Secretary of Labor v. Consol Pennsylvania Coal Company, LLC
Secretary of Labor v. Consol Pennsylvania Coal Company (FMSHRC PENN 2022-0011): Escapeway obstruction citation affirmed
Apply this to your situation
This order from 2023 bound only the parties to this case; it isn't precedent. Ezel answers your situation under the current MSHA standards and Commission precedent, with citations.
Plain-English summary
Six pressurized hoses from a pump car protruded into the secondary escapeway at Consol's Enlow Fork Mine. The judge found that the hoses narrowed and obstructed the path used with the escapeway lifeline and could impede miners, including a disabled miner on a stretcher, during an emergency evacuation. He rejected the argument that the remaining space was adequate and evaluated the route under assumed emergency conditions. The violation was affirmed as significant and substantial with moderate negligence because the condition was visible during repeated examinations and safer routing or bridging options were available. Consol was ordered to pay the proposed $2,844 penalty.
Decision snapshot
- Cited standard: 30 C.F.R. § 75.380(d)(1)
- Outcome: The escapeway citation was affirmed as written, with a $2,844 penalty.
- Key point: An escapeway must permit rapid passage under emergency conditions, including passage of a disabled miner, not merely ordinary daily travel.
Full text (FMSHRC public release)
FEDERAL MINE SAFETY AND HEALTH REVIEW
COMMISSION
Office of Administrative Law Judges
1331 Pennsylvania Avenue, N.W., Suite 520N
Washington, D.C. 20004
| SECRETARY OF LABOR, |
| : CIVIL PENALTY PROCEEDING |
| MINE SAFETY AND HEALTH |
| : |
| ADMINISTRATION (MSHA), |
| : Docket No. PENN 2022-0011 |
| Petitioner, |
| : A.C. No. 36-07416-543019 |
| : |
| v. |
| : |
| : |
| CONSOL PENNSYLVANIA COAL COMPANY LLC, Respondent. |
| : : Mine: Enlow Fork Mine : |
DECISION
Appearances: Sharon H. McKenna, Esq., Office of the Solicitor, U.S. Department of Labor, Philadelphia, Pennsylvania, for Petitioner;
Patrick W. Dennison, Esq., Fisher & Phillips LLP, Pittsburgh, Pennsylvania,
for Respondent.
Before: Judge Paez
[This docket is
before me] upon [the Petition for the
Assessment of Civil Penalty filed by the Secretary of Labor pursuant to section
105 of the Federal Mine Safety and Health Act of 1977 (“Mine Act”),
30 U.S.C. § 815.][1]
[In dispute is a single significant and substantial
(“S&S”)][2]
section 104(a) citation issued to CONSOL Pennsylvania Coal Company, LLC for an
alleged violation of an escapeway standard.
To prevail, the Secretary must
prove any cited violation “by a preponderance of the credible evidence.” In
re: Contests of Respirable Dust Sample Alteration Citations, 17 FMSHRC
1819, 1838 (Nov. 1995) (citing Garden Creek Pocahontas Co., 11 FMSHRC
2148, 2152 (Nov. 1989)), aff’d sub nom., Sec’y of Lab. v. Keystone
Coal Mining Corp., 151 F.3d 1096, 1106–07 (D.C. Cir. 1998). This burden of
proof requires the Secretary to demonstrate that “the existence of a fact is
more probable than its nonexistence.” RAG Cumberland Res. Corp., 22
FMSHRC 1066, 1070 (Sept. 2000) (citations and internal quotation marks
omitted), aff’d, 272 F.3d 590 (D.C. Cir. 2001).
I. STATEMENT OF
THE CASE
Citation No. 9204482 alleges CONSOL
violated section 75.380(d)(1) by failing to maintain an escapeway in safe
condition to assure passage of anyone, including disabled persons. 30 C.F.R.
§ 75.380(d)(1). The Commission has held the phrase “maintained in a safe
condition” to mean an escapeway must allow miners to “expeditiously escape a
dangerous underground environment in an emergency.” Am. Coal Co., 29
FMSHRC 941, 950 (Dec. 2007). Specifically, the Secretary alleges six hoses protruding
from a pump car obstructed the escapeway, thus preventing escaping miners from
effectively and safely using the escapeway in the event of an emergency. The
Secretary proposed a penalty of $2,844.00. CONSOL timely answered the petition
and contests the issuance of the citation.
I held an in-person hearing in Pittsburgh, Pennsylvania. At the hearing, the Secretary presented testimony from MSHA Inspector Allan Jack, and CONSOL presented testimony from its Safety Inspector, Joseph Bartolotto. One of CONSOL’s witnesses, Steven Barr, Longwall Coordinator, was ill on the date of the original hearing and unable to attend. With the agreement of counsel, I held a remote Supplementary Hearing the following week to elicit his testimony. Both parties submitted post-hearing briefs and reply briefs.
II. ISSUES
The Secretary argues Citation No. 9204482 must be upheld as S&S and is the result of at least a moderate degree of negligence. (Tr. 21:10–13; Sec’y Post-hr’g Br. 11–23.) CONSOL contests the fact of the violation, the S&S designation, the negligence determination, and the penalty. (Resp’t Post-hr’g Br. 5–25.) Accordingly, the following issues are before me: (1) whether CONSOL violated the provisions of section 75.380(d)(1) as alleged in Citation No. 9204482; (2) whether the citation was properly designated as S&S; (3) whether CONSOL’s negligence was correctly determined as “moderate”; and (4) whether the assessment of a penalty is appropriate.
For the reasons set forth below, Citation No. 9204482
is AFFIRMED as written.
III. FINDINGS OF
FACT
A. Parties’ Stipulations
At the hearing, the parties, in a joint exhibit, stipulated to the following items, verbatim:
-
The Respondent was an “operator” as defined in § 3(d) of the Federal Mine Safety and Health Act of 1977, as amended (hereinafter “the Mine Act”), 30 U.S.C. § 802(d), at the mine at which the Citation at issue in this proceeding was issued.
-
Enlow Fork Mine is a “mine” as defined in §3(h) of the Mine Act, 30 U.S.C. § 802(h).
