Allstate Roofing, Inc. (ALJ decision, January 10, 1994)
Willful roof-fall violation affirmed with reduced penalty
Apply this to your situation
This order from 1994 bound only the parties to this case; it isn't precedent. Ask about your situation and see what the current OSHA standards and Commission precedent say, with citations.
Plain-English summary
Allstate Roofing had about five employees working on a nearly flat roof that measured 200 by 120 feet and was 20 feet above the ground. OSHA observed employees without the fall protection required for built-up roofing work, including one worker who came within about three feet of an unguarded edge. The judge rejected Allstate's infeasibility defense because the company admitted compliance was possible and did not show that guardrails, warning lines, or the other specified systems were infeasible. He also found that one safety monitor could not provide equivalent protection across the large roof, especially with mechanical equipment and noise present. The violation was willful because Allstate knew the rule from three prior citations and OSHA explanations but deliberately substituted its own procedures based on an unreasonable reading of the standard. The judge affirmed the willful violation but reduced the proposed penalty from $28,000 to $12,000 because the likelihood of an accident was low.
Decision snapshot
- Cited standard(s): 29 C.F.R. § 1926.500(g)(1).
- Outcome: Modified. The willful violation was affirmed, but the proposed penalty was reduced to $12,000.
- Key point: Repeated notice of a clear fall-protection rule can support willfulness when an employer knowingly substitutes a noncompliant system.
Full text (OSHRC public release)
UNITED STATES Of AMERICA
OCclJPATlONAL SAFETY AND HEALTH REVIEW cohdfb!lSs~ON One Lafayette Centre
1120 20th Street, N.W. - 9th Floor
Washington, DC 20036-3419
\ /
PHONE: .
COM (202j 60641~
f
Frs (202) aobalrn
,
SECRETARY OF LABOR
Complainant,
v. OSHRC DOCKET
NO. 93-0832
ALLSTATE ROOFING, INC.
Respondent.
NQTICE OF DOCKETING
OF ADMINISTRATIVE LAW JUDGE’S DECISION
The Administrative Law Judge’s Report in the above referenced case was docketed with the Commission on December 10, 1993. The decision of the Judge will become a final order of the Commission on January 10, 1994 unless a Commission member directs review of the decision on or before that date. ANY PARTY DESIRING REVIEW OF THE JUDGE’S DECISION BY THE COMMISSION MUST FILE A PETITION FOR DISCRETIONARY REVIEW.
Any such petition should be received by the Executive Secretary on or before December 30, 1993 in order to permit sufficient time for its review. See Commission Rule 91, 29 C.F.R. 2200.91.
All further pleadings or communications regarding this case shall be addressed to:
Executive Secretary
Occupational Safety and Health
Review Commission
1120 20th St. N.W., Suite 980
Washington, D.C. 20036-34 19
Petitioning parties shall also mail a copy to:
Daniel J. Mick, Esq.
Counsel for Regional Trial Liti ation
Office of the Solicitor, U.S. DO5
Room S4004
200 Constitution Avenue, N.W.
Washington, D.C. 20210
If a Direction for Review is issued by the Commission, then the Counsel for Regional Trial Litigation will represent the Department of Labor. Any party havmg questions about review rights may contact the Commission’s Executive Secretary or call (202) 606-5400.
Date: December 10, 1993
Ray H.
Execu Pve
DOCKET NO. 93-0832
NOTICE IS GIVEN TO THE FOLLOWING:
Daniel J. Mid, @@F
Counsel for Re Trial Liti ation
Office of the SOF *&or, U.S. DOc
Room S4004
200 Constitution Ave., N.W.
Washington, D.C. 20210
Tedrick House, Esq.
Re ional Solicrtor
Of&e of the Solicitor U S DOL
Federal Office Bldg., ko& 2106
911 Walnut Street
Kansas City, MO 64106
Vanessa M. Ceravolo, Esquire
P. 0. Box 1197
Kalispell, MT 59903 1197
James H. Barkley
Administrative Law Jud e
Occupational Safety an d Health
Review Commission
Room 250
1244 North S eer Boulevard
Denver, CO tr0204 3582
00111625097:08
UNITED STATES OF AMERICA
OCCUPATIONAL SAFETY AND HEALTH REVIEW COMMISSION 1244 N. SPEER BOULEVARD
ROOM 250
DENVER, COLORADO 80204-3582
PHONE
FAX
COM (303) 844-2281
COM (303) 8463759
FE (303) 844-2281
fls (303) 844-3759
SECRETARY OF LABOR,
Complainant,
v. OSHRC DOCKET
NO. 93-0832
ALLSTATE ROOFING, INC.,
Respondent.
