OSHRC Commission decision Docket 08-1037 Decided November 20, 2009 Remanded

Nuprecon LP dba Nuprecon Acquisition LP

Fall-protection citation remanded

Apply this precedent to your situation

This is citable Commission precedent from 2009, and it may have been appealed since. Ezel checks how it stands today and answers your situation, with citations.

Currency note: this decision dates from 2009
The OSHA standards may have been amended, penalty amounts have been adjusted, and later Commission or court decisions may have changed the analysis since then. Treat this page as historical context, not current compliance advice. Verify the current standard before relying on any specific rule, threshold, or penalty mentioned here.
Decision of the Commission
This is a decision of the Occupational Safety and Health Review Commission, the highest level of agency review, citable as Commission precedent. It may have been appealed to a U.S. Court of Appeals after issuance; check subsequent history before relying on it. The full text below is from the official OSHRC release.
About this page: The plain-English summary and decision snapshot below were written by Ezel based on the official OSHRC release. The full text is the Commission's own document.
Read the official release (oshrc.gov)

Plain-English summary

Nuprecon employees used a Bobcat to push demolition debris through a 21-foot-wide open edge about 36.5 feet above a lower level. OSHA cited the company for inadequate fall protection and failure to retrain employees. The judge vacated both items, ruling on his own that the work was demolition rather than construction and that demolition standards might displace the cited fall-protection standard. The Commission held that the judge improperly amended the pleadings because neither party consented to try that issue and the change prejudiced the Secretary. It also held that the demolition provisions for floor openings and wall openings did not apply to this floor-to-ceiling unprotected edge and therefore did not preempt the cited standard. The Commission reversed the fall-protection vacatur as to applicability and remanded for findings on the remaining elements of that violation.

Decision snapshot

  • Cited standard(s): 29 C.F.R. § 1926.501(b)(1); 29 C.F.R. § 1926.503(c)
  • Outcome: Fall-protection vacatur reversed on applicability and remanded for further proceedings.
  • Key point: A judge cannot recast an admitted construction-work issue without the parties' consent when the change prejudices a party, and inapplicable demolition provisions do not preempt an unprotected-edge standard.

Full text (OSHRC public release)

NUPRECON LP dba NUPRECON ACQUISITION LP,., Docket No. 08-1037

SECRETARY OF LABOR,

Complainant,

v.

OSHRC Docket No. 08-1037

NUPRECON LP dba NUPRECON
ACQUISITION LP,

Respondent.

APPEARANCES:

Gary K. Stearman, Attorney; Charles F. James, Counsel for Appellate Litigation; Joseph M.
Woodward, Associate Solicitor of Labor for Occupational Safety and Health; Carol A. De Deo,
Deputy Solicitor of Labor for National Operations; U.S. Department of Labor, Washington, DC

For the Complainant

Aaron K. Owada, Esq.; AMS Law, P.C., Lacey, WA

For the Respondent

DECISION AND REMAND ORDER

Before: ROGERS, Chairman; THOMPSON, Commissioner.

BY THE COMMISSION:

STATEMENT OF THE CASE

On April 21, 2008, the Occupational Safety and Health Administration (“OSHA”)
conducted a programmed inspection of the Whidbey Island Naval Air Station in Oak Harbor,
Washington. Employees of Nuprecon LP (“Nuprecon”), a demolition contractor, were assigned
to demolish two hangar bays, two floors of another hangar, and a tunnel at the Naval Air Station.
As a result of the inspection, OSHA issued Nuprecon a citation alleging serious violations of two
provisions of the construction standard, proposing a penalty of $1,875. Specifically, OSHA
alleged that Nuprecon violated 29 C.F.R. § 1926.501(b)(1) by failing to protect its employees
from a fall hazard, and 29 C.F.R. § 1926.503(c) by failing to retrain its employees to understand
and use fall protection.

Following a hearing, Administrative Law Judge Benjamin R. Loye issued a decision in
which he essentially amended the pleadings to change the description of Nuprecon’s work at the
Naval Air Station from “construction” to “demolition” based on his finding that the parties
introduced “repeated and undisputed evidence . . . which unequivocally established that
[Nuprecon] was engaged only in demolition work at this site.” Alternatively, he found that
§ 1926.501(b)(1) was “preempted” by “one or both” of two “more specific demolition
standards,” which he stated “might apply more specifically to the conditions at issue here.” As a
result, the judge vacated the alleged fall protection violation

based on the Secretary’s failure to
establish applicability of the cited standard.

