Trinity Solar, LLC, as successor to Trinity Solar, Inc.
Head and fall protection penalties reduced
Apply this to your situation
This order from 2024 bound only the parties to this case; it isn't precedent. Ezel answers your situation under the current OSHA standards and Commission precedent, with citations.
Plain-English summary
Trinity Solar employees installed solar panels on a residence in Yonkers, New York. OSHA cited a serious head-protection violation for work below solar installers and a repeat fall-protection violation for roof work 25 feet above the ground, proposing $98,216 in total penalties. Trinity withdrew its contest to liability and challenged only the penalty amounts. The judge upheld OSHA's gravity, size, history, and repeat assessments but found Trinity deserved a limited good-faith reduction for its safety program, onsite audits, cooperation, and acceptance of liability. The serious item was assessed at $11,050 and the repeat item at $77,344, reducing the total penalty to $88,394.
Decision snapshot
- Cited standard(s): 29 C.F.R. §§ 1926.100(a), 1926.501(b)(13)
- Outcome: Both violations affirmed; total penalties reduced from $98,216 to $88,394.
- Key point: A safety program with onsite auditing can support limited penalty credit, even when inconsistent discipline prevents a larger good-faith reduction.
Full text (OSHRC public release)
United States of America
OCCUPATIONAL SAFETY AND HEALTH REVIEW COMMISSION
1120 20th Street, N.W., Ninth Floor
Washington, DC 20036-3457
SECRETARY OF LABOR,
Complainant,
v. OSHRC DOCKET NO. 23-0666
TRINITY SOLAR, LLC as successor to
TRINITY SOLAR, INC.,
Respondent.
APPEARANCES:
Jordan Laris Cohen, Esq.
U.S. Dept. of Labor, Office of the Solicitor
New York, New York
For the Secretary
Richard B. Stone, Esq.
General Counsel, Trinity Solar, LLC
Joshua S. Fischer, Esq.
Associate General Counsel, Trinity Solar, LLC
For Respondent
BEFORE:
Covette Rooney
Chief Administrative Law Judge
DECISION AND ORDER
This proceeding is before the Occupational Safety and Health Review Commission (the
Commission) pursuant to § 10(c) of the Occupational Safety and Health Act of 1970, 29 U.S.C.
§ 659(c) (the Act).
Background
On November 23, 2022, employees of Trinity Solar LLC, as successor to Trinity Solar Inc.
(Trinity or Respondent) installed solar panels on a residence at 44 Kimball Terrace, Yonkers, New
York (Worksite or Kimball Terrace worksite). An Occupational Safety and Health Administration
(OSHA) compliance officer inspected the Worksite that day. Pursuant to the inspection, OSHA
issued a Citation and Notification of Penalty on April 13, 2023 (Citation). The Citation alleged two
violations of OSHA’s construction standard: one serious violation of 29 C.F.R .§ 1926.100(a) for
lack of head protection while working below solar panel installers, and one repeat violation of 29
C.F.R. § 1926.501(b)(13) for working on a roof 25 feet above ground without fall protection. The
Citation included a total penalty of $98,216 for the two violations. Respondent filed a timely Notice
of Contest (NOC) on April 25, 2023
The initial Complaint was filed by the Secretary on May 23, 2023. 1 Respondent filed its
Answer on May 31, 2023.
On November 21, 2023, Respondent filed an unopposed Notice of Partial Withdrawal of
Notice of Contest (Withdrawal of NOC) in which Respondent withdrew its NOC with respect to all
aspects of the alleged violations, except the proposed penalty amount. As set forth in the
undersigned’s November 22, 2023 Order, the only remaining issue to be litigated at the hearing
would be the reasonableness of the Citation’s proposed penalties.
On November 27, 2023, the undersigned granted Secretary’s Unopposed Motion to Amend
Citation and Complaint to correct the Respondent’s captioned name. 2
1
On November 27, 2023, the Secretary filed the amended Complaint, which in addition to correcting the
captioned name of the Respondent, also modified the violation description for Citation 1, Item 1 to insert the
designation of the regulation, “29 CFR § 1926.100(a),” that was inadvertently omitted in the original citation.
The Citation was not changed in any other respect. Respondent did not file an amended Answer.
2
The Respondent had been previously captioned as “Trinity Heating & Air, Inc., dba Trinity Solar.” Also,
see Stipulation 1 set forth below.
-2-
On January 17, 2024, a one-day hearing was held. Four witnesses testified: Austin Tyler,
Crew Leader for Trinity; Peter West, Assistant Area Director, OSHA; Kenneth Rucki, Director of
Safety for Trinity, and William Condit, Executive Vice-President of Trinity.
Issue
The sole issue in dispute is the amount of penalty to be assessed for the two citation items.
Respondent stipulated to liability for the cited violations in its Withdrawal of NOC. Respondent
offers arguments regarding the Secretary’s penalty adjustments for gravity, history, and, especially,
good faith. Respondent asks the undersigned to lower the $98,216 total penalty to $20,000. (R.
Br. 20).
For the reasons set forth below, the undersigned agrees with the Secretary’s penalty
assessments with respect to history, gravity, and size. With respect to good faith, the undersigned
finds a small penalty adjustment is merited and assesses a total penalty of $88,394.
Jurisdiction
Based upon the record, the undersigned finds Respondent, at all relevant times, was engaged
in a business affecting commerce and was an employer within the meaning of sections 3(3) and
3(5) of the Act, 29 U.S.C. §§ 652(3) and (5). (Stips. 1, 2, 7). The undersigned further finds the
Commission has jurisdiction over the parties and subject matter in this case.
Stipulations
In their Joint Pre-Hearing Statement, the parties stipulated to the following:
a. The respondent, Trinity Solar, LLC as successor to Trinity Solar, Inc., a limited
liability company organized under laws of the State of New Jersey and doing
business in the State of New Jersey, maintaining its principal office and place of
business at 2211 Allenwood Road, Wall, New Jersey 07719, is and at all times
hereinafter mentioned was engaged in solar panel installation. (Stip. 1).
b. Many of the materials and supplies used by Respondent originated and/or were
shipped from outside the State of New Jersey. (Stip. 2).
c. The current employee headcount for Trinity Solar, across all offices and
territories, is 3,041. (Stip. 3).
d. For the year 2022, Trinity received in excess of $10 million dollars in revenue.