APPEARANCES:
For the Complainant:
DeweyP. Sloan, Jr., Esq. Office of the Solicitor, U. S. Department of Labor, Kansas City, Missouri
For the Respondent:
Vanessa M. Ceravolo, Esq., Kalispell, Montana
DECISION AND ORDER
Barkley, Judge:
This proceeding arises under the Occupational Safety and Health Act of 1970 (29 U.S.C., Section 651, et. seq, hereafter referred to as the Act).
Respondent, Allstate Roofing, Inc. (Allstate) at all times relevant to this action,
maintained a place of business at Charles and Monad, Billings, Montana, where it was
engaged in roofing construction. Allstate admits it is an employer engaged in a business affecting commerce and is subject to the requirements of the Act.
On January 19, 1993 the Occupational Safety and Health Administration (OSHA)
conducted an inspection of Allstate’s Charles and Monad worksite (Tr. 17). As a result of the inspection, Allstate was issued a “willful” citation alleging violation of #1926.500(g)(1), together with proposed penalties, pursuant to the Act. By filing a timely notice of contest Respondent brought this proceeding before the Occupational Safety and Health Review Commission (Commission).
On August 19, 1993, a hearing was held in Billings, Montana.
The parties have
submitted briefs on the issues and this matter is ready for disposition.
Alleged Violations
Citation 1, item 1 states:
29 CFR 1926.500(g)(l): Employees engaged in built-up roofing work on low-pitched roofs with a ground to eave height greater than 16 feet were not protected from falling by using one of the methods described in 29 CFR 1926.500(g)(l)(i) through (iii) at all unprotected sides and edges of the roof.
(a) Monad & Charles: Employees working on edge of roof approximately 20 feet above ground level.
The cited standard provides:
(g) Guarding of low-pitched roof perimeters duting the pefoMance of built-up roofing work--( 1) Gerteral provisiom. During the performance of built-up roofing work on low-pitched roofs with a ground to eave height greater than 16 feet (4.9 meters), employees engaged in such work shall be protected from falling from all unprotected sides and edges of the roof as follows:
(i) By the use of a motion-stopping-safety system (MSS system)‘; or (ii) By the use of a warning line system erected and maintained as provided in paragraph (g)(3) of this section and supplemented for employees working between the warning line and the roof edge by the use of either an MSS system or, where mechanical equipment is not being used or stored, by the use of a safety monitoring system; or
(iii) By the use of a safety monitoring system on roofs fifty feet (15.25 meters) or less in width (see Appendix A), where mechanical equipment is not being used or stored.
’ $1926.502(j) defines MSS Systems (motion stopping-safety systems) as “fall protection using the following equipment singly or in combination; standard railings (guardrails) as described in ~1926SOO(f); scaffolds or platforms with guardrails as described in 51926.451; safety nets as described in $1926.105; and safety belt systems as described in 51926.104.
2
Issues
I Whether the Secretary has, by a preponderance of the evidence, made out a prima fHcie case that Allstate violated §1926.5OO(g)(l) on January 19, 1993?
a. Whether, in order to prove a violation of a standard under $5(a)(2) of the Act, the Secretary has the burden of proving the reasonableness of abatement measures specified within cited standards?
II Whether Allstate has shown the infeasibility of abatement measures specified under
§;926.5OO(g)( l)?
III . Whether alternative protective measures taken by Allstate excuse the cited violation?
IV. Whether alternative protective measures taken by Allstate render any violation de minimk?
V Whether Allstate’s violation of 51926.500(g)(l), if any, was correctly classified as Gillful?”
VI . Whether the proposed penalty of $28,000.00 is appropriate?
Facts
On August 19, 1993, following a phone complaint, OSHA Compliance Officer (CO),
Thomas Wild, visited Allstate’s Billings worksite (Tr. 17-18). There Wild observed and videotaped approximately five Allstate employees scattered on the north, east and southeast end of a roof, working without the benefit of fall protection (Tr. 19020,23,55, 59, 171; Exh. C-l through C-6; see also, testimony of James Jones, Tr. 144, 147; Stanley Ludwig, Tr. 155). Specifically, Wild observed one employee walk to within approximately three feet of the unguarded roofs edge to throw down roofing materials (Tr. 24,39,76,158; Exh. C-7, C-8).
Allstate’s safety director evaluates each job site prior to commencement of work, including the pitch of the roof and the ground to eave height.
The rooftop was 20 feet from the eaves to the ground (Tr. 81). It measured 200 feet
long by 120 feet wide (Tr. 91). The roof was nearly flat, with a 1:12 pitch (Tr. 157, 186). Allstate employees were operating drills; there was also a heat welding machine with a generator or compressor running near the center of the roof (Tr. 50-51, 166). CO Wild testified that the site was very noisy; that the compressor noise interfered with conversation
within approximately 30 feet of it (Tr. 50-52).
