OSHRC ALJ decision Docket 10-2329 Decided November 14, 2011 Modified Judge Ken S. Welsch

Eutaw Construction Company, Inc.

Controlling-employer trench citation affirmed

Apply this to your situation

This order from 2011 bound only the parties to this case; it isn't precedent. Ezel answers your situation under the current OSHA standards and Commission precedent, with citations.

Currency note: this decision dates from 2011
The OSHA standards may have been amended, penalty amounts have been adjusted, and later Commission or court decisions may have changed the analysis since then. Treat this page as historical context, not current compliance advice. Verify the current standard before relying on any specific rule, threshold, or penalty mentioned here.
Final order, not Commission precedent
This decision by an OSHRC Administrative Law Judge became a final order of the Commission because no Commissioner directed review (29 U.S.C. § 661(j)). It binds the parties but is not binding precedent in other cases. The full text below is from the official OSHRC release.
About this page: The plain-English summary and decision snapshot below were written by Ezel based on the official OSHRC release. The full text is the Commission's own document.
Read the official release (oshrc.gov)

Plain-English summary

Eutaw Construction was the general contractor for a sewer-line project where a subcontractor worked in a 14-foot-deep bore pit. The excavation was dug in unstable Type C soil, and its protective system had trench boxes several feet above the bottom, gaps, a damaged support, water seepage, erosion, and fissures. Eutaw's superintendent knew the system was unsafe and had authority to stop and correct the work, but believed the subcontractor alone was responsible. The judge held Eutaw liable as the controlling employer and rejected its employee-misconduct and infeasibility defenses because it lacked effective multi-employer safety rules, monitoring, and discipline, and later lowered the trench boxes to abate the hazard. The serious violation was affirmed, with the proposed $7,000 penalty reduced to $2,500.

Decision snapshot

  • Cited standard(s): 29 C.F.R. § 1926.652(a)(1)
  • Outcome: The serious cave-in-protection citation was affirmed, and the proposed penalty was reduced from $7,000 to $2,500.
  • Key point: A controlling contractor with authority and knowledge cannot ignore a subcontractor's visible trench hazard merely because its own employees are not exposed.

Full text (OSHRC public release)

               UNITED STATES OF AMERICA
   OCCUPATIONAL SAFETY AND HEALTH REVIEW COMMISSION

Secretary of Labor,
Complainant
v. OSHRC Docket No. 10-2329
Eutaw Construction Company, Inc.,
Respondent.

Appearances:

      Uche N. Egemonye, Esquire, Office of the Solicitor, U.S. Department of Labor, Atlanta, Georgia
              For Complainant

      David C. Goff, Esquire, Deutsch, Kerrigan & Stiles, L.L.P., Gulfport, Mississippi
              For Respondent

Before: Administrative Law Judge Ken S. Welsch

                                      DECISION AND ORDER

      Eutaw Construction Co., Inc. (Eutaw) is a heavy construction and underground utility