(Stip. 4).
-3-
e. The pitch of the residential roof at the Trinity job site relevant to this matter was
34 degrees. (Stip. 5).
f. The Respondent is and at all times relevant was engaged in solar panel
installation work. (Stip. 6).
g. Respondent was and is engaged in a business affecting commerce within the
meaning of sections 3(3) and 3(5) of the Act and is an employer within the
meaning of section 3(5) of the Act. (Stip. 7).
h. Respondent is liable for Citation 1, Item 1, as issued, by virtue of Respondent’s
partial withdrawal of notice of contest and the Court’s resulting order of
November 22, 2023. (Stip. 8).
i. Respondent is liable for Citation 2, Item 1, as issued, by virtue of Respondent’s
partial withdrawal of notice of contest and the Court’s resulting order of
November 22, 2023. (Stip. 9).
j. The only question of law to be decided by this court in this matter is whether the
penalty proposed by OSHA is reasonable and commensurate under Section 17
of the Act, taking into account: (1) the size of the business of the employer being
charged, (2) the gravity of the violation, (3) the good faith of the employer, and
(4) the employer's history of previous violations. (Stip. 10).
(Joint Pre-Hearing Statement, 7-8).
Findings Of Fact
The Company
William Condit is the Executive Vice-President for Trinity and has worked for the company
since it was incorporated in 1994. (Tr. 216). Kenneth Rucki is the Director of Safety and has
worked for Trinity for 30 years. (Tr. 158-59). Mr. Rucki reports directly to Mr. Condit. (Tr. 192).
In its early years Trinity was an HVAC company with about 10 employees; in 2004 it
expanded into the installation of residential solar panels, growing to over 3,000 employees. (Tr.
176-77, 218; Stip. 3). In a typical month, across the entire company, between 1,000 and 1,600 solar
roof systems are installed. (Tr. 219). Thus, on any given day there are roughly 500-700 installers
at work. (Tr. 219). Trinity has multiple locations throughout the northeast, including Pennsylvania,
New Jersey, New York, Connecticut, and Massachusetts. (Tr. 179, 182).
At the time of the inspection, Austin Tyler was a Crew Leader for Trinity. (Tr. 27, 35). He
had worked for Trinity for about three years. (Tr. 27-28). As a Crew Leader, an employee gets a
promotion with increased compensation, a company vehicle, a company phone, and additional
-4-
vacation days. (Tr. 196). Mr. Tyler had been a Crew Leader at about 10 worksites and before that,
a crew member for more than 50 installations. (Tr. 27-28). A Crew Leader is in control of the
worksite with the crew reporting to him and is also responsible for assigning tasks and ensuring
safety rules are followed. (Tr. 28-29).
Worksite and Inspection
On November 23, 2022, Austin Tyler was the Crew Leader for Trinity at the Kimball
Terrace worksite. (Tr. 27, 35). Including Mr. Tyler, there were seven employees on the crew that
day. (Tr. 41-42). The day started at the warehouse at 6:30 a.m., where they loaded the truck with
the solar panels and brackets, and then drove to the Kimball Terrace worksite, which was at least
an hour away. (Tr. 39-40).
The Kimball Terrace job entailed the installation of 12 solar panels on the roof of a two-
story residence. (Tr. 35, 56; CX-2; CX-3; CX-4). The roof’s pitch was 34 degrees. (Stip. 5). Three
members of the crew worked primarily from the roof’s surface; the other three crew members and
Mr. Tyler worked from the ground. (Tr. 42-43). At times during the workday, Mr. Tyler worked
in the home’s basement on electrical tasks. (Tr. 57).
At the beginning of the workday, all employees wore personal fall arrest harnesses. (Tr.
48). At some point, the three assigned to work from the ground took off their personal fall arrest
harnesses. (Tr. 48). When Mr. Tyler saw the three ground crew members passing the solar panels
up to the roof, prior to the CO’s arrival, they were not wearing a harness nor a hardhat. (Tr. 48).
The installation of a solar panel includes preparing the roof by prying shingles, setting the
feet for rails, laying the panel’s rails, and installing the wiring. (Tr. 43). Tools used in this work
included pry bars, hammers, and impact drills. (Tr. 43). The installation of the solar panels onto
the roof began roughly halfway through the workday, after lunch. (Tr. 44).
Ladders were used to access the roof from the ground. (Tr 37; CX-3, p. 3). Each solar panel
was carried up the ladder by a member of the ground crew and then passed to the worker on the
roof. (Tr. 48, 55). Each solar panel weighed about 48 pounds. (Tr. 30). The three ground crew
members took turns taking the panels up the ladder to the roof. (Tr. 48). Generally, once at the
-5-
roof level, roof crew member, Mr. Rivera, took the roof panel and then passed the panel to another
roof crew member, Mr. Predmore, to carry the panel over the roof’s peak to be installed on the other
side. (Tr. 48-49, 54; Ex. C-3, pp. 5, 10-12). While the panels were being passed up from the
ground, Mr. Tyler was often working in the home’s basement with the electrical panel. (Tr. 57)
Respondent’s safety rules include the requirement to wear a hardhat when there is a danger
of falling objects and to use fall protection while on a roof. (Tr. 29-30). Mr. Tyler was aware of
times when an employee had slipped on the roof at other worksites. (Tr. 30-31). Mr. Tyler had
seen items such as screws, drills or other hand tools fall off the roof. (Tr. 30). Mr. Tyler admitted
that the hardhats had not been removed from the truck prior to the CO’s arrival, so the ground crew
had been working all day without head protection as the roof crew worked above them. (Tr. 58-
60).
The type of fall protection Respondent uses when installing solar panels is related to the
roof’s pitch. (Tr. 32, 95-97). If the pitch is greater than “26” a Y-strap configuration with a fixed-
length rope that attaches at the front of the harness is used. (Tr. 31, 95-97). If the pitch is lesser,
then a “shock pack”—a fall arrest system that attaches to the back, which decelerates and then stops
the fall—is used. (Tr. 94-95).
