, as amended at trial.

As noted, Deel observed four miners working
inby the cited condition, preparing for the shift and cleaning their equipment.
Tr. 487, 496, 515. They were the two roofbolt operators, a continuous miner
operator, and a section foreman. Tr. 501. Accordingly, I conclude that Deel
reasonably determined that four miners were affected by the violation.

C.
       The Violation was the Result of Respondent’s Moderate Negligence

Further, I conclude that Deel reasonably
determined that Respondent’s negligence was moderate. As Deel testified, “The
Mine Act requires the mine operator to have a high standard of care.  They’ve
got to be on the lookout for hazards and to correct those hazards.” Tr. 502.  Indeed,
the Mine Act imposes a high standard of care on foremen and supervisors. Midwest
Material Co., 19 FMSHRC 30, 35 (Jan. 1997) (holding that “a foreman … is
held to a high standard of care”)); see also Capitol Cement Corp., 21
FMSHRC 883, 892-93 (Aug. 1999) (“Managers and supervisors in high positions
must set an example for all supervisory and nonsupervisory miners working under
their direction, ” quoting Wilmot Mining Co., 9 FMSHRC 684, 688
(Apr. 1987); S&H Mining, Inc., 17 FMSHRC 1918, 1923 (Nov. 1995)
(heightened standard of care required of section foreman and mine superintendent).

Although the Secretary’s definitions of
terms in Part 100 are not binding on the Commission, they nonetheless provide
guidance. See Wade Sand & Gravel Co., _ FMSHRC , slip op. at 4
(Sept. 16, 2015). Relevant to the discussion here, MSHA defines negligence by
regulation in the civil penalty context as “conduct, either by commission or
omission, which falls below a standard of care established under the Mine Act
to protect miners against the risks of harm.” Negligence is further defined as
“the failure to exercise a high standard of care.” 30 C.F.R. § 100.3.  The
level of negligence is properly designated as moderate when “[t]he operator
knew or should have known of the violative condition or practice, but there are
mitigating circumstances.” 30 C.F.R. § 100.3, Table X. The level of negligence
is properly designated as low when there are considerable mitigating
circumstances surrounding the violation. 30 C.F.R. § 100.3, Table X (emphasis
added).

For the reasons previously stated in my
final Big Ridge decision, I find MSHA’s penalty regulations and the
manner in which the Secretary applies them in proposing a penalty to provide
useful guidance.  See Big Ridge Inc., 36 FMSHRC   , slip op. at
4-6 (July 19, 2014) (ALJ); see also Wade Sand & Gravel, supra, slip
op. at 7, n. 1 (Chairman Jordan and Commissioner Nakamura concurring). Based on
the testimony and briefs, I do not find considerable mitigating circumstances
that would justify reducing the negligence designation from moderate to low.  Respondent
highlights none.  In these circumstances, I find that the Secretary properly
designated the level of negligence as moderate.

In this regard, I have credited Deel’s
testimony that the condition had existed for about four hours. Although section
foreman Belcher testified that there were no hazards between 4:30 and 6:00 a.m.
when he concluded his pre-shift examination, Deel did not issue the citation
until four hours later at 10 a.m. Further, Deel pointed to specific and
compelling evidence that rock dust had accumulated and caked near the back of
the curtain. I find that the condition existed for about four hours
after section foreman Belcher completed his pre-shift at 6 a.m. Accordingly, I
conclude that Respondent should have known of the condition at least prior to
Deel’s discovery, particularly since a section foreman was working inby the
cited condition. The moderate negligence designation was appropriate.

D.               
Civil
Penalty

I independently assess the civil penalty
pursuant to the criteria in section 110(i) of the Mine Act. The Buchanon Mine
is a large underground coal mine that produces over 2,000,000 annual tons of
coal. P. Ex. A. It has a low history of previous violations during the prior
15-month period. P. Ex. A and 28. The parties stipulated that the proposed
penalty amounts that have been assessed for the violations at issue pursuant to
30 U.S.C. § 820(a) will not affect the ability of Consol Buchanan to remain in business. MSHA determined
that Respondent demonstrated good-faith in attempting to achieve rapid
compliance after notification of the violations. P. Ex. A. I have found that
the operator was moderately negligent for each violation found. I have affirmed
the gravity determinations for Citation Nos. 8208450 and 8208451, and increased
the severity of gravity with respect to the severity of injury expected in Citation
No. 8196366 from permanently disabling to fatal. Accordingly, I find that the
penalties proposed by the Secretary of $108 for Citation No. 8208450 and $108
for Citation No. 8208451 are consistent with the statutory criteria in section
110(i) of the Mine Act. 30 U.S.C. 820(i). Based upon my independent assessment
of the record evidence, I find that the penalty proposed by the Secretary of
$1203 for Citation No. 8196366 should be increased to $2,678 consistent with
the statutory criteria in section 110(i) of the Mine Act and my finding that
the severity of gravity increased from permanently disabling to fatal. 30
U.S.C. 820(i). Accordingly, I assess a total civil penalty of $2,894 for the
three violations found herein.