contractor headquartered in Aberdeen, Mississippi. In December 2009, the City of Dothan,
Alabama, contracted Eutaw to install a 48-inch underground sewer line between two treatment
plants. To assist in laying the sewer line under a four lane highway, Eutaw subcontracted B & B
Underground Contractors, Inc. (B & B) to perform three boring operations.
After conducting a planned inspection of the project on October 5, 2010, the Occupational
Safety and Health Administration (OSHA) issued to Eutaw a serious citation on October 19, 2010.
The citation alleges Eutaw violated 29 C.F.R. § 1926.652(a)(1) by failing to ensure that B & B
provided adequate cave-in protection for employees working in an excavation, 14-feet in depth, used
to perform the boring operation. The serious citation proposes a penalty of $ 7,000.00. Eutaw timely
contested the citation.
The case was heard in Dothan, Alabama, on July 7, 2011. The parties stipulated jurisdiction
and coverage (Tr. 8). The parties filed post-hearing briefs.
Eutaw denies the violation and claims the standard was not violated because of a layer of
rock below the less stable Type C soil. Eutaw also argues that under the multi-employer worksite
doctrine, it was not responsible as a general contractor for the inadequate cave-in protective system
utilized by B & B. Eutaw’s employees were not working in the excavation. As affirmative defenses,
Eutaw asserts unpreventable employee misconduct as to its project superintendent and infeasibility
because of the layer of rock. (Tr. 12-13, 15).
For the reasons discussed, Eutaw’s arguments are rejected, and the citation is affirmed and a
penalty of $ 2,500 is assessed.
Background
Eutaw’s primary business involves heavy construction and the installation of underground
utilities. Eutaw employs approximately 300 employees. Its main office is located in Aberdeen,
Mississippi (Tr. 145).
In 2009, the City of Dothan, Alabama contracted Eutaw to install approximately 22,000 feet
of 48-inch diameter sewer line from the Little Choctawhatchee Treatment Plant to the Beaver Creek
Wastewater Treatment Plant. The project began in December 2009. In order to run the sewer line
underneath Highway 84 (a four lane highway), Eutaw contracted B & B to perform the boring
operation. The three borings by B & B were for a total of approximately 600 feet. Eutaw’s project
superintendent was James Allen (Tr. 114, 125-126, 148-149).
On October 5, 2010, OSHA Compliance Officer (CO) Dale Schneider initiated a planned
inspection of the project. His inspection involved B&B’s bore pit #3 which was on the south side of
the westbound lane of Highway 84. B & B had been at this bore pit for approximately two months.
At the time of the inspection, the bore pit was dug, the boring equipment was in the pit, and boring
operations under the highway were proceeding. CO Schneider interviewed B&B’s owner Oneal
Bates and Eutaw’s project superintendent Allen. Superintendent Allen acknowledged the excavation
used as the bore pit was unsafe, but he did not believe that it was Eutaw’s responsibility to correct
the condition (Exh. C-2; Tr. 21, 36, 47, 66, 80, 82, 143).
The bore pit was approximately 18 feet wide, 45 feet long and 14 feet deep. Two trench
boxes, set side by side, were in the excavation and steel sheeting placed behind them. The trench
boxes were 8 feet tall. The boxes were placed approximately four feet off the bottom of the
excavation and a gap of several inches was between the two trench boxes. There were also gaps in
many places between the boxes and the walls of the excavation. CO Schneider did not consider B &
B’s protective system adequate because the boxes were not within two feet of the bottom, one cross
member was bent, and one box was not level (Exh. C-1A through 1K; Tr. 23).
CO Schneider observed that the east and west walls of the excavation contained fissures,
erosion, and inadequate backfill behind the trench boxes. Also, water accumulations were seen in
the bottom of the excavation despite a pump in the northeast corner. CO Schneider saw water
seeping from the west wall in two locations which he testified could cause the wall to destabilize and
collapse (Tr. 23, 31-32). He opined that it was a “very unstable excavation trench wall” which could
“blowout at any time” (Tr. 59).
CO Schneider classified the soil in the excavation as Type C soil, based on his visual
observation and a manual penetration test (Tr. 55-56). The two soil samples collected from the spoil
pile and sent to OSHA’s Salt Lake City Laboratory for analysis confirmed the Type C soil
classification. The analysis described samples as greyish-brown granular sand, containing in excess
of 89% sand and gravel (Exhs. C-4, C-5; Tr. 104).
When CO Schneider returned on October 6, 2010, Eutaw had shut down the work in the
excavation. It had put caution tape around the bore pit. Eutaw began lowering the trench boxes to
within two feet of the bottom of the excavation, backfilled behind the boxes, and slopped the
excavation walls away from the top of the trench boxes (Tr. 60-61, 145).
As a result of CO Schneider’s inspection and observations, Eutaw received a serious citation
for violation of 29 C.F.R. § 1926.652(a)(1). 1
Discussion
The Secretary has the burden of proving a violation.
In order to establish a violation of an occupational safety or health
standard, the Secretary has the burden of proving: (a) the applicability
of the cited standard, (b) the employer’s noncompliance with the

1
As a result of the same OSHA inspection, B & B received serious and other than serious citations on January 21,
2011, alleging, among other violations, a similar violation of §1926.652(a)(1). B & B contested the citations and the
hearing was held May 10-11, 2011 in Abbeville, Alabama. Judge Calhoun’s Decision and Order, entered on June 27,
2011 (Docket No. 11-0466), affirmed most of the violations against B & B, including the serious violation of
§1926.651(a)(1). Judge Calhoun’s Decision was not directed for review by the Commission and has become a final
order.
standard’s terms, (c) employee access to the violative conditions, and
(d) the employer’s actual or constructive knowledge of the violation
(i.e., the employer either knew or, with the exercise of reasonable
diligence could have known, of the violative conditions).