OSHA’s CO took photographs in the afternoon, when the crew had been working on the
roof for a while. (Tr. 47). The photographs show three employees on the roof, two wearing fall
arrest harnesses and the third employee not wearing a harness. (Tr. 52-53). The third employee in
the photo was one of the ground crew, Mr. Cesar. (Tr. 53). The CO photographed Mr. Cesar carry
a solar panel up the ladder, step up onto the roof, carry the panel to the roof’s peak, and then walk
back down the roof to the ladder. (Tr. 53-55, 58; CX-3, pp. 5-7, 10-11).
Mr. Cesar was not wearing a fall arrest harness nor using any other means of fall protection.
(Tr. 53-55; CX-3, p. 5). Roof crew members Mr. Predmore and Mr. Rivera wore fall arrest
harnesses but were not consistently tied off. (Tr. 59-60; CX-3, pp. 1-6, 9). Photographs show that
roof crew member, Mr. Rivera, was not attached to an anchor point. (Tr. 52-53; CX-3, pp. 2-3).
-6-
Mr. Tyler could not recall when he had last walked around the house, to verify that everyone
on the roof was using fall protection, prior to the CO’s arrival. (Tr. 56-59). Mr. Tyler admitted the
photographs show employees on the roof without the use of fall protection and employees on the
ground working without hardhats. (Tr. 60).
Safety Program
Trinity had a safety program that included a written safety manual, training, onsite audits,
and a disciplinary policy. 3 (Tr. 180, 189; RX-1 through RX-6; RX-18A, RX-18D). Respondent
provided safety equipment stored on its trucks. (Tr. 40, 198, 224). This included special ladders
that might be used to move a panel to roof; either by a panel lift rail system or a panel grab system—
there is no evidence these were used at the Kimball Terrace worksite. (Tr. 198).
Work Rules and Training
As a part of orientation, employees receive the company’s safety manual, which includes
the topics of job hazard analysis, fire protection, first aid, bloodborne pathogens, personal protective
equipment, hearing conservation, hand and power tools, lockout/tagout, ladders, fall protection,
trenching, heavy equipment, driver safety, and forklifts. 4 (Tr. 189, 203; RX-1; RX-18D, pp. 2-3).
A two-page pamphlet is also provided during orientation. (Tr. 197-98; RX-18A). This pamphlet
summarizes safety rules for employees that work in the office and in the field. (RX-18A). The
pamphlet sets forth basic safety rules with respect to office ergonomics, fall protection, hardhats,
ladder safety, arc-fault gloves, driver safety, lifting techniques, and site cleaning. (RX-18A).
Employees are provided training during orientation through videos, PowerPoint
presentations, and quizzes. (Tr. 62, 83, 92, 189; RX-1; RX-1D; RX-5; RX-18D). A 49-page slide
3
Respondent received recognition certificates for participating in the “Safe & Sound Week” in 2017 and
2018 (Tr. 203-04; RX-19D) and in the OSHA 2017 “National Safety Stand Down to Prevent Falls” at two
Trinity locations. (Tr. 199, 203; RX-18C; RX-19A). The certificates were related to safety videos that
Respondent had submitted to OSHA. (Tr. 199).
4
Instead of the entire safety manual, this exhibit includes just the manual’s cover page and table of contents.
(RX-18D, pp. 2-3). The manual is dated 9/30/14 and noted as provided by Safety Service Company. Id. In
a separate exhibit, a 6-page section of the safety manual entitled, “Company Policy Statement and Program
Components” sets forth an overview of the company’s safety philosophy. (RX-1A; Tr. 77-78).
-7-
presentation on fall protection is included in orientation training. (Tr. 98, 203; RX-18D). A quiz
is used to verify that the fall protection training has been understood. (Tr. 191; RX-1D).
Additionally, fall protection training is generally refreshed once per quarter with all employees.
(Tr. 89, 192; RX-4). Respondent’s safety rules require employees to wear a hardhat when someone
is working on the roof overhead and to be securely anchored with fall arrest equipment when
working on a pitched roof. (CX-5; RX-1B).
The safety policy includes consequences for not following work rules. It states that a first
offense results in a mandatory 3-day unpaid suspension and that a second offense results in
mandatory employment termination. (Tr.190; CX-5; RX-1B). After the first safety offense, an
employee is generally retrained and takes another quiz to ensure the training is understood. (Tr.
192). Mr. Tyler confirmed that the safety training he received at orientation included the
information that suspension or termination could result from not complying with the safety policy.
(Tr. 63, 75-79, 97-98, 106-07; RX-18D).
Audit Program
Trinity’s safety program includes onsite safety observations that are documented on a Job-
Site Safety Observation Form (audit form). (Tr. 162-63; CX-8). The safety officer in each region
randomly conducts site safety observations at worksites to evaluate compliance with its safety
requirements. (Tr. 161-63, 183, 208; CX-8). When a safety infraction is observed, work is stopped
and a correction is requested. (Tr. 208-10). The local manager is also notified. (Tr. 183-84, 208-
09). That manager then determines the nature of any disciplinary action that will be implemented.
(Tr. 183-84). The safety department has no role in determining whether an employee will be
disciplined or the nature of that discipline. (Tr. 184). Their role is to audit the worksites, document
any violations, and obtain immediate compliance. (Tr. 162-63, 208-09). Mr. Rucki discusses the
audits’ safety infractions with Mr. Condit. (Tr. 192-93).
Safety Committee
Respondent’s safety committee meets monthly and includes Mr. Rucki, a legal team
representative, the safety coordinators from all regional offices, the regional vice presidents, and
-8-
other departments’ representatives. (Tr. 221-24). Mr. Condit is the liaison between the safety
committee and the executive team. (Tr. 221). Mr. Rucki leads the meeting during which the
committee reviews the results of the prior month’s safety audits. (Tr. 223). Additionally, both
recordable and non-recordable injuries for the prior month are reviewed. (Tr. 223). The importance
of fall protection is discussed at this meeting. (Tr. 223-24). When the committee noted an increase
in violations of the hardhat policy, they changed the company’s work rule, in November 2022, to
require hardhats to always be worn, not just when there was an overhead hazard. (Tr. 225, 231)
Disciplinary Policy
Respondent’s safety policy states that a first offense results in a mandatory 3-day unpaid
suspension and that a second offense results in mandatory termination of employment. (Tr. 113,
190; CX-5; RX-1B). Crew leaders are notified when one of their crew members are disciplined.
