Excel Mining, LLC (ALJ decision, April 2, 2009)
Excel Mining, LLC (FMSHRC KENT 2008-122): Damaged roof-bolter cable was significant and substantial
Apply this to your situation
This order from 2009 bound only the parties to this case; it isn't precedent. Ask about your situation and see what the current MSHA standards and Commission precedent say, with citations.
Plain-English summary
MSHA cited Excel Mining after an inspector found a three-inch damaged area in the outer insulation of a 575-volt roof-bolter cable at the underground Van Lear Mine. Excel stipulated that the condition violated the requirement that power cables be adequately insulated and fully protected, but disputed the significant and substantial designation. The judge found that the torn outer jacket contributed to an electrical-shock hazard even though the visible inner conductors remained insulated. Applying Commission precedent about trailing cables in the harsh mining environment, he concluded that weakening the cable's outer protection made a serious electrical injury reasonably likely. The judge affirmed the violation as significant and substantial and assessed a $1,657 penalty.
Decision snapshot
- Cited standard: 30 C.F.R. § 75.517
- Outcome: The violation and its significant and substantial designation were affirmed, with a $1,657 penalty.
- Key point: An intact inner layer did not defeat the significant and substantial finding because damage to the outer cable jacket weakened protection against electrical shock.
Full text (FMSHRC public release)
FMSHRC ALJ Decision
FEDERAL MINE SAFETY AND HEALTH REVIEW COMMISSION
OFFICE OF ADMINISTRATIVE LAW JUDGES
601 NEW JERSEY AVENUE, N.W., SUITE 9500
WASHINGTON, DC 20001-2021
TELEPHONE: 202-434-9964 / FAX: 202-434-9949
April 2, 2009
SECRETARY OF LABOR,
MINE SAFETY AND HEALTH
ADMINISTRATION (MSHA),
Petitioner
v.
EXCEL MINING, LLC,
Respondent
:
:
:
:
:
:
:
:
:
CIVIL PENALTY PROCEEDING
Docket No. KENT 2008-122
A.C. No. 15-18839-128465
Van Lear Mine
DECISION
Appearances: Thomas Grooms, Esq., Office of the Solicitor, U.S. Department of Labor, Nashville, Tennessee, for the Petitioner;
Noelle Holladay True, Esq., Rajkovich, Williams, Kilpatrick & True, PLLC, Lexington, Kentucky, for the Respondent.
Before: Judge Weisberger
Statement of the Case
This case is before me based upon a Petition for a Civil Penalty filed by the Secretary of Labor, pursuant to Section 105(d) of the Federal Mine Safety and Health Act of 1977 (“The Act”), alleging that Excel Mining, LLC (“Excel”), violated 30 C.F.R. § 75.517, and seeking the imposition of a civil penalty for this violation.
On August 2, 2007, Mine Safety and Health Administration (MSHA), inspector David Stepp, inspected Excel’s Van Lear Mine, an underground coal mine. In the course of his examination of a trailing cable of a roof bolter, he observed a damaged portion of the outer insulation that was approximately three inches long, and a half to one inch wide. Three inner insulated wires carrying 575 volts could be seen, but there was not any visible damage. Stepp issued a citation alleging a violation of Section 75.517, supra, which, as pertinent, provides as follows: “power wires and cables ... shall be insulated adequately and fully protected.”
A hearing was held in the this matter on November 13, 2008. On February 23, 2009, the Secretary filed Proposed Findings of Fact, Brief and Argument, and Excel filed a Post Hearing Brief. On March 3, 2009 Excel filed a Reply Brief.
Findings of Fact and Discussion
At the hearing, the parties filed a set of ten stipulations. Respondent, inter alia, stipulated to a violation of Section 517, supra. Thus, considering this stipulation and the record in this case, I find that Excel did violate Section 517, supra.
The citation at bar was issued as being significant and substantial. In general, Commission law regarding significant and substantial is well established and is as follows:
A "significant and substantial" violation is described in section 104(d)(1) of the Mine Act as a violation "of such nature as could significantly and substantially contribute to the cause and effect of a coal or other mine safety or health hazard." 30 U.S.C. § 814(d)(l). A violation is properly designated significant and substantial "if based upon the particular facts surrounding the violation there exists a reasonable likelihood that the hazard contributed to will result in an injury or illness of a reasonably serious nature." Cement Division, National Gypsum Co., 3 FMSHRC 825 (April 1981).