V. ORDER

WHEREFORE, the parties’
Joint Motion for Approval of Partial Settlement made on the record is GRANTED.

For the reasons set forth above, I AFFIRM
Citation Nos. 8208450 and 8208451, as written. I further AFFIRM Citation
No. 8196366, as amended at trial to allege that the auxiliary fan safety
violation under section 75.331(a)(4) was reasonably likely to result in a fatal
injury to four miners working inby as a result of Respondent’s moderate
negligence.

It is ORDERED that the operator
pay a total civil penalty of $3,502 for the violations found herein within 30
days of this decision.

/s/ Thomas P.
McCarthy

Thomas
P. McCarthy

Administrative
Law Judge

Distribution:

Robert
S. Wilson, Esq., U.S. Department of Labor, Office of the Solicitor, 1100 Wilson
Blvd., Arlington, VA 22209 and David A. Steffey, Conference and Litigation
Representative, Mine Safety and Health Administration, Norton District Office, Wise
County Plaza, 2nd Floor

P.O. Box 560, Norton, Virginia 24273

Billy
R. Shelton, Esq., Jones, Walters, Turner & Shelton PLLC, 151 N. Eagle Creek
Dr., Suite 310, Lexington, KY 40509

[1] I have reviewed
the parties’ Joint Motion for Partial Settlement as placed on the record at the
hearing. The parties request that Citation No. 8208448 be modified to reduce
the level of negligence from “moderate” to “low” and that the proposed penalty
of $108 be found appropriate. The parties also request that Citation No.
8208302 be modified to delete the “significant and substantial” designation, reduce
the level of negligence from “moderate” to “low,” and reduce the civil penalty
from $807 to $500. Tr. 20-22. I have considered the representations and
documentation submitted. I conclude that the proffered settlement is
appropriate under the criteria set forth in section 110(i) of the Act.

[2] P. Exs. A-C and
P. Exs. 1-30 were received into evidence. Tr. 15-18, 226, 431. R. Exs. 1-7 were
also received into evidence.

[3] In resolving
conflicts in testimony, I have taken into consideration the demeanor of the
witnesses, their interests in this matter, the inherent probability of their
testimony in light of other events, corroboration or lack of corroboration for
testimony given, experience and credentials, and consistency, or lack thereof,
within the testimony of witnesses and between the testimony of witnesses.

[4]
It should
be noted that the parties agreed to two additional stipulations in this matter.
P. Ex. C. However, those stipulations deal with Citation No. 8208302, which was
included in the Joint Motion for Partial Settlement. Therefore, it is not
necessary to include them here. Further, Respondent’s stipulations regarding
the appropriateness of the civil penalty dealt with the proposed penalties as
they were before subsequent modification of Citation No. 8196366 at hearing, as
will be discussed infra.

[5] This fact is
especially significant, as will be discussed infra, because of
Respondent’s adamant objection to jurisdiction in this case.

[6] Danko denied
that he gave this instruction. Tr. 433. However, Bradshaw’s testimony to the
contrary was corroborated by testimony from Tuggle, as well as by Tuggle’s
notes. Tr. 275; P. Ex. 21. I credit Bradshaw’s clear recollection that Danko
instructed him to run the dozer to try it out, as corroborated by Tuggle’s
notes. Moreover, irrespective of this credibility resolution, I find that the
dozer was capable of being operated, which finding is bolstered by other
evidence in the record. See 10-11, infra.

[7] Furthermore,
Consol Buchanan has been on notice of MSHA’s claim of jurisdiction over the
VP-8 site since at least 2011, when the first inspection occurred.  Tr. 177-78;
P. Ex. 14. As noted above, at no point since then did Respondent object to or
question MSHA’s jurisdiction to inspect VP-8. The testimony of Donald Sparkman,
a previous MSHA field office supervisor and current Consol Buchanan safety
manager, does not help Respondent’s position. Tr. 449, 451-52. Sparkman
testified that he thought that MSHA lacked jurisdiction over the VP-8 site, but
suggested that jurisdiction might be appropriate if a Mine ID were properly and
officially attached to the site. Tr. 463, 471-72. Despite testifying that he was
aware that this process would need to be initiated by the operator, Sparkman
failed to initiate this process when he left MSHA to go to work for Consol
Buchanan. Tr. 470-71, 472; see also 30 C.F.R. §§ 41.10-41.13 (regulations
dealing with operators requirement to provide notifications regarding legal
identity of a mine). If Sparkman thought that MSHA was improperly exercising
jurisdiction after he began working for Consol Buchanan, the fact that
he neither raised any objection nor tried to correct the situation by seeking a
VP-8 Mine ID looks like an effort to preserve a technical jurisdictional
argument in case of litigation. It was Sparkman, after all, who first raised the
jurisdictional issue in this case. Tr. 464-65, 467-68.