Atlantic Battery Co., 16 BNA OSHC 2131, 2138 (No. 90-1747, 1994).

    Eutaw stipulates, as the general contractor, that it was the controlling employer of the B & B

excavation (Tr. 8). Eutaw does not dispute the condition of the protective system observed by CO
Schneider.
Violation of § 1926.652(a)(1)
The citation, as amended by Order dated June 26, 2011, alleges that “On or about October 5,
2010 and times prior at Hwy 84W and Green Valley Rd, Dothan, Al: The employer exposed
employees of B & B Underground Contracting, Inc. to cave-in hazards by not ensuring adequate
cave-in protection was provided in an excavation approximately 14 feet deep, 18 feet wide, and 48
feet long in that items such as but not limited to one of the trench shield supports was bent/damaged
and the trench boxes were not installed a maximum of 2 feet from the bottom of the trench.” Section
1926.652(a)(1) provides, in part:
Each employee in an excavation shall be protected from cave-ins by
an adequate protective system designed in accordance with paragraph
(b) or (c) of this section

    Although Eutaw argues that the lower portion of the excavation was rock, the exceptions

involving an excavation dug entirely in stable rock or less than 5 feet in depth do not apply in this
case.
1. Application of 29 C.F.R. § 1926.652(a)(1)
The requirements of § 1926.652(a)(1) are not in dispute. CO Schneider observed a number
of conditions that he considered unsafe with B & B’s protective system including a bent brace, trench
boxes not installed within two feet of the bottom of the excavation, and the gaps between the
excavation walls and boxes (Exh. C-1). He also observed seeping water, standing water, “severe”
erosion, and fissures (Tr. 32, 37, 86). He opined that it was a “very unstable excavation wall” (Tr.
59).
Although other standards may be applicable to the conditions alleged in the citation, the
general requirements of § 1926.652(a)(1) are appropriate to the B & B excavation. The hazard
addressed by the citation is the inadequacy of the overall protective system in providing cave-in
protection for B & B’s employees.
2. B & B’s Protective System Failed To Comply With § 1926.652(a)(1)
There is no dispute the excavation was approximately 14 feet deep, 45 feet long, and 18 feet
wide. The Geotechnical Report, which was performed by the City of Dothan, showed a “silty” sand
type material with rock at the 23 foot depth (Exh. R-7; Tr. 159, 198). At bore pit #3 in issue, B & B
received a change order because of rock at the 8-foot depth which made the boring operation under
the highway more costly. Instead of pushing the casing under the highway by hydraulic jacks, B&B
had to switch to actual hand excavation with jackhammers and shovels (Exh. R-8; Tr. 160-162, 206).
To perform the boring operation under the highway, B & B dug the 14-foot deep excavation
and installed two 8 x 24-foot trench boxes with steel shields behind the boxes. The trench boxes
were placed 4 to 6 feet from the bottom of the excavation. A 6-foot spreader bar on one trench box
was damaged. There were gaps between the two trench boxes and between the boxes and the shields
allowing erosion to fall inside the boxes (Exhs. C-1C, C-1K). CO Schneider observed “severe”
erosion and fissures in the excavation’s walls. There was also seeping water accumulating in the
bottom of the excavation. CO Schneider opined that the water accumulation could weaken the walls
and cause a cave-in (Tr. Tr. 31, 37).
The excavation was dug in Type C soil, the least stable soil. Significant erosion was present
underneath and behind the trench boxes and metal shields. In some areas, the trench box appeared
unsupported from the bottom. Erosion or soil migration was exacerbated by water seeping in and
accumulating in the excavation. The excavation, according to CO Schneider, was very unstable
which had started to cave-in and could have blown out at any time (Tr. 59).
Eutaw argues that although classified as Type C soil, the excavation consisted of a layer of
rock in the bottom eight feet. Eutaw asserts that as a layered excavation with more stable rock below
the Type C soil, the layers should be classified separately (Exh. R-1; Tr. 77). Eutaw cites 29 C.F.R.
Subpart P, Appendix A, section (c)(4) and OSHA Technical Manual, Section V, Chapter 2 (Exhs. R-
1, R-2).
The two soil samples taken from the spoil pile show Type C soil were consistent with the
City of Dothan’s Geotechnical Report. As explained by CO Schneider, the samples were taken near