(Tr. 108).
However, Mr. Rucki admitted there was a time, between March 2020 and December 2022,
when Trinity did not follow its disciplinary policy. (Tr. 190). Mr. Rucki questioned why there
were repeat offenders in the safety audits. (Tr. 190). He found that discipline was not being
implemented because Respondent thought it contributed to difficulty in hiring or retaining workers.
(Tr. 190-91).
Discipline related to the November 23, 2022 Kimball Terrace worksite
After OSHA inspected the Kimball Terrace worksite, Trinity conducted an internal review
and issued Mr. Tyler, as the worksite’s Crew Leader, a Memorandum of Conversation (MOC) for
not “monitoring the safety of the work site.” 5 (Tr. 79-80, 91, 195; RX-6). Mr. Tyler was required
to go through refresher training and lost his position as Crew Leader. (Tr. 79-82, 195-97). Mr.
Tyler was not eligible for promotion for a significant time thereafter. (Tr. 196). Further, the entire
crew from the Worksite was required to take refresher training and the related quizzes. (Tr. 92,
5
The MOC is dated January 27, 2023, and signed by Mr. Tyler and Bryan Traver, Manager. The description
states: “Receiving MOC for worksite that OSHA inspector showed up to on 11//23/22. Report stated not
monitoring the safety of the work site with reported issues of individual on roof unharnessed and lack of
head protection on two ground workers.” (RX-6).
-9-
197). No one from the Kimball Terrace crew received further discipline, such as a suspension. (Tr.
108-11).
Evidence of lax application of disciplinary policy
A sample of Respondent’s documented safety audits was submitted into evidence. (CX-8).
These audits show certain individuals failed to follow the company’s safety policy at multiple
worksites. Other than the discipline for the crew at the Kimball Terrace worksite, Respondent
provided no evidence of any discipline that had been implemented at previous worksites where the
audits revealed safety rule violations.
For example, Tom Diubaldo was in violation of safety rules at multiple worksites. At an
October 21, 2021 worksite, Trinity’s safety auditor documented that Crew Leader Tom Diubaldo
was working on the roof without being attached and was not properly wearing a fall protection
harness. (Tr. 171-72; CX-8, p. 111). The audit form noted that when told to make a correction,
Mr. Diubaldo responded by partially correcting his harness but continued to work without being
attached. Id. For a December 8, 2020 worksite, the auditor noted that the same Crew Leader, Mr.
Diubaldo, wore a harness but was not attached to a rope. (CX-8, p. 129). The December 8 audit
form notes that Mr. Diubaldo was advised that he should never work without being attached to a
rope anchored to the roof. Id. The form also noted that a formal disciplinary action would be
written and shared with the manager. Id. There is no evidence in the record that the recommended
disciplinary action was implemented. In addition, Mr. Diubaldo, either as Crew Leader or
individually, was not following fall protection safety rules at worksites on the following dates:
August 6, 2019 (CX-8, p. 142); December 11, 2020 (CX-8, p. 132); December 14, 2020 (CX-8, p.
127); May 18, 2021 (CX-8, p. 123); October 27, 2021 (CX-8, p. 109); August 2, 2022 (CX-8, pp.
85-86); August 12, 2022 (CX-8, pp. 83-84); and August 29, 2022 (CX-8, pp. 87-88). (Tr. 168-75).
As of July 2023, Mr. Diubaldo still worked for Trinity. (Tr. 175).
In September 2022, just three months before the Kimball Terrace inspection, a Trinity safety
auditor found Mr. Tyler’s crew working without any installed fall protection. (Tr. 110). No one
was terminated as a result and Mr. Tyler could not recall if anyone had been suspended because of
- 10 -
the September 2022 audit. (Tr. 111). Mr. Tyler stated that Trinity’s disciplinary policy was not
enforced as written, it was enforced on a case-by-case basis depending on severity—he believed
there was a three-strike rule. (Tr. 109, 113).
Cited Violations
To establish a violation of an OSHA standard, the Secretary must prove: (1) the cited
standard applies; (2) the terms of the standard were violated; (3) one or more employees had access
to the cited condition; and (4) the employer knew, or with the exercise of reasonable diligence could
have known, of the violative condition. Astra Pharm. Prods., 9 BNA OSHC 2126, 2129 (No. 78-
6247, 1981), aff’d in relevant part, 681 F.2d 69 (1st Cir. 1982) (Astra). Knowledge may be imputed
to the employer “through its supervisory employee.” Access Equip. Sys., Inc., 18 BNA OSHC
1718, 1726 (No. 95-1449, 1999). The Secretary has the burden of proving its case by a
preponderance of the evidence. Astra, 9 BNA OSHC at 2129.
Citation 1, Item 1
Respondent was cited for a serious violation of 29 C.F.R. § 1926.100(a), which states:
(a) Employees working in areas where there is a possible danger of head injury
from impact, or from falling or flying objects, or from electrical shock and burns,
shall be protected by protective helmets.
The parties have stipulated that “Respondent is liable for Citation 1, Item 1, as issued, by
virtue of Respondent’s partial withdrawal of notice of contest and the Court’s resulting order of
November 22, 2023.” (Stip. 8). The undersigned sets forth the undisputed facts that support the
prima facie elements for a violation of 29 C.F.R. § 1926.100(a).
Applicability, exposure, non-compliance, and employer knowledge are established.
Three employees worked on the ground below as their co-workers installed solar panels on
the roof. (Tr. 57-60; CX-8, p.14). They were exposed to injury from falling items, such as, solar
panels and tools. Hardhats were available at the Worksite. (Tr. 58-60). Mr. Tyler admitted the
hardhats had not been worn by anyone at the worksite prior to the CO’s arrival. (Tr. 58-60). Mr.
Tyler knew the employees were not wearing hardhats and knew it was company policy that
- 11 -
employees working on the ground were required to wear a hardhat as protection from objects falling
from the roof overhead. (Tr. 29, 58-60). Thus, applicability, exposure, non-compliance, and
employer knowledge are established.