[8] The dozer was
available for operation. The blade and hoses had been reattached, it was on the
lot where it had previously been operated, and it had not been locked and
tagged out of service. Tr. 59, 269-70, 274.  Operator Bradshaw, prep plant foreman
Case, and superintendent Danko all considered the dozer to be available for use
once the blade and hoses had been reattached. Tr. 62-63, 275, 421-22.

[9] The dozer was
left near the upper gate, 50-60 feet from the fuel tank that was powered by the
guard shack. Tr. 274.

[10] Foreman Case
testified that he did not think the bulldozer had been put back on the active
inventory log, or “back into service.” Tr. 381. However, he admitted that he
wasn’t “100 percent sure” if this was true. Tr. 383.

[11] Superintendent
Danko did look over the dozer shortly after it was delivered, but only to make
sure that it was delivered back on site and had the blade back on it. Tr. 446; see
also Tr. 418-19.

[12] Foreman James
Belcher pithily summarized the critical distinction between intake air and
return air:

Q:        Okay,
so if I understand you correctly, you cannot use return air to ventilate a
working face?

A:        No,
that is bad air.

Tr.
563.

[13] Deel marked the
citation as a health violation, but not a safety violation. Tr. 485, 541-42; P.
Ex. 3. The Secretary moved to amend the citation to allege a safety violation
as well. That motion was also granted. Tr. 28-30. Deel testified that he should
have marked the citation as both a safety and health violation, but as a health
specialist, he only marked the health violation box out of habit and oversight.
Tr. 485, 541-42. I credit Deel’s reasonable explanation as Respondent did not
undermine this testimony on cross. Tr. 516.

[14]
In
resolving this conflict, I credit Deel’s clear recollection of the rock dust,
as corroborated by his notes, which state “dust was observed coming around
check curtain between 1 and 2 entries … a hole is present between the curtain
and the outby rib measuring 1.5 feet x 5 feet with dust coming through the hole
... [d]ust is present on the back side of the stopping that is ½ built
indicating the condition existed on the previous shift.” See P. Ex. 25.

[15]
While I
acknowledge Belcher’s testimony here, I credit Deel’s testimony that the
condition had existed for about four hours. Although Belcher testified that
there were no hazards between 4:30 and 6:00 a.m, Deel did not issue the
citation until four hours later at 10 a.m. Further, Deel pointed to specific
and compelling evidence that rock dust had accumulated and caked near the back
of the curtain. I find that the condition existed for about four hours
after section foreman Belcher completed his pre-shift at 6 a.m.

[16] Although
Respondent initially contested the negligence determination and number of
people affected in its answer and pre-hearing report, it did not mention these
issues in its opening statement at trial, nor did it make argument on these
issues in its post-hearing brief. Tr. 36-41; R. Br. 12.  In any event, I affirm
the moderate negligence determination and the fact that four miners were
affected by violation, as set forth below.

[17] Whether coal
dust was reasonably likely to have made it through the curtain and actually
been recirculated given its likely mixture with rock dust before that point reaches
the third Mathies factor and not the instant inquiry into whether a discrete
health hazard was created by the violation.

[18] On March 23,
2015, after the close of the hearing, the Secretary filed a Notice of
Supplemental Authority. In that notice, the Secretary provided a copy of Judge
Paez’s decision in Mach Mining, LLC, 37 FMSHRC 614 (Mar. 2015). According
to the Secretary, that case was substantially similar to the instant matter. The
Secretary noted that Judge Paez rejected the operator’s argument in that case that
it took additional remedial safety measures and found that an S&S
designation was appropriate despite low measured levels of methane. Respondent
filed a Response to the Secretary’s Notice of Supplemental Authority. In it,
Respondent argued that Judge Paez’s decision was not binding, that other ALJ
decision had made different findings, and that Judge Paez was dealing with a
violation of a ventilation plan rather than an auxiliary fan violation. As will
be discussed infra, in the instant matter Respondent’s remedial efforts and
the low level of methane were immaterial to the ultimate determination. While
Judge Paez’s decision was well-reasoned and persuasive, my findings here
largely rest on the credible facts presented and the cases cited herein.

[19]
I am
persuaded by the testimony elicited by Respondent that coal dust particles in
the air would mix with heavier rock dust and fall to the ground prior to
recirculation of the air. (Tr. 520-21, 573). However, having determined that
the violation was reasonably likely to contribute to an injury as a result of a
methane ignition, I find it unnecessary to decide whether the auxiliary fan
violation also contributed
to a health hazard of inhalation of respirable dust that was reasonably likely
to result in an injury by contributing to the development of black lung disease.

Get today's answer for your situation

You just read what one judge decided for one employer in 2015, and it binds only those parties. Ezel checks the current MSHA standards and Commission precedent and answers your specific situation, with citations.

Opens in Ezel Pro. Every answer cites the authority it relies on.