In Mathies Coal Co., 6 FMSHRC 1, 3-4 (January 1984), the Commission explained its interpretation of the term "significant and substantial" as follows:
In order to establish that a violation of a mandatory
safety standard is significant and substantial under National Gypsum the Secretary of Labor must prove: (1) the underlying violation of a mandatory safety standard; (2) a discrete safety hazard--that is, a measure of danger to safety--contributed to by the violation; (3) a reasonable likelihood that the hazard contributed to will result in an injury; and (4) a reasonable likelihood that the injury in question will be of a reasonably serious nature.
In United States Steel Mining Company, Inc., 7 FMSHRC 1125, 1129 (August 1985), the Commission stated further as follows:
We have explained further that the third element of the
Mathies formula "requires that the Secretary establish a
reasonable likelihood that the hazard contributed to will
result in an event in which there is an injury." U. S. Steel Mining Co., 6 FMSHRC 1834, 1836 (August 1984). We have emphasized that, in accordance with the language of section 104(d)(1), it is the contribution of a violation to the cause and effect of a hazard that must be significant and substantial. U. S. Steel Mining Company, Inc., 6 FMSHRC 1866, 1868 (August 1984); U. S. Steel Mining Company, Inc., 6 FMSHRC 1573, 1574-75 (July 1984).
The record clearly establishes, as set forth above, that the violative condition of the damaged outer insulation of the cable exposed three inner insulated wires carrying 575 volts, which contributed to the hazard of electrical shock or injury. Accordingly, I find that the first and second factors set forth in Mathies, supra, have been met. The critical issue for resolution is whether the third element of Mathies, supra, has been established i.e., the reasonable likelihood of an injury producing event.
Excel argues, inter alia, that, as conceded by Stepp, a person would not receive any electrical shock when all the inner conductors are still insulated. In this connection, Excel cites Stepp’s testimony that he did not observe any damage to the inner conductors. Excel also cites the testimony of Michael Hurley, Excel’s shift foreman, that with continued normal mining operations in the entry at issue, the damaged portion of the cable would not have been handled.
In U.S. Steel, 6 FMSHRC 1573 (July 1984), the operator challenged the decision of the judge that a gash in the outer insulating jacket of a trailing cable in addition to being a violation of Section 517, supra, was also significant and substantial. The Commission, in affirming the decision of the judge with regard to significant and substantial held as follows:
The administrative law judge considered those mining conditions to which the damaged cable predictably would be exposed. He found that both the outer and inner layers of insulation provided important protection against electrical shock. These findings are fully supported by the testimony of the MSHA inspector and the operator’s witness, each of whom stated that the mining environment is harsh and that damage to the outer layer of insulation weakened the protection afforded by the inner layer.
U.S. Steel, supra, at 1575.
In Harlan Cumberland Coal Co., 20 FMSHRC 1275, 1284-1286 (December 10, 1998), an issue presented to the Commission was whether a violation of 30 C.F.R. § 75.604(b)
i.e., that
splices on a cable were not “effectively insulated” to exclude moisture, was significant and substantial. The operator therein argued that the third element of Mathies, supra, was not established by the Secretary , since there were not any exposed leads, and that the Secretary failed to prove “that anyone was or would be exposed to electrical current by handling the cable.” 20 FMSHRC, supra, at 1285. It is significant that in rejecting this argument, the Commission relied on U.S. Steel, supra, and analyzed the holding in U.S. Steel, supra, as follows: “... In U.S. Steel Mining Co., [citations omitted] we held that four inches of exposed wire constituted an S&S violation, despite lack of direct evidence that exposed wires were not insulated.” 20 FMSHRC, supra, at 1286. The Commission also cited U.S. Steel supra, as “recognizing that a tear in the outer jacket of a cable significantly compromises the cable’s protective function.” (Id.) (emphasis added)
The Commission, in applying U.S. Steel, supra, to the evidence of record, cited the testimony of the inspector who “emphasized the danger of these situations [his inability to see bare conductors inside the open splice of the cable], stating that ‘there’s no way of knowing
[whether there are holes in the insulation surrounding the wire within the cable].’”(Id). The Commission also noted the inspector’s testimony that “even if no copper wires are exposed, there is a danger of electrocution, because ‘[m]uch like an extension cord with a naked place you may not be able to see the naked place, but you grab a hold of it and you’ll know it.’”(Id.).