Discussion
I.
Under Commission precedent,
in order to prove a violation of section 5(a)(2) of the
Act, the Secretary need show only that (1) the cited standard applies, (2) there was a failure to comply with the cited standard, (3) employees had access to the violative condition and (4) the cited employer either knew or could have known of the condition with the exercise of reasonable diligence. See, e.g., Walker Towing Cop., 14 BNA OSHC 2072, 2074, 1991 CCH OSHD 729239, p. 39,157 (No. 87-1359, 1991).
Allstate admits that the single-ply roof system attached with mechanically fastened . screws and heat welded seams at Charles and Monad falls under OSHA’s definition of “built-up roofing”*, governed by s1926SOO(g) (Tr. 83, 113, 135). The ground to eave height was greater than sixteen (16) feet. Allstate’s supervisor and safety director, Michael Phillips further admits that they “did not implement 500(g)” at that location (Tr. 201). The evidence establishes that employees were exposed to the cited condition, and that the employer was
not only aware of those condition, but approved of them. The Secretary has, therefore,
made out her prima facie case.
Allstate argues that the Secretary failed to meet her burden of proving that the use of the required safety equipment was reasonable or appropriate at Allstate’s worksite, relying on Spancrete Northeast, I&. V. OSHRC, 905 F.2d 589 (2nd Cir. 1990). The case cited by Allstate, however, does not reflect the state of the law of either the Ninth Circuit, where this
case is situated, or of the Commission
itself.
- $1926.502( 1) Built-uproofing--a weather-proofing cover, applied over roof decks, consisting of either a liquid-applied system, a single-ply system, or a multiple-ply system. Liquid-applied systems generally consist of silicone rubber, plastics, or similar material applied by spray or roller equipment. Single-ply systems generally consist of a single layer of synthetic rubber, plastic, or similar material and a layer or adhesive. . ..
II .
In order to make out the affirmative defense of infeasibility, Allstate must show that none of the abatement measures specified in subsection 500(g) were feasible at Allstate’s Billings worksite. The Commission has held that:
Employers must alter their customary work practices to the extent that alterations are reasonably necessary to accommodate the abatement measures specified by OSHA standards. . .. [However,] an abatement measure must be useable, during employees’ activities, for its intended purpose of protecting employees. If there is no way to use a measure for its intended purpose without unreasonably disrupting the work activities, the mere fact that the measure’s installation is physically possrble does not in our view mean that we should compel the employer to install the measure. Seibel Modem Mfg. & Welding Corp. supra at 1228, 39,685.
At the hearing, Allstate specifically stated that compliance with the cited standard was possible (Tr. 118, 192), although it introduced evidence that safety lines would become tangled and pull up the screws holding down the roof, increasing the time necessary to complete the job (Tr. 118, 135-36, 156, 192). No evidence regarding the feasibility of other motion-stopping systems, such as guardrails was introduced, nor did Allstate address the feasibility of a warning line system.
Allstate failed to show that the safety measures specified by the standard were
infeasible, and so to make out its affirmative defense.
III .
In addition, this judge rejects Allstate’s argument that its use of a verbal safety monitoring system as provided for under 5OO(g)(iii ) excuses its failure to use physical fall protection. The plain language of subsection (g)(iii) restricts the use of safety monitoring systems to roofs fifty feet or less in width, where mechanical equipment is not being used or stored. The plain language of (g)(iii) clearly does not provide for a safety monitoring system here, where the roof width was 120 feet3 and mechanical equipment was in use.
3 Simple rectangular roofs may not be subdivided. Appendix A to Subpart M for ~1926SOO(g)(l)--Roof Widths, serves as a guideline to subdividing irregularly shaped roofs. Its stated purpose is to “minimize the number of roof areas where ~1926SOO(g)(l)(iii) can be applied.”
5
The Commission has held that where a specifications standard does not provide for an alternative form of compliance, “the fact that the employer has implemented an alternative measure instead of the specified measure cannot, in itself, justify vacating a citation.” Secretary of Labor v. R & R Builders, Inc., 15 BNA OSHC 1383,199l CCH OSHD ll (No. 88-282, 1991).
IV .
Allstate argues that its alternative measures, though not in technical compliance with the standard, provide equal protection from the fall hazard, and that the violation should properly be classified as de minimik Allstate cites Phoenix RooFtg, Inc. v. Dole, 874 F.2d 1027 (5th Cir. 1989), a case involving the same standard in which the Fifth Circuit found “no
significant difference between the protection provided by the employer and that which would be afforded by technical compliance with the standard.” Id at 1032.