-
Operations of the Respondent at the mine at which the Citations were issued are subject to the jurisdiction of the Mine Act.
4.
This Citation [Penalty][3]
proceeding is subject to the jurisdiction of the Federal Mine Safety and Health
Review Commission and its designated Administrative Law Judges pursuant to
Sections 105 and 113 of the Mine Act.
-
Enlow Fork Mine is owned by the Respondent.
-
Payment of the total proposed penalty of $2,844.00 for the one citation in this matter will not affect the Respondent’s ability to continue in business.
-
The individual whose name appears in Block 22 of the Citation in contest, Allan Jack, was acting in an official capacity and as an authorized representative of the Secretary of Labor when the Citation was issued.
-
Citation No. 9204482 contained in Docket No. PENN 2022-0011 was issued and served by a duly authorized representative of the Secretary of Labor upon an agent of Respondent at the date, time, and place stated in the Citation, as required by the Act.
-
Exhibit “A” attached to the Secretary’s Petition in Docket No. PENN 2022-0011 contains an authentic copy of Citation No. 9204482 with all modifications or abatements, if any.
(Jt. Ex. 1.)
**B. Operations at the
Enlow Fork Mine **
CONSOL operates the Enlow Fork Mine in Washington County, Pennsylvania and mines bituminous coal underground using the longwall retreat mining process. (Sec’y Post-Hr’g Br. 6; Tr. 41:15–19, 43:13–15, 112:19–113:5.) Enlow Fork Mine is considered a gassy mine because it liberates high amounts of methane requiring ventilation spot checks every five days. (Tr. 55:2–24; II Tr. 38:21–39:23.) Ignitions have occurred at this mine where an accumulation of coal dust or methane ignited with one such ignition resulting in an explosion knocking out ventilation controls and changing the air flow. (Tr. 56:1–57:25.)
Three different entries provide access underground to the longwall sections of the mine: the primary escapeway, the No. 2 Entry (secondary escapeway), and the belt entry. (Tr. 66:9–20, 220:13–15; II Tr. 9:25–10:4.) On a daily basis, most of the mining crew travel along the No. 2 Entry to reach the working face. (Tr. 132:20–134:7.) The preshift examiner also travels the No. 2 Entry. (Tr. 133:14–22.) The No. 2 Entry is also called the track entry, due to the track which traverses down one side of this entry. (Tr. 66:17–20, 68:8–69:5, 86:10–18.) Looking toward the mine exit, the track traverses the No. 2 Entry mostly along the right side, hereinafter the “track side” (Tr. 95:7–21; II Tr. 40:9–23), so miners can walk along the left side, hereinafter the “rib side.” (Tr. 77:18–20, 95:7–18; II Tr. 40:9–23.) A lifeline hangs on the rib side paralleling the track. (Tr. 67:15–17, 141:18–19.) Railcars, known as “pump cars,” transport supplies along the track to the working face. (Tr. 66:17–20, 68:8–69:5, 86:10–18.) One such pump car supplies “pressurized emulsion” through its six hoses for the operation of the longwall. (Tr. 69:1–23, 86:13–18; II Tr. 11:11–22:18; Ex. R–7.) The pump car remains stationary on the track until the longwall face retreats from the original working face to a new crosscut, at which time the pump car moves with the longwall. (Tr. 109:9–16, 113:1–5, 115:13–15.) Because the timing of the longwall’s retreat depends on the rate of mining, the timing of the pump car’s move also varies based on the rate of mining. (Tr. 109:9–11, 112:19–113:18, 114:1–16, 156:22–24, 217:9–15.) The pump car moves on average once per week. (Tr. 114:4–25.)
In the event of an emergency, CONSOL instructs miners to don their ten-minute Self-Contained Self-Rescuers (“SCSRs”)—oxygen masks that miners carry underground which allow a miner to breathe for up to ten minutes in smoky or low-oxygen conditions. (Tr. 102:16–22, 107:4–8, 125:22–126:4.) Miners also use an escapeway lifeline containing directional cones indicating the mine’s exit merely through touch. (Tr. 130:10–19, 227:16–23, 258:6–10.) CONSOL teaches miners to use the lifeline to guide them to a designated location—usually an emergency cache of longer-use SCSRs and tethers—and then to exit the mine. (Tr. 102:9–13.) The longer-use SCSRs allow miners to breathe in smoky or oxygen-scarce conditions for up to an hour. (Tr. 102:13–22, 125:22–126:4.) CONSOL instructs the miners to use the tethers (ropes) to hook themselves together in an emergency, so if a miner loses the lifeline another miner can quickly guide the miner back. (Tr. 102:1–103:12, 201:21–22, 202:23–203:3, 249:9–13.) As required by MSHA, CONSOL trains miners on specific emergency procedures in yearly smoke room trainings where CONSOL fills a room with smoke to simulate an emergency, and miners navigate obstacle courses. (Tr. 34:1–20, 244:1–252:25; II Tr. 49:23–50:4.)
**C. Conditions at Intersection of Entry No. 2
and Crosscut 15.5 on August 17, 2021 **
Crosscut 15.5 of the No. 2 Entry (secondary
escapeway) is sixteen feet wide and eight feet high. (Tr. 75:21–24, 84:25–85:16,
164:19–21; Ex. P–4.) The pump car measures ten to twelve feet wide, leaving
four to six feet between the pump car and the rib side of the No. 2 Entry. (Tr.
85:4–13, 86:19–21, 135:25–136:2, 164:19–25; Ex. P–4.) On August 17, 2021, six
rubber, high-pressure (Tr. 225:8–12) hoses protruded from the side of the pump
car and extended into the walkway of the escapeway, as represented by the red
lines in Exhibit R–7.[4]
(Tr. 66:18–23, 74:4–20, 87:15–88:2, 220:22–221:2; II Tr. 9:25–10:15; Ex. R–7.) At
the time, the pump car sat across from crosscut 15.5 (Tr. 119:7–17; II Tr. 14:6–15:18)
allowing the hoses to extend across the No. 2 Entry and into Crosscut 15.5 to
link up to the longwall. (Tr. 157:15–20.)