For the following reasons, we reverse the judge’s decision and remand the case to the
judge for further proceedings.

ISSUES

At issue on review are two separate but interrelated sua sponte actions taken by the
judge. First is the judge’s decision to effectively amend Nuprecon’s Answer. Second is his
finding that one or both of two provisions under the demolition standard preempted the cited fall
protection provision.

FINDINGS OF FACT

At the time of the inspection, Nuprecon’s employees were working on the third floor of
Hangar 5. On that floor, the OSHA compliance officer (“CO”) observed a twenty-one-foot long,
floor-to-ceiling open edge that Nuprecon used for pushing debris off its workspace to a lower
level of the hangar, approximately thirty-six-and-a-half feet below. Nuprecon had secured
across the opening a 5/8-inch thick cable, hung several feet above the floor, to prevent the
Bobcat vehicle (“Bobcat”) employees used to move debris from falling over the edge. Nuprecon
had also hung red plastic warning tape several feet above the floor from the walls near the open
edge to and between stanchions standing in the passageway, creating a rectangular area in front
of the open edge.

DISCUSSION

I. AMENDMENT TO THE PLEADING

PRINCIPLES OF LAW

Federal Rule of Civil Procedure 15(b) governs the amendment of pleadings in
Commission proceedings .

NORDAM Group , 19 BNA OSHC 1413, 1414, 2001 CCH OSHD
¶ 32,365, p. 49,684 (No. 99-0954, 2001), aff’d , 37 F. App’x 959 (10th Cir. 2002) (unpublished);
see also Reed Eng’g Group, Inc. , 21 BNA OSHC 1290, 1291, 2005 CCH OSHD ¶ 32,862,
p. 53,087 (No. 02-0620, 2005) (abuse of discretion standard of review for judge’s decision to
amend a pleading). The Commission has stated that amendment under the provision now
designated Rule 15(b)(2) “is proper only if two findings can be made—that the parties tried an
unpleaded issue and that they consented to do so.” McWilliams Forge Co. , 11 BNA OSHC
2128, 2129, 1984-85 CCH OSHD ¶ 26,979, p. 34,669 (No. 80-5868, 1984). “Consent will be
found only when the parties ‘squarely recognized’ that they were trying an unpleaded issue.”
NORDAM Group , 19 BNA OSHC at 1414, 2001 CCH OSHD at p. 49,684 (citing Armour Food
Co. , 14 BNA OSHC 1817, 1824, 1987-90 CCH OSHD ¶ 29,088, p. 38,885 (No. 86-247, 1990)).
“Conversely, consent is not implied by a party’s failure to object to evidence that is relevant to
both pleaded and unpleaded issues, at least in the absence of some obvious attempt to raise the
unpleaded issue.” McWilliams Forge Co. , 11 BNA OSHC at 2130, 1984-85 CCH OSHD at p.
34,699.

Under the provision now designated Rule 15(b)(1), the Commission has stated that
“[e]ven if a party objects to the use of evidence in support of an unpleaded charge, the pleadings
may be amended . . . if the objecting party does not suffer prejudice.” NORDAM Group ,
19 BNA OSHC at 1414, 2001 CCH OSHD at p. 49,684 (citing Morrison-Knudsen Co./Yonkers
Contracting Co. , 16 BNA OSHC 1105, 1113, 1993-95 CCH OSHD ¶ 30,048, pp. 41,269-70 (No.
88-572, 1993)). “To determine whether a party has suffered prejudice, it is proper to look at
whether the party had a fair opportunity to defend and whether it could have offered any
additional evidence if the case were retried.” ConAgra Flour Milling Co. , 15 BNA OSHC 1817,
1822, 1991-93 CCH OSHD ¶ 29,808, p. 40,592 (No. 88-2572, 1992).

ANALYSIS

Nuprecon explicitly admitted in its Answer that it was “engaged in the business of
construction” at the worksite. Nuprecon, who has been represented by counsel throughout these
proceedings, now claims its admission was a “mistake” that occurred “because it was unaware
that OSHA standards made a distinction between ‘demolition’ and ‘construction.’” Thus, it
agrees with the judge’s decision to sua sponte amend the pleadings because, it claims, the
Secretary impliedly consented to try whether Nuprecon was engaged in demolition or
construction.