The Commission concluded that the record supported the judge’s finding that the violation was S&S, as it was reasonably likely to contribute to a serious electrical injury.
In Harlan, supra, the Commission was also presented with the specific issue of whether the third Mathies, element was established regarding a violation of Section 517, supra. i.e., a visible rupture in the outer jacket of the training cable of a bolter which exposed the inner insulated conductors. The Commission held that the operator’s argument that reasonable likelihood of injury cannot be established if there is not direct evidence of damaged interior conductors or proof of the existence of exposed uninsulated wire “... is inconsistent with Commission precedent.” Harlan, supra, at 1287. (Emphasis added) In this connection, the Commission noted that in U.S. Steel, supra, where the parties agreed that the outer jacket had ruptured, but that there was not any evidence that the inner insulation was compromised, “we held that the gash in the outer jacket of the trailing cable constituted an S&S violation of section 517, in part because in the ‘harsh environment of a coal mine’ a tear in the outer jacket weakens the protection afforded by the inner insulation, ‘contribut[ing] significantly and substantially[] to the cause and effect of a safety hazard’ Id. at 1574-75.” (Id)
In Harlan, supra, the Commission noted that the condition of the cable at issue i.e., the outer jacket was torn but there was not any direct evidence that the inner insulation was damaged, was similar to the condition of the cable at issue in U.S. Steel, supra. The Commission found U.S. Steel, supra, persuasive in the matter before it, and affirmed the judge’s determination of S&S.
In the case at bar, as in Harlan, supra, there is not any dispute that the outer jacket of the cable, which constituted a layer of insulation between the miners and a potentially fatal 550 volt current, was torn.
I find that the physical condition of the cited cable was similar to that of the cables at issue in Harlan, supra, and U.S. Steel, supra, whichwere found to be S&S, in light of, inter alia, the harsh environment of a coal mine. Since I am bound to follow established Commission case law, I find, based on U.S. Steel, supra, and Harlan Cumberland, supra, that the violation herein was significant and substantial.
Penalty
The record does not contain any evidence that Excel’s history of violations is such as to have either a positive or negative effect on the level of penalty to be imposed. The parties stipulated that the penalty proposed by the Secretary is appropriate to the size of Excel’s business, and will not affect its ability to continue in business.
The Secretary argues that the level of Excel’s negligence was moderate given the fact that the damage to the cable was obvious and that the history of violations of Sections 75.517, supra, and 75.604, supra, was “very” significant.
Excel did not impeach or contradict Stepp’s
testimony that the damage was obvious. However, it is significant that Stepp indicated that he noted the damage as he was running his hand over the cable. There is not any evidence as to when the cable had last been touched by Excel’s employees or agents. Nor is there any evidence in the record that prior to its being cited, the damage to the cable was obvious to visual observation. Further, there is not any evidence in the record as to when the cable was damaged, especially in relation in time to the inspection by Stepp. Thus, it cannot be concluded that Excel had knowledge or notice of the cited condition prior to the inspection.
The parties stipulated that Excel demonstrated good faith in attempting to achieve rapid compliance after notification of the violation.
For the reasons set forth above, I find that the gravity of the violation was high as it could have resulted in a fatality.
Considering all of the above factors set forth in Section 110(i) of the Act, and placing emphasis on the high level of gravity, I find that a penalty of $1,657 is appropriate.
ORDER
It is Ordered that, within thirty days of this decision, Excel pay a penalty of $1,657 for the violation of 75.517, supra.
Avram Weisberger
Administrative Law Judge
202-434-9940
Distribution:
Tom Grooms, Esq., Office of the Solicitor, U.S. Department of Labor, 618 Church Street, Suite 230, Nashville, TN 37219-2456
Noelle Holladay True, Esq., Rajkovich, Williams, Kilpatrick & True, PLLC, 2333 Alumni Park Plaza, Suite 310, Lexington, KY 40517
/lp