Two of the six hoses sat rigidly on
the mine floor and varied in size but spanned two to four inches in diameter,
roughly the size of a baseball or softball. (Tr. 82:11–18, 164:16–17; II Tr.
45:24–47:1.) These two hoses (the hoses closest to the working face) were lying
across the mine floor (Tr. 74:4–15), while the remaining four hoses protruded from
the pump car extending in the air into the escapeway. (Tr. 73:18–23, 74:4–15;
II Tr. 45:6–23; Ex. P–2-2.) Measuring directly below the lifeline (Tr. 79:9–21),
these four protruding hoses hung at heights of 29”, 28”, 15”, and 12” from the
mine floor, depending on the height from which each protruded from the pump
car, as depicted in Exhibit P–2. (Tr. 73:18–23, 74:4–15, 169:1–24; II
Tr. 45:6–23; Ex. P–2-2.) These protruding hoses extended across the full width
of the No. 2 Entry and into Crosscut 15.5, eventually falling onto the mine
floor approximately eight or ten feet from the pump car. (Tr. 82:14–18,
83:11–84:3, 91:11–23.) Measuring perpendicularly to the direction the hoses protruded,
these four suspended hoses spanned six feet along the walkway of the No. 2
Entry. (Tr. 74:4–6.) This means a miner in the escapeway would need to traverse
over six feet of protruding hoses. (Tr. 74:4–6.) Thus, a miner attempting to
escape in the event of an emergency would first encounter [the two rigid pump hoses lying on the mine floor, then the
four suspended hoses at heights of 15”, 29”, 28”, and 12” from the mine floor,
respectively, over six feet of the escapeway. (Tr. 81:5–82:10.)]
The No. 2 Entry (escapeway) lifeline hung from the roof approximately 66 inches above the mine floor (Tr. 75:15–18; II Tr. 25:17–21, 47:6–10; Ex. R–7) on the rib side directly above the pump car hoses. (Tr. 67:15–17, 74:19–20, 219:17–220:12, 233:12–14; II Tr. 48:7–11.) When tugged away from the rib, the escapeway’s lifeline provided about six to seven inches of slack before getting caught on power cables, preventing it from stretching into Crosscut 15.5 where the pump hoses dipped to the mine floor. (Tr. 71:1–8, 83:13–84:3, 88:21–89:13, 171:1–173:3; II Tr. 23:21–24:11, 48:12–16.)
D. MSHA Inspection, Issuance of Citation No. 9204482,
and Abatement
MSHA Inspector Allan Jack arrived at the Enlow Fork Mine on August 17, 2021, for a regular semiannual roof control inspection. (Tr. 44:8–19, 48:10–25.) According to Inspector Jack, Enlow Fork Mine experienced a reduced rate of mining that day due to roof issues. (Tr. 114:4–7, 194:1–11, 270:1–16.) Joseph Bartolotto, Safety Inspector for CONSOL, escorted Inspector Jack underground to Crosscut 15.5. (Tr. 59:17–61:2, 70:10–15; Exs. P–2, R–1.) Using his cap light (Tr. 84:4–16), Inspector Jack observed hoses protruding from the pump car, crossing the width of the No. 2 Entry (escapeway), and proceeding into Crosscut 15.5, whereby he issued Citation No. 9204482. (Tr. 70:15–23, 74:19–20, 79:9–21, 83:11–19, 93:15–94:13, 100:16–101:19.)
In the narrative portion of Citation
No[. 9204482], Inspector Jack wrote:
The alternate escapeway was not being in a safe condition
to always assure passage of anyone in the G2 longwall
section (MMU-011-0) at 15.5 crosscut in the No.2 entry.
Longwall pump hoses were hindering the escapeway
because they were installed between 29 and 12 inches
off the mine floor where the lifeline was coursed over
the hoses causing a tripping hazard to those who have to
use the escapeway.
Standard 75.380(d)(1) was cited 4 times in two years at
mine 3607416 (4 to the operator, 0 to a contractor).
(Ex. P–1.)
Inspector Jack issued this citation at 10:40
a.m. for failure to maintain the escapeway in a safe condition per section
75.380(d)(1). (Tr. 119:23–120:25, 149:15.) He found
the violation to be S&S, reasonably likely to lead to an injury resulting
in lost workdays or restricted duty, and due to CONSOL’s moderate negligence. (Tr.
105:1–11, 129:17–24, 130:20–25; Ex. R–1.) Inspector Jack determined the hazard
in question could affect three persons because miners are usually tethered
together during an emergency escape, so when one miner trips and falls on a
hose that miner is “going to pull a couple people down . . . behind him because
they’re all connected together.” [(Tr. 101:2–16], 122:21–124:1–15.)
Inspector Jack noted that the lifeline went directly over the six hoses at the
heights documented in the citation. He determined that miners could not avoid the
hoses without letting go of the lifeline because the lifeline contained little
slack and was “bow string tight.” (Tr. 79:13–21, 259:5–20.) Letting go of a
lifeline in smoky conditions or poor visibility could result in a miner
becoming disoriented, wandering down a crosscut, and being unable to find the
lifeline again. (Tr. 108:9–14.)
To abate the violation and allow Inspector Jack to terminate the citation, CONSOL moved the No. 2 Entry lifeline into Crosscut 15.5 where the hoses laid on the mine floor due to their greater distance from the pump car. (Tr. 93:17–22, 135:12–141:22; Ex. P–1.) To achieve this, CONSOL added fifteen feet of slack to the lifeline. (Tr. 141:7–15.) This resulted in the lifeline running along the No. 2 Entry (escapeway) rib, extending about eight feet into the opening of Crosscut 15.5 where all six hoses laid on the mine floor, providing miners easier passage, and then continuing along the rib side of the No. 2 Entry on the opposite corner of Crosscut 15.5. (Tr. 177:15–24.) After moving the lifeline, CONSOL placed rock dust bags in front of and between the hoses to create a small bridge over them. (Tr. 93:17–22, 135:12–141:22; Ex. P–1.) This approximately two-foot-wide (II Tr. 29:18–24) “rock dust bag” bridge sat in Crosscut 15.5, approximately eight to ten feet from where the hoses exited the pump car. (Tr. 83:17–84:3, 142:18–20; II Tr. 86:9–87:18.) This “rock dust bag” bridge stood approximately a foot high at its highest point. (Tr. 139:23–140:4.)