the top of the spoil pile and thus an inference could be drawn that the samples represent the soil near
the bottom of the excavation (Tr. 68-69). CO Schneider’s visual observations of the soil erosion,
fissures, and seeping water at the excavation site show the lack of solid rock below the 8-foot level.
Eutaw performed no independent soil analysis of the excavation site.
Eutaw’s argument that the change order obtained by B & B establishes the presence of rock is
misplaced. The change order was due to the rock under Highway 84 which prevented B & B from
using the hydraulic jacks to force the core. The change order does not show that the excavation dug
to perform the boring operation also had rock at the 8-foot level.
The same layered contention was raised by B & B in its hearing before Judge Calhoun (No.
11-0466, June 27, 2011). According to her decision, the rock layers were sporadic or patchy, “there
was a 3 ft. patch here, a 2 ft. patch there, it was not consistent.” Judge Calhoun concluded that the
layered system must be classified in accordance with the weakest layer, in this case Type C, as
required by Appendix A of subpart P of Part 1926. This court agrees with Judge Calhoun.
Also, B & B’s protective system at issue was abated by Eutaw by lowering the trench boxes,
filling in the gaps, and slopping the top of the excavation wall away from the trench boxes (Tr. 60-
61). Eutaw made no showing that such abatement was prevented by rock.
Eutaw’s project superintendent Allen agreed the protective system was inadequate. Mr.
Allen testified that “I would have felt it was unsafe, and I needed to protect my employees” (Tr. 143).
If it was Eutaw’s excavation, he testified that he would have stopped the work and immediately
corrected the conditions (Tr. 142). In his interview statement, Mr. Allen acknowledged that he had
18 years of trenching experience; was the competent trenching person on site; and knew the location
of a trench box more than two feet above the bottom of the excavation violated an OSHA standard
(Exh. C-2).
The inadequacy of the protective system and the concerns regarding instability of the soil
conditions exposed B & B employees working in the excavation to possible cave-in. The excavation
had been open for approximately two months and approximately four B & B employees had worded
in the excavation. On the day of OSHA’s inspection, two B & B employees were in the excavation
performing the boring operation (Tr. 36, 80).
The record establishes noncompliance with § 1926.652(a)(1), employees’ exposure to the
conditions, and Superintendent Allen’s knowledge of the unsafe conditions. The excavation was in
plain view. Mr. Allen admitted that he inspected B & B’s work two to three times a week for
approximately 30 minutes each inspection (Tr. 127). If Eutaw is found to have sufficient authority
and control to prevent or abate the unsafe conditions under the multi-employer work site doctrine,
Eutaw’s violation of § 1926.652(a)(1) is established.
3. Multi-Employer Worksite Doctrine
Eutaw stipulates that it was the controlling employer of the worksite (Tr. 8). Its subcontract
agreement required B & B to follow all of Eutaw’s rules, policies, procedures and practices
pertaining to safety and health in the workplace “to the extent not inconsistent with and/or to the
extent more comprehensive or stringent than required by applicable law” (Exh. R-6, ¶ 14). Although
Eutaw generally subcontracts boring operations, it has significant excavation experience and
knowledge of OSHA’s excavation requirements. Underground utility work is its primary business
(Tr. 137, 146).
Under the multi-employer worksite doctrine, an employer including a general contractor who
controls or creates a worksite safety hazard may be liable for violations of the Occupational Safety
and Health Act (Act) even if the employees exposed to the hazard are solely employees of another
employer. A general contractor may be held responsible on a construction site to ensure a
subcontractor’s compliance with safety standards such as cave-in protection requirements if it is
shown that the general contractor could reasonably be expected to prevent or detect and abate the
violative condition by reason of its supervisory capacity and control over the worksite. Centex-
Rooney Construction Co., 16 BNA OSHC 2127, 2129-2130 (No. 92-0851, 1994). Also, see
OSHA’s Directive CPL 2-0.124 (Multi-Employer Citation Policy) issued December 10, 1999. (Exh.
R-2). 2