The facts of the case at bar, while similar to those addressed in Phoenix Roofing, do
not compel the result reached there. Here, the roof was too large for the single monitor, Ludwig, to see all the employees at once (Tr. 83, 136; Exh. C-l, at 350). Ludwig admitted at hearing that he had to move around the roof to observe employees who were performing different tasks on different sections of the roof (Tr. 155). Additionally, the noise from the drills and compressor in use on the rooftop could have prevented Ludwig’s warnings from being heard or heeded.
A designation of de mirzimis is appropriate only where the absence of any direct nexus
between the employer’s noncompliance and employee safety and health renders an abatement order inappropriate. This judge finds that Allstate’s use of a safety monitoring system did not provide protection equal to that mandated by the standard, and appreciably diminished worker safety. The violation cited was not merely technical, and cannot be classified as de minimis.
V
Under Commission precedent, a violation is willful if “it was committed voluntarily
with either an intentional disregard for the requirements of the Act, or plain indifference to employee safety.” United States Steel Cop, 12 BNA OSHC 1692, 1703, 1986-87 CCH OSHD li27,517, po 35,675 (No. 79-1998, 1986).
On September 10, 1991 Allstate received a “serious” citation alleging violation of $1926.500(g) (Tr. 91; Exh. C-11). At that time CO Wolf advised the job superintendent, Mike Phillips, as to the requirements of $1926.500(g), specifically discussing safety belts, lanyards, and static lines as well as warning lines (Tr. 61-67). Stan Ludwig was the foreman on the job site (Tr. 91). On March 24, 1992, and June 2, 1992 Allstate received “repeat” citations for violations of the same standard (Tr. 94, Exh. C-12, C-14). Either Ludwig or Phillips were involved in each of the cited incidents (Tr. 96). Phillips executed all three settlement agreements (Tr. Exh. C-12, C-14). At the hearing, Allstate admitted it knew the requirements of 51926.500(g) prior to the inspection (Tr. 93).
Nonetheless,
,
despite three previous citations, and their admitted familiarity with
$1926.500(g), Allstate personnel went on to uniformly testify that they believed the abatement measures discussed with OSHA applied only to the specific roof& they were working on at the time they were cited, and that the cited standard allowed them complete latitude to determine the “appropriate” fall protection to be provided. (Testimony of Wilbur Phillips, Tr. 115-116; 122; Stanley Ludwig, Tr. 164-165, Michael Phillips, Tr. M-93).
This judge finds such testimony unconvincing. Although a violation is not willful if
the employer had a good faith opinion that it complied with the requirements of a cited standard, the test of good faith for these purposes is an objective one, i.e. whether the employer’s belief concerning the interpretation of a standard, was reasonable under the circumstances. Calang Cop., 14 BNA OSHC 1789, 1791, 1987-90 CCH OSHD ll29,080, p. 38,870 (No. 85-319, 1990).
The plain language of §1926.5OO(g)(1) is unambiguous; the constraints on the options
available to an employer are clearly set forth in the standard. Allstate’s supervisory personnel, particularly its safety director, had a duty as well as ample opportunity to read and understand 5OO(g)‘srequirements following each of the three prior citations issued since September 1991. Given Allstate’s citation history, its settlements, and the explanation of 500(g) provided by OSHA officials, Allstate’s litigation position that it believed it had complete latitude to substitute its own judgment for the requirements of the standard is not
7 credible. Given its knowledge of $1926.500(g), and its knowledge of the ground to cave height, which triggered the standard’s applicability at this particular worksite, Allstate’s decision to substitute its own safety procedures for those required by the standard indicates a disregard for the Act’s requirements rising to the level of willfulness.
VI .
The size of the employer and the gravity of the offense are factors to be considered in determining the appropriateness of a penalty. Nacirema Operating CO., 1 BNA OSHC 1001, (No. 4, 1972).
One indicia of a company’s size is the amount of business it does.
Allstate’s gross
income during 1991 and 1992 was estimated at between two and three million dollars (Tr. 133) .
CO Wolf testified, without contradiction, that a fall from 20 feet would result in serious injury or death (Tr. 60). However, Allstate’s roofing personnel were experienced and the fall hazard was an obvious one. Weather conditions were good and there were no tripping hazards visible. The likelihood of an accident taking place was small; this judge believes that the gravity of the violation was overstated.
Because the gravity of the violation was overstated, the proposed penalty of $28,000.00 is found to be excessive. A penalty of $12,000.00 will be assessed.
Findings of Fact and Conclusions of Law
All findings of fact and conclusions of law relevant and necessary to a determination of the contested issues have been found specially and appear in the decision above.
See Rule 52(a) of the Federal Ru!es of Civil Procedure.
Order
- Citation 1, item 1 is d a penalty of $12,000.00 is
ASSESSED.
Dated: December 3, 1993 I