IV. ADDITIONAL
FINDINGS OF FACT, PRINCIPLES OF LAW,
ANALYSIS, AND CONCLUSIONS
OF LAW
A. 30
C.F.R. §
Per section 75.380(d)(1) the
following is required of escapeways
in bituminous and lignite mines: “Each escapeway shall be [m]aintained
in a safe [condition to always assure passage of anyone],
including disabled persons.” [30 C.F.R. §][75.380(d)(1)]. [The Commission defines
“maintained in a safe condition,” to mean escapeways that allow miners to “expeditiously
escape a dangerous underground environment in an emergency.” Am. Coal Co.,
29 FMSHRC 941, 950 (Dec. 2007)](“[T]he test with respect to the use of an
escape route is not whether miners have been safely traversing the route under
normal conditions, but rather the effect of the condition of the route on
miners’ ability to
[The Secretary alleges that CONSOL violated][section][75.380(d)(1)], because
miners attempting to use the escapeway in an emergency would need to navigate
over the hoses protruding across the No. 2 Entry. Escaping miners would first
encounter the two rigid hoses lying on the mine floor and then attempt to
hurdle the 15”-high hose, followed by the 29”-high hose, the 28”-high hose, and
finally the 12”-high hose over the course of six feet. (Tr. 81:5–82:10.) In
emergency conditions,[5]
Inspector Jack determined the “first miner in the [line] would hit these hoses,
would trip, would pull two or three miners behind him over as he falls.” (Tr.
104:11–24, 107:9–22.) Inspector Jack noted that subsequent miners would also
struggle because once one miner fell, others would stack on top of the first
miner, creating a chain reaction. (Tr. 122:21–123:2, 124:1–15.) When miners
trip, they may sustain injuries from the fall itself, as well as lose valuable
time needed to escape from the mine. (Tr. 108:9–14, 128:19–25.)
CONSOL argues that
no violation of section 75.380(d)(1) occurred. CONSOL points to section
75.380(d)(4)(iii) which mentions a “stretcher test” and asserts that disabled
miners could safely escape because a stretcher could fit through the escapeway
and, thus, no escapeway violation exists. (Resp’t Post-hr’g Br. 10, 11, 23.) Not
only is this argument inapposite but it misinterprets and misapplies the
Commission’s stretcher test rule. The stretcher test under section 75.380(d)(4)
requires that a stretcher with an injured miner be able to fit through the
escapeway. 30 C.F.R. § 75.380(d)(4)(iii). Inspector Jack issued Citation No. 9204482
for hoses obstructing the escapeway, not for an insufficiently wide escapeway—which
the exceptions like the stretcher test under section 75.380(d)(4) are meant to
address. Indeed, the Commission found that sufficient width, while necessary
for a safe escapeway, is insufficient, on its own, to assure the safe escape of
disabled persons. Maple Creek Mining, Inc., 27 FMSHRC 555, 560 (Aug.
2005) (finding the escapeway inadequate where additional miners were required
to guide a stretcher through the escape route by pointing out obstacles along
the way.) While the parties here agree the No. 2 Entry (escapeway) was wide
enough for a stretcher, it did not assure safe passage for a stretcher. (Tr.
167:2–8.) Inspector Jack emphasized that if a team of
miners needed to carry a miner on a stretcher, the team’s unexpected navigation
over the protruding and uneven hoses would create a “mess,” by endangering
those carrying the stretcher and delaying medical attention for the injured
miner. (Tr. 151:10–11.) I am not persuaded by CONSOL’s argument
regarding the stretcher test and reject it as misplaced.
Rather than addressing the safety issue
created by the protruding hoses, CONSOL makes arguments as to why section 75.380(d)(1)
should not apply under the circumstances. (Resp’t Post-hr’g Br. 5–7.) Among
these, CONSOL argues for no violation because: (1) the Secretary cited the
wrong standard; (2) the Secretary added requirements to the regulation; (3) an
exception to the standard applies; and (4) abatement did not improve the
condition. (Id.)
First, CONSOL argues that the
Secretary cited the wrong standard and should instead have cited a lifeline
standard. (Resp’t Post-hr’g Br. 12.) However,
the Commission held that whether an alternate standard could have been cited
for a condition does not negate the applicability of the cited standard. CONSOL
Pa. Coal Co., 44 FMSHRC 691, 696 n.10 (holding “[w]hether or not a different subsection of the standard would
have also been applicable, has no bearing on whether the Secretary established
a violation of [the cited standard]. . . .”). Here, the position of the
lifeline has no bearing on the fact that hoses protruded from the pump car
creating an unsafe condition by hampering passage along the No. 2 Entry
(escapeway) that could injure and/or delay miners from expeditiously escaping a
dangerous underground environment in the event of an emergency.
Second, CONSOL asserts that the
Secretary added requirements to section 75.380(d)(1), arguing Inspector Jack
issued the violation for the lifeline hanging over the pump car hoses, which adds
requirements on the placement of the lifeline. (Resp’t Post-hr’g Br. 8, 12; Resp’t
Reply Br. 5.) Yet again, CONSOL’s argument strains logic because Inspector Jack
did not issue the violation for the presence of the lifeline above the hoses
but rather because the hoses created unsafe conditions for use of the escapeway
in the event of an emergency.[6]
(Ex. P–1.)
Third, CONSOL argues that no
violation existed because the pump car hoses were “essential to the ongoing operation of [the] longwall section”
and, therefore, the exception under section 75.380(d)(4)(iv)[7]
applies. (Tr. 153:5–156:11; II Tr. 65:21–25; Resp’t Post-hr’g Br. 10, 11; Resp’t
Reply Br. 2–4.) However, CONSOL mischaracterizes section 75.380(d)(4)(iv) in
that a plain reading reveals that such “essential” equipment only provides an
exception to the requirement that an escapeway be maintained to a width of six
feet (which is not an issue in this case). 30 C.F.R. § [75.380(d)(4)(iv)].