2
  The Commission is not bound by OSHA’s directives. OSHA’s internal documents and interpretations do not have

the force and effect of law, and do not confer procedural or substantive rights or duties on individuals. Caterpillar, Inc.,
15 BNA OSHC 2153, 2173 (No. 87-0922, 1993).
As controlling employer, Eutaw had the authority to ensure its subcontractor dug a safe
excavation. Its subcontract agreement required B & B to comply with OSHA requirements. Eutaw
exercised control over the work site and B & B employees. Eutaw’s project superintendent Allen
testified that he “had the authority to stop B & B’s employees if they committed an unsafe act.” He
also had the authority to correct any hazards (Tr. 137-138). He acknowledged that he knew B & B’s
protective system was inadequate (Tr. 143). Although he took no steps to correct the conditions or
even bring the problems to B & B’s attention, Mr. Allen “shut down the work site,” roped off the
excavation, and repositioned the trench boxes after the OSHA inspection (Tr. 60, 145).
Eutaw’s violation of § 1926.652(a)(1) is established as the controlling employer.
Unpreventable Employee Misconduct
Eutaw claims that if a violation is found, the violation was the result of unpreventable
employee misconduct by its project superintendent Allen. Eutaw claims that its supervisors such as
Mr. Allen were trained on the multi-employer policy and that employees were disciplined for not
complying with the company rules.
In order to establish the affirmative defense of unpreventable employee misconduct, an
employer is required to show that it has (1) established work rules designed to prevent the violation,
(2) adequately communicated these rules to its employees, (3) taken steps to discover violations, and
(4) effectively enforced the rules when violations are discovered. American Sterilizer Co., 18 BNA
OSHC 1082, 1087 (No. 91-2494, 1997).
``When the alleged misconduct is that of a supervisory employee, the employer must also
establish that it took all feasible steps to prevent the accident, including adequate instruction and
supervision of its employee'' Archer-Western Contractors Ltd., 15 BNA OSHC 1013, 1016-1017
(No. 87-1067, 1991). The defense is more difficult to establish since it is the supervisors’ duty to
protect the safety of employees under his supervision. A supervisor’s involvement in the misconduct
is strong evidence that the employer’s safety program was lax. Consolidated Freightways Corp., 15
BNA OSHC 1317 (No. 86-351, 1991).
Project superintendent Allen acknowledges B & B’s protective system was inadequate and he
took no steps to correct it (Tr. 137-138). He testified that he was unaware of the company’s multi-
employer policy at the time of the OSHA inspection. Since the inspection, he now recalls training on
the multi-employer policy in the OSHA 30- and 10-hour courses (Exhs. R-12, R-13; Tr. 124, 138).
Such training was provided to Eutaw’s supervisors by a safety consultant hired by Eutaw (Exh. R-
15).
Eutaw’s employee misconduct defense is rejected. The record fails to show that Eutaw has a
specific rule concerning the superintendent’s responsibilities as a controlling employer for the safety
of employees under his authority. There is no multi-employer policy as part of Eutaw’s written
safety program or its accident prevention program (Exhs. R-9, R-10). The fact the multi-employer
policy was taught to supervisors during the OSHA 30-hour course or 10-hour course does not mean
Eutaw adopted the policy as part of its safety program and provided superintendents with guidance
on implementing the policy (Exhs. R-12, R-13). Mr. Allen acknowledged that he gained his
knowledge of the multi-employer doctrine “since the inspection at this particular site” (Tr. 140).
Also, there is no showing that Eutaw monitored for compliance or disciplined for
noncompliance. Eutaw safety audits of worksites were not shown to include monitoring for
subcontractor’s safety compliance except for an audit after the OSHA inspection (Exh. R-11). Mr.
Allen received no discipline (verbal admonishment, written reprimand, demotion, or loss of pay) for
failing to comply with Eutaw’s alleged policy (Tr. 141, 190). There is no evidence of any
supervisors receiving discipline for not complying with the multi-employer policy.
Infeasibility Defense
Although Eutaw asserted an infeasibility defense at the hearing, it did not argue the defense in
its brief. 3 Nevertheless, the record fails to support an infeasibility defense. To establish the
affirmative defense, an employer must show that (1) the means of compliance prescribed by the
applicable standard would have been infeasible, in that (a) its implementation would have been
technologically or economically infeasible, or (b) necessary work operations would have been
technologically infeasible after its implementation, and (2) there would have been no feasible
alternative means of protection. V.I.P Structrues, Inc., 16 BNA OSHC 1873, 1874 (No. 91-1167,
1994).