Serious classification
Additionally, the Secretary classified this violation as serious. The Act states that “a serious
violation shall be deemed to exist in a place of employment if there is a substantial probability that
death or serious physical harm could result from” the violative condition. Section 17(k) of the Act;
29 U.S.C. § 666(k).
A serious characterization is appropriate when “a serious injury is the likely result should
an accident occur.” Pete Miller, Inc., 19 BNA OSHC 1257, 1258 (No. 99-0947, 2000). Here, falling
tools and solar panels could result in serious head injury. (Tr. 125).
Citation 1, Item 1 is affirmed as a serious violation. The assessed penalty is discussed
below.
Citation 2, Item 1
Respondent was cited for a repeat violation of 29 CFR § 1926.501(b)(13):
(13) Residential construction. Each employee engaged in residential construction
activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail
systems, safety net system, or personal fall arrest system unless another provision
in paragraph (b) of this section provides for an alternative fall protection measure.
The parties have stipulated that “Respondent is liable for Citation 2, Item 1, as issued, by
virtue of Respondent’s partial withdrawal of notice of contest and the Court’s resulting order of
November 22, 2023.” (Stip. 9). The undersigned sets forth the undisputed facts that support the
prima facie elements for a violation of 29 C.F.R. § 1926.501(b)(13).
Applicability, exposure, non-compliance, and employer knowledge are established.
Three crew members were assigned to work from the roof of a two-story residence. The
roof was about 25 feet above the ground and had a 34-degree pitch. (Tr. 139; Stip. 5). In addition
to the three crew members assigned to work on the roof, one of the ground crew, Mr. Cesar,
traversed the roof while carrying a 48-pound solar panel without the use of fall protection.
- 12 -
Photographs show two roof crew members wearing fall arrest harnesses; however, at least one
member, Mr. Rivera, was not attached to an anchor point at all times. Respondent’s onsite Crew
Leader knew that ground crew member Mr. Cesar had removed his fall arrest harness earlier that
day. Further, Mr. Cesar was in plain view when he was traversing the roof without fall protection. 6
Thus, applicability, exposure, non-compliance, and employer knowledge are established.
Repeat classification
Citation 2, Item 1 was classified as a repeat violation of serious nature. A fall from 25 feet
above ground can result in broken bones or death, thus it is serious in nature. (Tr. 139). See
generally, Pete Miller, 19 BNA OSHC at 1258 (15-foot fall would likely result in serious injury).
A violation may be deemed repeated “if, at the time of the alleged repeated violation, there was a
Commission final order against the same employer for a substantially similar violation.” Potlatch
Corp., 7 BNA OSHC 1061, 1063 (No. 16183, 1979). A prima facie showing of substantial
similarity is established by a final order of the Commission where the employer violated the same
standard. Id.; see also, Sec’y v. D.M. Sabia Co., 90 F.3d 854, 856 (3d Cir. 1996) (citing Potlatch).
The repeat citation issued here is based on a prior citation of 29 CFR § 1926.501(b)(13)
from OSHA inspection 1566572, which became a final order on August 8, 2022. (Tr. 125, 129;
CX-1, p. 9; CX-9, pp. 1-15). Because the prior citation was for the same standard that was violated
here, substantial similarity is established.
Even though Respondent withdrew its notice of contest with respect to the repeat
classification, it seems to argue that because the precedent violation was modified from serious to
other-than-serious during settlement negotiations, it cannot be considered substantially similar to
the current violation that is serious in nature. The undersigned rejects this argument. The basis for
6
See A.L. Baumgartner Constr., Inc., 16 BNA OSHC 1995, 1998 (No. 92-1022, 1994) (constructive
knowledge found where violative conditions in plain view); Automatic Sprinkler Corp. of America, 8 BNA
OSHC 1384, 1387 (No. 76-5089, 1980) (an employer “must make a reasonable effort to anticipate the
particular hazards to which its employees may be exposed” and give “instructions to prevent exposure to
unsafe conditions”).
- 13 -
determining the validity of the repeated characterization is not based on the gravity or classification
of the precedent violation. See Austin Road Co., 8 BNA OSHC 1916, 1918 (No. 79-1158, 1980)
(Commission finding that the determination of the precedent citation as nonserious did not preclude
a repeat classification for the serious violation at issue). Further, Respondent presented no evidence
there were disparate conditions between the current and precedent citation. Potlatch Corp., 7 BNA
OSHC at 1063 (employer may rebut prima facie showing of substantial similarity “by evidence of
the disparate conditions and hazards associated with these violations of the same standard”).
The undersigned finds the repeat classification of Citation 2, Item 1 is supported.
Penalty Determination
The penalty amount is the sole contested issue. Respondent asserts that it deserves a good
faith discount because it takes safety seriously and cooperated with OSHA during the inspection
process. (R. Br. 13-17). Respondent also asks the undersigned to modify the penalty adjustments
for gravity and history. (R. Br. 9-12).
OSHA’s penalty assessment
For Citation 1, Item 1, OSHA set forth a penalty of $12,278. The statutory maximum for a
serious citation was $15,625. 88 Fed. Reg. 2210, 2220 (Jan. 13, 2023). In calculating the penalty,
OSHA determined the gravity was moderate based upon the high severity of an injury from a falling
object (i.e., a falling 48-pound solar panel) with a lesser probability of occurrence. 7 (Tr. 124-25).
In assessing the company’s history, OSHA looked at five years of inspection history and assessed
a penalty increase based on two previous citations issued to Respondent. (Tr. 142-43). The first
was inspection 1402691, which became a final order on September 5, 2019, through an informal
settlement agreement. (CX-9, pp. 21-24). The second was inspection 1566572, which became a
7
OSHA uses their Field Operations Manual as a guide for the calculation of penalties. See Hackensack Steel
Corp., 20 BNA OSHC 1387, 1392 (No. 97-0755, 2003) (the FOM’s instructions “are only a guide for OSHA
personnel to promote efficiency and uniformity, are not binding on OSHA or the Commission, and do not
create any substantive rights for employers”)
- 14 -
final order on August 8, 2022, through a stipulated settlement agreement. (CX-9, pp. 1-15). OSHA
made no size adjustment as Respondent has over 3,000 employees. (Tr. 125, 142). OSHA provided
no discount for good faith due to Respondent’s prior citation history. (Tr. 131, 142-47).