Section 75.380(d)(4)(iv) is not an exception to the requirement that the
escapeway be maintained in a “safe condition,” as required by section 75.380(d)(1).
Thus, the “essential” nature of the hoses to the longwall operation does not
excuse CONSOL from ensuring the pump car hoses are situated in a manner so the
escapeway is maintained in a safe condition to assure passage expeditiously in
the event of an emergency. See 30 C.F.R. § 75.380(d)(1). Consequently,
the pump car hoses can remain in the escapeway so long as they are situated
in a “safe condition,” which was not the case here as described above. (Tr.
153:5–9, 164:2–7.)
Finally, CONSOL contends no
violation existed because abatement did not improve the hazard, as the rock
dust bags themselves could trip miners or cause miners to hit their heads. (Resp’t
Post-hr’g Br. 15–17, 24; Resp’t Reply Br. 4–6, 24; II Tr. 28:14–29:7, 31:8–21.)
The Commission, however, has rejected such arguments. See CONSOL Pa. Coal
Co., 44 FMSHRC 691, 696 (Dec.
2022) (holding “[w]hether or not abatement occurs has no bearing on the
underlying violation . . . .”); Western Indus. Inc., 25 FMSHRC 449,
453 (Aug. 2003) (holding the abatement method is irrelevant in determining
whether a violation occurred). Though Inspector Jack observed that the
approximately one-foot-tall bridge is “still a little rough,” he opined “it’s a
lot better than the condition we found.” (Tr. 139:19–140:17.) Indeed, CONSOL’s
witness Steven Barr confirmed that he had used similar “rock dust bag” bridges
in the past. (II Tr. 28:1–11.) Creating a bridge over the hoses, as well as rerouting
the lifeline into Crosscut 15.5 to reduce tripping hazards and maintain a safe passageway
out of the mine, improved the conditions along the escapeway that miners would
encounter in the event of an emergency. Thus, I reject CONSOL’s argument that abatement
failed to reduce the hazard, and I find CONSOL’s other arguments altogether unpersuasive.
In considering the fact of a violation, I found Inspector Jack’s testimony at hearing to be well reasoned and based upon his many years of experience as a miner and as an inspector of underground coal mines. In applying the facts to the applicable standard and Commission case law, I determine that CONSOL violated section 75.380(d)(1). The pump car hoses were situated in such a way as to impede safe passage of persons, including disabled persons, from expeditiously escaping the mine through the No. 2 Entry (escapeway) during emergency conditions. Therefore, I conclude that CONSOL violated section 75.380(d)(1) by failing to maintain the escapeway in a safe condition to always assure passage of anyone.
B. Significant and Substantial Determination
A violation is S&S “if, based upon
the particular facts surrounding that violation, there exists a reasonable
likelihood that the hazard contributed to will result in an injury or illness
of a reasonably serious nature.” Cement Div., Nat’l Gypsum Co., 3 FMSHRC
822, 825 (Apr. 1981). To establish an S&S violation, the Secretary must
prove:
(1) the underlying violation of a mandatory safety standard; (2) the violation was reasonably likely to cause the occurrence of the discrete safety hazard against which the standard is directed; (3) the occurrence of that hazard would be reasonably likely to cause an injury; and (4) there would be a reasonable likelihood that the injury in question would be of a reasonably serious nature.
- *
Peabody Midwest Mining, 42 FMSHRC 379, 383 (June
2020) (citing Newtown Energy, 38 FMSHRC [2033,
2037–38 (Aug. 2016)]); Mathies Coal
Co., 6 FMSHRC 1, 3–4 (Jan. 1984) (footnote omitted); see also Buck Creek
Coal, Inc. v. Fed. Mine Safety & Health Admin., 52 F.3d 133, 135–36
(7th Cir. 1995) (affirming the application of the Mathies criteria); Austin
Power, Inc. v. Sec’y of Lab., 861 F.2d 99, 103–04 (5th Cir. 1988) (affirming
the application of the [Mathies criteria]).
1.
Underlying Violation of a Mandatory Safety Standard
To establish the first element of
the Mathies test, the Secretary must prove an underlying violation of a
mandatory safety standard. I have determined that CONSOL violated section 75.380(d)(1),
because it failed to maintain the secondary escapeway in a safe condition to
always assure passage of anyone, including disabled persons, and assure
expedient passage in the event of an emergency. See discussion supra
Part IV.A. Thus, I determine that the Secretary has satisfied the first element
of the Mathies test.
2.
**Likelihood of Causing the
Occurrence of the Discrete Safety Hazard Against **
Which the
Standard Is Directed
For the
second Mathies element, the Secretary must establish that “there exists
a reasonable likelihood of the occurrence of the hazard against which the
mandatory safety standard is directed.” Newtown Energy, 38 FMSHRC 2033,
2038 (Aug. 2016). Here, the hazard is the possibility of miners tripping on or
falling over the hoses in the escapeway during an emergency, resulting in injury
and/or delayed exit from the mine. (Tr. 129:17–24.) The relevant analysis is
whether miners could expeditiously traverse the hoses during emergency conditions.
See Spartan Mining Co., 35 FMSHRC 3505, 3508–09 (Dec. 2013) (holding
that S&S for escapeway citations must be considered in the context of an
emergency in affirming the ALJ’s determination of significant and substantial
violation of 30 C.F.R. section 75.380(d)(1)).
Inspector Jack attested that during emergencies miners act unpredictably,
and emergencies alter the environmental conditions that miners face. (Tr.
107:12–13, 123:9–11.) Specifically, Inspector Jack stated that during emergency
situations, miners may panic. (Tr. 107:12–13, 123:9–11.) He stated, “[w]hen
you’re in an emergency event like that people act differently. They don’t think
straight. They’re in a panic. The only thing they want to do is get out . . . that
could lead to people running, pushing, shoving” which “sometimes . . . come[s]
at the cost of other individuals who are escaping” at the same time. (Tr.