Based on our review of the record, we find that neither party explicitly or impliedly
consented to try the issue raised by the judge’s amendment. McWilliams Forge Co. , 11 BNA
OSHC at 2130, 1984-85 CCH OSHD at p. 34,669. Neither party’s post-hearing brief addressed
this issue; in fact, the Secretary’s brief declared that “[i]t is undisputed that . . . [Nuprecon] was
engaged in the business of construction.” And as the Secretary notes, “Nuprecon’s defense
throughout was that it complied with the cited construction standard,” not that the cited standard
was inapplicable.

Absent some indication that Nuprecon learned of its “mistake” before the judge’s
decision issued, it could not have consented to the judge’s line of reasoning about the nature of
the company’s work. Moreover, the Secretary could not have consented to try the issue when
she lacked notice that the judge considered applicability to still be in dispute despite Nuprecon’s
conclusive admission. Indeed, we are not persuaded that references to demolition during the
proceedings and in the Secretary’s post-hearing brief, as relied upon here by the judge,
decisively support his conclusion that the parties “agreed . . . [Nuprecon] was engaged solely in
demolition work.” None of these passing references, which consist largely of statements
describing the nature of Nuprecon’s work as demolition, would have put either party on notice
that there remained any dispute over whether the company was engaged in construction at the
Naval Air Station or that the cited standard applied here. See NORDAM Group , 19 BNA OSHC
at 1414, 2001 CCH OSHD at p. 49,684 (finding consent only where parties “squarely
recognized” trying the unpleaded issue). Furthermore, the record contains references by the
Secretary and Nuprecon that describe both the project and Nuprecon’s work as construction,
none of which were addressed by the judge.

We also find that the Secretary was prejudiced by the judge’s amendment. As the
Secretary notes, had she “been fairly apprised of the issue, she would have adduced evidence
detailing the scope of the Hangar 5 renovation and Nuprecon’s role in it” including Nuprecon’s
subcontract for the provision of construction services. Thus, the Secretary points to specific
evidence she would have used to establish that Nuprecon’s work was construction. Cf.
ConAgra , 15 BNA OSHC at 1822, 1991-93 CCH OSHD at p. 40,592 (finding lack of prejudice
where employer “pointed to no evidence that it would have introduced and makes no specific
allegations to support its claim”).

Under these circumstances, we find the judge abused his discretion in amending the
pleadings sua sponte . Therefore, we find that Nuprecon’s admission establishes that the work it
performed at the Naval Air Station was construction work covered by Part 1926 and Subpart M -
Fall Protection.

II. PREEMPTION

PRINCIPLES OF LAW

Section 1910.5(c)(1) governs which standard or standards apply to a specific work
practice or condition. Cincinnati Gas & Elec. Co. , 21 BNA OSHC 1057, 1058, 2005 CCH
OSHD ¶ 32,836, p. 52,771 (No. 01-0711, 2005); Lowe Constr. Co. , 13 BNA OSHC 2182, 2183,
1987-90 CCH OSHD ¶ 28,509, p. 37,796 (No. 85-1388, 1989). It provides that “[i]f a particular
standard is specifically applicable to a condition, practice, means, method, operation, or process,
it shall prevail over any different general standard which might otherwise be applicable . . . .”
29 C.F.R. § 1910.5(c)(1). But “[a] general standard is not preempted by a specific standard
when it provides meaningful protection to employees beyond that afforded by the more specific
standard.” Cincinnati Gas & Elec. , 21 BNA OSHC at 1058, 2005 CCH OSHD at p. 52,771.

ANALYSIS

The cited standard, a provision in Subpart M - Fall Protection of Part 1926, provides as
follows:

Each employee on a walking/working surface (horizontal and vertical surface)
with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower
level shall be protected from falling by the use of guardrail systems, safety net
systems, or personal fall arrest systems.

29 C.F.R. § 1926.501(b)(1). The judge found that this standard was preempted “by one or both”
of two standards within Subpart T - Demolition of Part 1926: 29 C.F.R. § 1926.856(b) and
29 C.F.R § 1926.850(g).