With respect to Citation 2, Item 1, OSHA classified the violation as a repeat citation and
proposed a penalty of $85,938. The statutory maximum penalty for a repeat violation is
$156,259. 88 Fed. Reg. at 2220. The fall protection violation was determined to have high gravity
based on the severity of the injury from a 25-foot fall and a high probability because of the slope of
the roof, proximity of work to the edge, and the fact 12 heavy solar panels were handled throughout
the day. (Tr. 139, 147, 150, 153, 155). OSHA made no adjustment to the penalty for size. (Tr. 125,
142). There was no good faith adjustment due to the repeat nature of the violation. (Tr. 130-32,
147). OSHA assessed a penalty increase for the Respondent’s citation history, as discussed above.
(Tr. 142-43).
Commission is the final arbiter of penalties.
It is well-settled the Commission “is the final arbiter of penalties . . . .” Hern Iron Works,
Inc., 16 BNA OSHC 1619, 1624 (No. 88-1962, 1994); Valdak Corp., 17 BNA OSHC 1135, 1138
(No. 93-0239, 1995) (“The [OSH Act] places limits for penalty amounts but places no restrictions
on the Commission's authority to raise or lower penalties within those limits”), aff'd, 73 F.3d 1466
(8th Cir. 1996). Section 17(j) of the Act requires the Commission to give due consideration to four
criteria in assessing penalties: the size of the employer's business, the gravity of the violation, the
employer's good faith, and its prior history of violations. 29 U.S.C. 666(j). Gravity is generally the
primary factor in the penalty assessment. See J. A. Jones Constr. Co., 15 BNA OSHC 2201, 2214
(No. 87-2059, 1993) (J.A. Jones). An ALJ has the discretion to not provide a discount for good
faith or prior history based on the established evidence and may determine the violation’s gravity
merits the maximum penalty. See Bush & Burchett, Inc. v. Reich, 117 F.3d 932, 940 (6th Cir. 1997)
(citations omitted).
- 15 -
Employer size
There was no penalty adjustment for either citation item because a company with more than
250 employees does not qualify for a size reduction. (Tr. 125, 142). The undersigned finds it is
appropriate to not provide an adjustment to the penalty for a company of over 3,000 employees.
Gravity is the primary factor in penalty assessment.
“The gravity of a particular violation [] depends upon such matters as the number of
employees exposed, the duration of the exposure, the precautions taken against injury, and the
likelihood that any injury would result.” J. A. Jones, 15 BNA OSHC at 2214 (citations omitted).
With respect to the gravity for Citation 2, Item 1, 8 the fall protection violation, Respondent
asserts that a high gravity rating is not merited because the evidence showed that only one employee
was on the roof without fall protection and the other employees wore their personal fall arrest
harnesses. (R. Br. 9-10). Respondent also asserts that a high gravity rating is not merited because
of its “precautions against injury”—provision of training, onsite safety auditors, and equipment,
such as, hardhats and personal fall arrest systems. (R. Br. 12). The undersigned disagrees.
The two cases cited by Respondent do not support its position. First, Bandas Industries,
Inc., a decision by an administrative law judge of the Federal Mine Safety and Health Review
Commission (FMSHRC ALJ), addresses compliance requirements under the Federal Mine Safety
Act, which are not applicable to a violation of the OSH Act. See No. 198-100-M, 1986 WL 221693
(FMSHRC ALJ, Nov. 12, 1986) (decision approving settlement agreement). The second case,
Benise-Dowling, Inc., is a decision where the ALJ found the gravity was moderate because a single
employee was exposed once per month to a hazardous solution. 2011 WL 1496747, at *1 (No. 10-
0449, 2011) (ALJ). Here, the gravity of injury was high, in part, because the employee was walking
up a steep roof while carrying a 48-pound solar panel. The facts of Benise are not comparable to
the facts here and thus the case is not persuasive. Further, decisions of administrative law judges
8
Respondent does not assert an argument regarding the gravity of Citation 1, Item 1.
- 16 -
are not precedential. See Leone Constr. Co., 3 BNA OSHC 1979, 1981 (No. 4090, 1976)
(unreviewed portion of a judge's decision does not constitute precedent).
While Respondent’s “precautions against injury” are important components of a safety
program, they are to no avail if the employees do not utilize the equipment. The Crew Leader at
the Kendall Terrace worksite knew that Mr. Cesar had removed his fall protection harness early in
the day but took no action. (Tr. 48). The other employees on the roof wore their harnesses, but at
least one was not always attached. (Tr. 52-54; CX-3, pp. 2-4). Further, the Crew Leader admitted
that he couldn’t really observe whether the roof crew was attached when he was working close to
the home. (Tr. 69). Finally, carrying a 48-pound solar panel on a 34-degree pitch roof increases
the likelihood a fall could occur. See J. A. Jones, 15 BNA OSHC at 2214 (citations omitted)
(likelihood of injury affects gravity of violation).
Respondent asserts Mr. Cesar was only on the roof a short amount of time so he had minimal
fall exposure. (R. Br. 10-11). There is no evidence in the record of the length of time Mr. Cesar
was on the roof. Even so, for an evaluation of gravity, the duration of the exposure is considered
in the context of all other factors including likelihood of injury. See generally, Flint Eng'g &
Constr. Co., 15 BNA OSHC 2052, 2056 (No. 90–2873, 1992) (rejecting employer’s argument that
brief duration made hazard less serious). When considered with the pitch of the roof and the weight
of the solar panels, even a short exposure is of high gravity.
The undersigned finds a high gravity assessment for the fall protection violation is
appropriate.
Employer’s inspection history
OSHA reviewed five years of Respondent’s inspection history. A penalty increase for
history was applied based on two prior inspections. (Tr. 142-43). Respondent asserts two
arguments as to why it was not appropriate to increase its penalty for this prior citation history.
Respondent first asserts that since it had not been previously cited for a violation related to
head protection, the penalty should not have been increased for Citation 1, Item 1. Respondent’s
argument is rejected. For purposes of the penalty, the history adjustment is about the employer’s
- 17 -
prior citation history generally, not whether it was repeatedly cited for the same standard. Orion
Constr., Inc, 18 BNA OSHC 1867, 1868 (No. 98-2014, 1999) ("penalty factor encompasses all of
an employer's prior violations, not just those of the same standard") (emphasis in original).