125:4–17.) CONSOL’s witness Steven Barr[8]
noted miners may temporarily lose their sense of hearing (II Tr. 49:2–22) and
did not dispute the hoses could impede miners. (II Tr. 49:23–54:11.) Miners
feel disoriented (Tr. 108:9–14), panic (Tr. 107:12–13, 123:9–11), feel confused
(Tr. 257:9–12), or may lose their vision due to blackout conditions.
Inspector Jack has worked for over twenty-four years in the mining industry. (Tr. 38:17–20.) He has worked for MSHA for the last 15 years, including eight years as a coal mine inspector and seven years as a roof control specialist. (Tr. 29:7–30:17.) Before his employment with MSHA, Inspector Jack worked at CONSOL’s Enlow Fork Mine as an underground miner for approximately eight years (Tr. 32:1–2, 33:14–19), including working on longwalls and on the installation of a bridge over pump car hoses. (Tr. 191:10–192:12.) For his General Mine Service training, Inspector Jack received instruction on emergencies, escapeways, and navigating the mine. (Tr. 32:20–33:12.) Considering Inspector Jack’s extensive experience and credible insights on the witness stand, I give great weight to his testimony.
CONSOL argues that miners would know of the hoses in Crosscut 15.5 and be able to navigate them. (Resp’t Post-hr’g Br. 22.) But according to Inspector Jack, miners escaping an emergency situation would likely be panicky and somewhat disoriented (Tr. 107:12–13, 108:9–14, 123:9–25, 249:20–23, 257:9–12) and would not likely know they were approaching the hoses at Crosscut 15.5. (Tr. 153:1–157:25, 224:15–225:7; Ex. R–7; Resp’t Post-hr’g Br. 8, 9, 22.) The miners would be tethered together and would contact the protruding hoses at heights of 12” to 29” off the mine floor. Inspector Jack, who is 5’10” tall (Tr. 78:17–79:2, 169:6–8), observed that the suspended 29” hose reached his mid-thigh, the 15” hose hung just below his kneecap, and the twelve-inch hose hung mid-shin. (Tr. 80:6–19.) Therefore, the positions of the hoses would likely trip miners and, as Inspector Jack observed, the “first miner in the [line] would hit these hoses, would trip, would pull two or three miners behind him over as he falls.” (Tr. 104:11–24, 107:9–22.) Because miners are tethered together, when one miner falls, other miners will “stack,” where one miner falls and the next falls on top of the first miner, and the chain reaction continues. (Tr. 122:21–123:2, 124:1–15.)
Even if the miners successfully navigate past one of the hoses, the miners must successfully traverse over five more hoses of differing heights spanning six feet of the escapeway (Tr. 82:8–10, 83:6–10), like hurdling at a track meet. Any one of the obstructions could reasonably trip up any of the individual miners, likely bringing down other miners and delaying the entire group. When miners fall, they may sustain injuries from the fall itself. (Tr. 107:23–108:14.) Even if they were to come through a fall unscathed, a miner’s SCSR could be torn from their face by the force of the fall or collision with other miners, or they could let go of and lose the lifeline. (Tr. 108:9–14, 128:23–25.) Any of these scenarios would delay the miners from expeditiously escaping the mine. Miners losing hold of the lifeline would likely lose time struggling to find it again due to poor visibility or being disoriented and, if they were lucky enough to find the lifeline, would nonetheless lose time feeling around in the dark searching for it. (Tr. 108:9–14.) Any delay from stumbling or searching for the lifeline or short-term SCSR could prevent a miner from reaching the cache of long-term SCSRs before running out of time on the ten-minute SCSR they originally donned. (Tr. 125:22–126:3, 128:21–22.)
CONSOL posits that an emergency
would not likely occur because Inspector Jack found no raised methane levels at
the time of his inspection. (Tr. 197:25–198:7; see Exs. R–3, R–4.) However,
the Commission has found the lack of raised methane levels irrelevant to the
S&S analysis because the existence of an emergency is assumed. [Cumberland Coal Res., 33 FMSHRC 2357, 2366 (Oct.
2011)] (overturning ALJ’s non-S&S determination for violations of the evacuation
standard under section 75.380(d)(7)(iv) where ALJ improperly considered
testimony regarding the likelihood of a mine fire or explosion).
CONSOL attempts
to focus this case on the lifeline. (Resp’t Post-hr’g Br. 5–6, 8, 11.) As
discussed above, the lifeline is irrelevant to the fact of a violation under
section 75.380(d)(1). Yet, the Commission does consider the positioning of a
lifeline in relation to the escapeway when analyzing whether an escapeway
violation is S&S. See Mill Branch Coal Corp., 37 FMSHRC 1383, 1394
(July 2015) (considering fact that obstructions were directly under the
lifeline in upholding as S&S a violation of section 75.380(d)(1)). Here,
the lifeline hung directly above the pump car hoses. (Tr. 79:9–21.) [Miners could not circumvent the hoses without letting go
of the lifeline because the lifeline contained little slack and was “bow string
tight.” (Tr. 79:13–21, 259:5–20.)]Thus, miners could not both hold onto the
lifeline—the “saving grace to getting outside”—and circumvent the hoses. (Tr.
130:16–19; see Resp’t Post-hr’g Br. 4.)
Given the
record as a whole, I determine it is reasonably likely that miners—tethered
together in emergency conditions—would trip or fall over the hoses impeding
their passage, which would delay their quick exit from the mine. Therefore, I
determine the violation
was reasonably likely to cause the occurrence of the discrete safety hazard
against which the standard is directed, and
the Secretary has satisfied the second element of Mathies.
3.