3
Issues not briefed are deemed waived. See Georgia-Pacific Corp., 15 BNA OSHC 1127 (No. 89-2713, 1991).
Eutaw’s defense is based on B & B’s claim of rock at the 8-foot depth which allegedly
prevented the trench boxes from being installed within two feet of the bottom. However, Eutaw
presented no evidence that either it or B & B considered alternate methods for providing cave-in
protection. Adequate protective systems recognized by § 1926.652 include sloping, benching, support
systems, shield systems, and other protective systems. After the OSHA inspection, Eutaw lowered the
trench boxes (Tr. 60-61).
Serious Classification
Eutaw’s violation of § 1926.652(a)(1) was properly classified as serious. In order to establish
that a violation is serious under § 17(k) of the Act, the Secretary must show that there is a substantial
probability of death or serious physical harm that could result from the cited condition and the
employer knew or should have known of the violation. The likelihood of an accident is not required.
Spancrete Northeast, Inc., 15 BNA OSHC 1020, 1024 (No. 86-521, 1991).
Project superintendent Allen knew B & B’s protective system was inadequate based on the
positioning of the trench boxes more than two feet above the bottom of the excavation, the gaps
between the boxes and between the boxes and the excavation walls, and a bent cross bar. The
instability of the Type C soil was aggravated by the seeping water, standing water, and severe erosion
and fissures. B & B employees were exposed to a cave-in hazard as a result of the inadequate
protective system which could have resulted in death or serious injury.
Penalty Consideration
In determining an appropriate penalty, the Act requires consideration of the size of the
employer’s business, history of the employer’s previous violations, the employer’s good faith, and
the gravity of the violation. Gravity is the principal factor.
Eutaw has approximately 300 employees and is not entitled to credit for size (Tr. 145).
Twelve Eutaw employees worked on the sewer line project but none of them were exposed to the
inadequate protective system. Eutaw has a history of past serious citations within five years (Tr. 61).
Eutaw is entitled to credit for good faith based on its safety programs which consist of written rules,
training, and safety audits of projects (Exhs. R-9, R-10, R-11). Eutaw also has a progressive
disciplinary program (Exh. R-14).
A penalty of $ 2,500 is reasonable for Eutaw’s violation of § 1926.652(a)(1). B & B had
been working at the bore site for two months. There were approximately five B & B employees
exposed. Project Superintendent Allen was aware of the unsafe condition of the protective system
but failed to take any steps to correct the condition or even bring it to B&B’s attention.
FINDINGS OF FACT AND
CONCLUSIONS OF LAW

    The foregoing decision constitutes the findings of fact and conclusions of law in accordance

with Rule 52(a) of the Federal Rules of Civil Procedure.
ORDER
Based upon the foregoing decision, it is ORDERED:
1. Serious violation of § 1926.652(a)(1) is affirmed and penalty of $ 2,500 is assessed.

                                                            /s/ Ken S. Welsch
                                                          __________________________
                                                          KEN S. WELSCH
                                                          Administrative Law Judge

Date: September 27, 2011