Respondent also asserts that its prior citation history was too minimal to merit a penalty
increase. (R. Br. 18). In particular, the 2022 citation item that was changed to other-than-serious
during settlement negotiations should not be considered. (CX-9, p. 1). In support of the assertion
that its history should be considered minimal, Respondent cites to L&B Products Corp., No. 95-
1721, 1998 WL 99285, **7, 50 (OSHRCALJ, Feb. 27, 1998) (L&B) and In re: RJP Framing Inc.,
No. 13-R2D1-3729, 2015 WL 10058937 (Cal OSHA, June 30, 2015) (RJP). Respondent contends
these cases support its assertion that, when evaluating an employer’s inspection history, only prior
citations of a serious nature can be considered. Both cases relied upon are inapt.
In L&B, the judge simply stated there was no evidence of serious, willful, or repeat
violations in that employer’s history. L&B, 1998 WL 99285, at *50. There was no discussion in
that decision of whether an other-than-serious violation could be considered in the penalty
adjustment for history. Further, L&B is not a precedential Commission decision. 9
In RJP, California’s safety regulations—which state that a “good” history rating applies
when, in the prior three years, an employer had no serious, repeat or willful violations and less than
one regulatory violation per 100 employees—were relied upon by the judge. See RJP, 2015 WL
10058937, at *6, n.10. California’s safety regulations are not applicable here and there are no
comparable federal OSHA regulations that set forth a particular method to establish a penalty
adjustment based on an employer’s history.
Respondent also asserts that its citation history must be viewed as a percentage of all of its
worksites. However, Respondent cites no case law to support its assertion that the number of
worksites an employer operates in a year should be considered when evaluating its citation history.
9
Decisions of administrative law judges are not precedential. See Leone, 3 BNA OSHC at 1981 (unreviewed
part of judge's decision is not binding Commission precedent).
- 18 -
The undersigned finds that both prior citations can be considered to determine Respondent’s
overall citation history. Therefore, an increase in the penalty calculation for history is merited.
Good faith penalty factor
The Commission focuses on factors related to the employer’s actions, including the
employer’s safety and health program and its commitment to assure safe working conditions, to
determine whether an employer’s overall efforts to comply with the Act and to minimize harm from
any violation of the Act merit a good faith penalty discount. Monroe Drywall Constr., Inc., 24
BNA OSHC 1209, 1211 (No. 12-0379, 2013) (citations omitted); see also, Ed Taylor Constr. Co.,
15 BNA OSHC 1711, 1718 (No. 88-2463, 1992) (balancing “commendable measures” such as
establishing a safety program with the “clearly inadequate” implementation of the program in
denying good faith credit). 10
Respondent asserts that a good faith reduction to the assessed penalty is merited because its
safety program, commitment to job safety, cooperation during the OSHA inspection, and efforts to
minimize harm merit a significant reduction for good faith. 11 (R. Br. 13-17; R. Reply Br. 2).
Respondent asserts that the total penalty for both citation items should be $20,000, instead of
$98,216 set forth in the issued Citation. (R. Br. 20).
An employer’s written safety program is considered in the context of the employer’s general
approach to all safety matters and the program’s mitigation of harm. For example, the Commission
has not provided a good faith penalty reduction when the evidence shows an employer’s overall
attitude toward safety seems lax. See Jesco Inc., 24 BNA OSHC 1076, 1080 (No. 10-0265, 2013)
(finding that steps taken to lessen the probability of harm were insufficient to warrant a credit for
10
The Secretary cites several decisions of administrative law judges to support its argument for a good faith
penalty adjustment. While these cases can be informative, they are not Commission precedent. See Leone,
3 BNA OSHC at 1981 (unreviewed part of judge's decision is not binding Commission precedent).
11
Respondent relies heavily in its briefing on J.C. Stucco & Stone, Inc., 26 BNA OSHC 1382 (Nos. 14-
1558, 2016) (consolidated) for case law regarding penalty assessments. J.C. Stucco is a non-precedential
decision of an administrative law judge. See Leone, 3 BNA OSHC at 1981. The undersigned finds J.C.
Stucco informative to the extent that it relies on a significant number of precedential Commission decisions.
- 19 -
good faith); Burkes Mech., Inc., 21 BNA OSHC 2136, 2142 (No. 04-475, 2007) (no good faith
penalty reduction where superintendent failed to inspect bark pit and foreman had no knowledge of
LOTO procedures); Propellex Corp., 18 BNA OSHC 1677, 1685 (No. 96-0265, 1999) (“because
Propellex supervisory personnel tolerated and participated in the violations for several weeks and
because Propellex evinced a lax attitude toward the enforcement of safety rules and standards, we
do not believe that a reduction for good faith is appropriate”).
In other cases, an employer’s attempts toward safety and compliance—even when
imperfectly executed—have merited a good faith penalty reduction. See Aviation Constructors,
Inc., 18 BNA OSHC 1917, 1922-23 (No. 96-0593, 1999) (overall circumstances show the
employer’s intent to be compliant where it requested an engineer’s approval of the shoring plan,
even though it ultimately implemented a shoring plan that was not approved by a professional
engineer); V.I.P. Structures, Inc., 16 BNA OSHC 1873, 1875 (No. 91-1167, 1994) (Commission
allowed good faith penalty reduction where employer attempted to move safety nets into position).
Further, even where the Commission affirms a violation as repeated or willful, it may still
allow a penalty reduction for good faith. See Pentecost Contracting Corp., 17 BNA OSHC
1953, 1956 (No. 92-3788, 1997) (citation omitted) (“Although we have found that Pentecost has
not established sufficient good faith to negate a willful characterization, Pentecost's increased safety
efforts after the inspection, including the weekly safety meetings, are relevant indicators of good
faith for the purpose of penalty determination.”); Anderson Excavating & Wrecking Co., 17 BNA
OSHC 1890, 1894 (No. 92-3684, 1997), aff'd per curiam, 131 F.3d 1254 (8th Cir. 1997) (even
though violation was willful, employer’s efforts during the inspection demonstrated good faith for
penalty purposes); C.N. Flagg & Co., 2 BNA OSHC 1195, 1197 (No. 1734, 1974), aff'd, 538 F.2d
308 (2d Cir. 1976) (unpublished) (distinguishing the general good faith of an employer from the
willful actions of particular supervisors at the work site in question).