Likelihood the Occurrence of the Hazard Would Cause Injury
Regarding the
third Mathies element, the Secretary must demonstrate a reasonable
likelihood that the occurrence of the hazard would result in an injury. Inspector
Jack stated, and CONSOL’s witnesses did not refute, that tripping over the
hoses, would “reasonably likely cause an accident, and that would be a trip and
fall, breaking bones, tearing a rescuer off, sprains, [and] strains.” (Tr. 104:25–105:3,
107:9–22, 108:1–2, 121:15–122:2, 151:16–17.) Inspector Jack also noted that
mine disasters, whether it be a fire or explosion, emit high concentrations of
carbon monoxide. (Tr. 122:4–5, 123:9.) If a miner loses his SCSR, even for a
short period, the miner could reasonably “be
overcome by carbon monoxide before they’re ever able to recover their mask,” (Tr.
122:4–16) especially if compounded by mobility issues such as broken limbs, torn
ligaments, or disorientation from losing the lifeline. (Tr. 104:25–105:3, 107:9–22,
108:1–2, 121:15–122:2, 129:1–10, 151:16–17.) Losing the lifeline or a SCSR
would also prevent a miner from reaching the next cache of longer-use SCSRs. (Tr.
105:3–5, 129:1–10.) Therefore, even if a miner sustained no immediate injuries
during the fall, delayed escape causes a miner to use up more oxygen or breathe
in more noxious gases than they would with a more expedient escape, and lose
valuable time needed to get to the cache of long-term SCSRs. Consequently, I
determine that tripping on or falling over the hoses themselves contributes to
an injury or delayed escape, particularly for disabled miners, and the
resulting delay is reasonably likely to lead to injury, thus satisfying the
third element of the Mathies test.
4.
Likelihood Resulting Injury Would Be of Reasonably Serious Nature
Lastly, under
the fourth Mathies element, the Secretary must prove a reasonable
likelihood that the resulting injury would be of a reasonably serious nature. An
injury of a “reasonably serious nature” does not require a specific type of
injury, and a mere sprain or strain resulting from a trip and fall may be
“reasonably serious.” S & S Dredging Co., 35 FMSHRC 1979, 1981–82
(July 2013) (holding the ALJ erred in requiring the Secretary to demonstrate an
injury that would result in hospitalization, surgery, or a long period of
recuperation to satisfy the fourth Mathies element); see, e.g., Maple
Creek Mining, Inc., 27 FMSHRC 555, [562–63] (Aug.
2005) (affirming the ALJ’s determination that reasonably serious injury, such
as a leg or back injury, would reasonably arise from the failure to maintain
the walkway in a safe condition); Southern Ohio Coal Co., 13 FMSHRC
912, 918 (June 1991) (affirming ALJ’s conclusion that a trip-and-fall would
result in reasonably serious injuries such as “sprains, strains
or fractures”).
CONSOL’s witnesses did not dispute
Inspector Jack’s testimony that injuries would likely include broken bones,
sprains, strains, torn ligaments, or fatality (Tr. 105:1–11, 109:9–22, 129:1–10,
151:16–25), which all are of a reasonably serious nature. If a miner loses his SCSR
in a fall, he is reasonably likely to inhale and succumb to poisonous gases on
the spot. (Tr. 104:25–105:3, 107:9–22, 108:1–2, 121:15–122:2, 151:16–17.) Otherwise,
if the miner gets disoriented, loses the lifeline, and cannot find the mine exit
or is delayed in exiting and cannot reach the cache of long-term SCSRs in
sufficient time with the oxygen he has, the miner
is reasonably likely to die—or, in Inspector Jack’s words, is “done”—due to
inhalation of the poisonous gases. (Tr. 104:25[–]105:3,
107:9–22, 108:1–2, 121:15–122:2, 151:16–17.) I determine that the injuries
expected to result from tripping on the hoses or delayed escape are reasonably
likely to be of a reasonably serious nature, thus satisfying the fourth Mathies
element. For the same reasons, I affirm the
Inspector’s gravity determination as reasonably likely to result in lost
workdays or restricted duty.
Accordingly, the Secretary has
satisfied all four elements of the Mathies test. I conclude that
Citation No. 9204482 is appropriately designated as S&S.
**C. Negligence **
Commission Judges determine
negligence under a traditional analysis rather than relying on the Secretary’s
regulations at 30 C.F.R. § 100.3(d). Mach Mining, LLC v. Sec’y
of Lab., 809 F.3d 1259, 1264 (D.C. Cir. 2016) (quoting Brody Mining, LLC,
37 FMSHRC 1687, 1701 (Aug. 2015)). This analysis
asks whether an operator has met “the requisite standard of care—a standard of
care that is high under the Mine Act.” Id. In evaluating these
factors, the negligence determination is based on the “totality of the
circumstances holistically,” including factors such as the protective purpose
of the regulation, and what actions would be taken by a reasonably prudent
person familiar with the mining industry. Mach Mining, 809 F.3d at 1264
(quoting Brody Mining, LLC, 37 FMSHRC at 1702).
Inspector Jack assigned moderate
negligence to Citation No. 9204482. (Tr. 101:2–4, 130:20–131:9.) At hearing,
the Secretary argued the record may show high negligence and asserts in her
post-hearing brief that the “violation resulted from at least moderate
negligence.” (Sec’y Post-hr’g Br. 22–23; Tr. 21:10–19.) In
support, the Secretary asserts CONSOL knew or should have known about the
obstructions in the escapeway. (Tr. 130:23–25, 132:3–11; Sec’y Post-hr’g Br.
23.) CONSOL was cited under the same
standard at Enlow Fork Mine in the past two years (II Tr. 53:11–14), which the Secretary
argues should have put CONSOL on notice that the
condition in this citation violates the mandatory safety standard. (Sec’y
Post-hr’g Br. 23; see Ex. P–5.) The hoses protruded from the pump
car at the cited location from approximately August 12–17, 2021. (Tr. 132:7–15,
148:8–24, 269:13–270:12; II Tr. 43:6–44:7, 54:6–11; Ex. R–6 at 49.) Since a
mine examiner was required to inspect the entire track at least three times a
day—before each shift—CONSOL’s mine examiner thus had multiple opportunities to
observe the condition but did not make any notations concerning the cited
condition. (Tr. 134:13–15, 148:8–24, 264:25–265:8, 269:13–270:12; II Tr. 36:9–38:2;
Exs. P–3, R–2.) Further, CONSOL’s witness Steven Barr previously constructed
bridges to cover hoses in an alternate escapeway and therefore knew of this
safer option. (II Tr. 28:1–11.) Inspector Jack observed that placing the hoses
in the cited condition was “very avoidable” because CONSOL could run the
lifeline on the opposite side of the pump cars and power centers, where no
hoses laid across the escapeway. (Tr. 146:7–15, 148:8–24.) CONSOL argues that
no negligence is appropriate, claiming it did not breach the standard of care
but does not give specific facts to support its position. (Tr. 23:13–14, 27:4–6;
Resp’t Post-hr’g Br. 25.) I determine
that CONSOL should have known of the violative condition, and that this violation
runs on the high end of moderate negligence. Considering the totality of the
circumstances, I conclude that a designation of moderate negligence is
appropriate.
D. Penalty
The Secretary proposes a penalty of
$2,844.00. [The Commission is not bound by the
Secretary’s proposal and reviews penalty assessments de novo].
CONSOL is a large operator with a low to moderate violation history. In the two years preceding the issuance of this citation, MSHA issued one violation of section 75.380(d)(1) to CONSOL’s Enlow Fork Mine that became a final order of the Commission. (Ex. P–5 at 3.) I determined CONSOL’s negligence to be moderate. CONSOL has not alleged that the proposed penalties would adversely affect its ability to continue in business. I also determined the gravity of the violation to be S&S. Finally, CONSOL demonstrated good faith by quickly moving the escapeway’s footpath into the crosscut and constructing a “rock dust bag” bridge over the hoses to comply with the cited standard. (Tr. 93:17–22, 135:12–141:22, 148:5–13, 177:15–24; II Tr. 57:10–11; Ex. P–1.) In considering the criteria set forth in section 110(i) of the Mine Act and all the relevant facts, I hereby assess a penalty of $2,844.00.
V. ORDER
In light of the foregoing, it is
hereby ORDERED that Citation No. 9204482 is
AFFIRMED as written.
Respondent CONSOL Pennsylvania Coal Company, LLC
is hereby ORDERED to PAY a penalty of $2,844.00 within 40 days of
this decision.[9]
/s/
Alan G. Paez
Alan G. Paez
Administrative Law Judge
Distribution: (Via U.S. Mail and Electronic Mail)
[Sharon H. McKenna, Esq., U.S.
Department of Labor, Office of the Regional Solicitor,]
1835 Market Street, Mailstop SOL/22, Philadelphia, PA 19103-2968
Patrick W. Dennison, Esq., Fisher & Phillips LLP, 6 PPG Place, Suite 830, Pittsburgh, PA 15222-5428
/gw
[1] In this decision,
the original hearing transcript, the supplementary hearing transcript, the
Joint Exhibit, the Secretary’s exhibits, and the Respondent’s exhibits are
abbreviated as “Tr.,” “II Tr.,” “Jt. Ex. #,” “Ex. P–#,” and “Ex. R[–]#,” respectively.
[2] The S&S
terminology comes from section 104(d)(1) of the Mine Act, 30 U.S.C. § 814(d)(1),
which distinguishes as more serious any violation that “could significantly and
substantially contribute to the cause and effect of a . . . mine safety or
health hazard . . . .” 30 U.S.C. § 814(d)(1).
[3] The parties
incorrectly list this as a “Contest” proceeding in Item 4 of their stipulations.
[4] The photographs
in Exhibit R–5 do not depict the cited condition and were not taken the day the
citation was issued. They were entered into evidence to show a “general idea”
of similar conditions, and depict, among other conditions, high pressure hoses
protruding into a track entry. (Tr. 12:19–14:16, 225:18–232:12; Ex. R–5.)
[5] CONSOL submitted its
Examination of Electrical Equipment and the Longwall Section On-shift Dust
Parameter Examination Record. ([Exs. R–3, R–4.]) While
coal dust and electrical equipment maintenance may affect the likelihood of an
emergency, this information does not affect my analysis of the existence of a
violation because emergency conditions are assumed. Am. Coal Co., 29
FMSHRC at 950.
[6] The citation’s
focus is properly on the obstruction as evident by the way Inspector Jack
allowed CONSOL to abate the citation. The abatement focused on the obstruction
of passage, which corresponds to the proper standard: section 75.380(d)(1). CONSOL
laid bags filled with rock dust between the hoses to create a bridge to
eliminate or reduce any tripping hazard and redirected the lifeline into
Crosscut 15.5 where the hoses laid flat on the mine floor, allowing miners to
safely use the passageway. (Tr. 93:17–22, 135:12–141:22; Ex. P–1.)
[7] Section 75.380(d)(4)(iv)
states: “Each escapeway shall be maintained
at least 6 feet wide except where mobile equipment near working sections, and
other equipment [essential to the ongoing operation of
longwall sections], is necessary during normal mining operations, such as
material cars containing rock dust or roof control supplies, or is to be used for the
evacuation of miners off the section in the event of an emergency. In any
instance, escapeways shall be of sufficient width to enable miners, including
disabled persons, to escape quickly in an emergency. When there is a need to
determine whether sufficient width is provided, MSHA may require a stretcher
test where 4 persons carry a miner through the area in question on a stretcher.”
30 C.F.R.
§ 75.380(d)(4)(iv).
[8]
Barr has worked in many different positions in his twenty-one years with
CONSOL, including stints as longwall coordinator and general mine foreman. (II Tr.
5:17–7:1.)
[9] Please pay penalties electronically at Pay.Gov, a service
of the U.S. Department of the Treasury, at https://www.pay.gov/public/form/start/67564508. Alternatively, send payment (check or money order) to:
U.S. Department of Treasury, Mine Safety and Health Administration P.O. Box
790390, St. Louis, MO 63179-0390. Please include Docket and A.C. Numbers.
Get today's answer for your situation
You just read what one judge decided for one employer in 2023, and it binds only those parties. Ezel checks the current MSHA standards and Commission precedent and answers your specific situation, with citations.
Opens in Ezel Pro. Every answer cites the authority it relies on.