But in other instances, the Commission has declined to provide a penalty reduction where
the violation was repeated or willful in nature. See Centex-Rooney Constr. Co., 16 BNA OSHC
2127, 2130-31(No. 92-851, 1994) (fact that violations were repeated diminishes the effect of a good
- 20 -
safety program); see also, Elliot Constr. Corp., 23 BNA OSHC 2110, 2119 (No. 07-1578, 2012)
(even though employer cooperated during the inspection, its lax safety attitude and the willful nature
of violation negates any penalty reduction for good faith); Gen. Motors Corp., CPCG Okla. City
Plant, 22 BNA OSHC 1019, 1048 (No. 91-2834E, 2007) (consolidated) (no credit for good faith
when management tolerated and encouraged hazardous work practices related to willful
violations).
Therefore, to determine whether a good faith penalty reduction is merited here, the
Respondent’s safety program must be considered as a whole. The undersigned finds the
Commission’s decision in Compass Environmental Inc. instructive for evaluating the Respondent’s
safety measures. 23 BNA OSHC 1132, 1137 (No. 06-1036, 2010) (finding good faith penalty
reduction merited) aff’d, 663 F.3d 1164 (10th Cir. 2011) (Compass).
In Compass, a new employee working near an excavator on a construction site was fatally
electrocuted when the excavator’s boom contacted powerlines at the site. Compass, 23 BNA
OSHC at 1134. The employer had scheduled the removal of the powerlines at the worksite for
three days after the accident—the employer believed the excavator would not be in the area of the
powerlines before that time. Id. Even though the other employees at the site had received
powerline safety training, the new employee had not. Id. The employer was cited for a violation
of a training standard and the Commission found that the lack of training in powerline hazards was
directly related to the employee’s death. Id.
Despite the lack of training for this employee, the Commission found the employer had “an
extensive safety program including (1) a disciplinary program; (2) safety audits; (3) written safety
quizzes; (4) daily tailgate safety meetings; and (5) training for all of its other employees who
worked at the job site.” Compass, 23 BNA OSHC at 1137. The Commission also credited the
employer’s implementation of a new energy hazards training course after the accident. Id. Further,
the Commission found the employer’s plan to remove the powerline in anticipation of upcoming
work showed an intent to protect workers, even though it had not been removed soon enough. Id.
- 21 -
Despite the occurrence of a fatality, the Commission applied a good faith discount that reduced
the penalty from $6,300 to $5,500 (roughly 12%). Id.
In Compass, the Commission weighed the unsuccessful aspects of the employer’s safety
program with the employer’s efforts to significantly improve their safety program and provided a
discount despite the occurrence of the training-related fatality at the worksite. Here, while not fully
successful, Respondent had in place several components of an adequate safety policy. Of particular
note is the Respondent’s in-house auditing program that documents safety compliance at its
worksites. Nonetheless, despite having rules, training, and onsite audits in place, the Respondent
did not have an effective means to enforce compliance with its rules. The safety department carried
out its role in auditing the worksites, yet management did not consistently follow through with the
disciplinary consequences set forth in the company’s safety policy. Respondent acknowledged that
it did not follow its written disciplinary policy. The only evidence of discipline is the discipline of
Austin Tyler and retraining of the Kendall Terrace crew after the inspection.
In Compass, the Commission found that on balance a limited good faith reduction was
merited when all factors were considered. Compass, 23 BNA OSHC at 1137 (reducing penalty
from $6,300 to $5,500). Here, the Respondent’s repeat violation of the same fall protection standard
is balanced against their overall safety program. When viewed in its totality the Respondent has a
good safety program, and in particular, the use of the on-site auditors to improve workplace safety
compliance. However, the Respondent did not have a meaningful disciplinary policy to reinforce
its safety training. This lack of enforcement of its safety rules allowed employees to continue
violating the company’s safety policy even after an on-site auditor observed a violation. When
viewed as a whole, Respondent has made significant efforts toward its safety program, even if it
has not been fully implemented.
Because there was not a consistent application of consequences to employees who were
found in violation of Respondent’s safety rules despite the efforts of the onsite auditors,
Respondent’s program does not merit a large discount for good faith. It certainly does not merit a
reduction of the penalty by eighty percent as requested by the Respondent. (R. Br. 20). The
- 22 -
undersigned applies a ten percent good faith discount to the proposed penalty for the Respondent’s
attempts to implement an adequate safety policy, especially its onsite safety audits. The safety
program, when considered in concert with the Respondent’s generally cooperative attitude during
the inspection and its willingness to accept liability for the cited violations, supports a minimal good
faith discount. See Nacirema Operating Co., Inc., 1 BNA OSHC 1001, 1002 (No. 4, 1972) (“Good
faith should be determined by a review of the employer's own occupational safety and health
program, its commitment to the objective of assuring safe and healthful working conditions and its
cooperation with other persons and organizations” like OSHA.). Thus, the total penalties assessed
are reduced to $88,394.
Findings of Fact and Conclusions of Law
All findings of fact and conclusions of law relevant and necessary to a determination of the
contested issues have been made above. See Commission Rule 90(a). 29 C.F.R. § 2200.90(a). All
proposed findings of fact and conclusions of law inconsistent with this decision are denied.
ORDER
Based upon the foregoing findings of fact and conclusions of law, it is ORDERED that:
- Citation 1, Item 1, alleging a Serious violation of 29 C.F.R § 1926.100(a) is AFFIRMED and a
penalty of $11,050 is ASSESSED.
- Citation 2, Item 1, alleging a Repeat violation of 29 C.F.R. § 1926.501(b)(13) is AFFIRMED
and a penalty of $77,344 is ASSESSED.
_/s/Covette Rooney____
Covette Rooney
Chief Judge
Dated: May 24, 2024
Washington, D.C.
- 23 -
Get today's answer for your situation
You just read what one judge decided for one employer in 2024, and it binds only those parties. Ezel checks the current OSHA standards and Commission precedent and answers your specific situation, with citations.
Opens in Ezel Pro. Every answer cites the authority it relies on.