We find that neither of these demolition standards apply to the hazardous condition and
therefore do not preempt § 1926.501(b)(1). The first standard, § 1926.856(b), requires that floor
openings “have curbs or stop-logs to prevent equipment from running over the edge.” Here,
there was no floor opening as described in the demolition standard: “[a]ny openings cut in a
floor for the disposal of materials . . . .” 29 C.F.R. § 1926.853. Instead, Nuprecon’s work area
contained an unprotected, twenty-one-foot long, floor-to-ceiling edge. Section 1926.501(b)(1),
the cited standard, specifically applies to such “[u]nprotected sides and edges.”

The other demolition standard identified by the judge, § 1926.850(g), requires employers
to protect employees exposed to the hazard of falling through a “wall opening,” which presumes
the existence of a wall.

Here, there was no wall, only a floor with no side and an unprotected
twenty-one-foot long floor-to-ceiling edge. Section 1926.501(b)(1), clearly applies to such “an
unprotected side or edge.” And it requires fall protection consistent with the complete absence
of a wall—“guardrail systems, safety net systems, or personal fall arrest systems.” Thus, these
standards complement each other by covering different types of fall hazards. See OSHA
Construction Resource Manual, Overview for Subpart T - Demolition, T-2B,
http://www.osha.gov/Publications/Const_Res_Man/index.html (last visited Nov. 20, 2009)
(noting in overview of the demolition subpart that the requirements of the fall protection subpart
“will provide further clarification of what measures are necessary to assure employees are
protected from falling”); see also McNally Constr. & Tunneling Co. , 16 BNA OSHC 1879,
1882, 1993-95 CCH OSHD ¶ 30,506, p. 42,167 (No. 90-2337, 1994) (stating that “general safety
standards can complement specific standards by filling in the interstices necessarily remaining
after the promulgation of the specific standards”), aff’d , 71 F.3d 208 (6th Cir. 1995).

Given that neither demolition standard applies to the cited condition, we find the judge
erred in concluding that one or both of these standards preempted the cited fall protection
standard.

CONCLUSIONS OF LAW

Because the judge amended the pleadings to designate Nuprecon’s work as demolition
rather than construction without the parties’ consent and with prejudice to the Secretary, we
conclude that he abused his discretion. Additionally, we conclude the judge erred in finding that
two demolition standard provisions preempted the cited fall protection standard. Therefore, we
reverse the judge’s vacatur, find the Secretary established the cited standard’s applicability, and
remand the case to the judge to consider whether the Secretary established the remaining
elements of the violation alleged under § 1926.501(b)(1).

SO ORDERED.

/s/                                                                     

Thomasina V. Rogers

Chairman

/s/                                                                     

Horace A. Thompson III

Commissioner

Dated: 11/20/2009

Secretary of Labor,

Complainant,

v.

OSHRC DOCKET NO. 08-1037

Nuprecon, LP,

Respondent.

Appearances:

Abigail G. Daquiz, Esq., Office of the Solicitor, U.S. Department of Labor, Seattle, Washington

For Complainant

Aaron K. Owada, Esq., AMS Law, P.C., Lacey, Washington

For Respondent

Before:   Administrative Law Judge Benjamin R. Loye

DECISION AND ORDER

Procedural History This proceeding is before the Occupational Safety and Health Review Commission ("the Commission") pursuant to Section 10(c) of the Occupational Safety and Health Act of 1970, 29 U.S.C. §651
et seq . ("the Act"). The Occupational Safety and Health Administration ("OSHA") conducted an inspection of a Nuprecon, LP ("Respondent") worksite at a naval air station near Seattle, Washington on
April 21, 2008. As a result of the inspection, OSHA issued a Citation and Notification of Penalty to
Respondent alleging two violations of the Act. Citation 1 Item 1(a) alleges a serious violation of 29
C.F.R. §1926.501(b)(1). Citation 1 Item 1(b) alleges a serious violation of 29 C.F.R. §1926.503(c). A
grouped penalty totaling $1,875 was proposed for both violations. Respondent timely contested the
citation and an administrative trial was held on March 11, 2009, in Seattle, Washington. Both parties
have filed post-trial briefs and this case is ready for disposition.

Jurisdiction

The parties agree that jurisdiction of this action is conferred upon the Occupational Safety and
Health Review Commission pursuant to Section 10(c) of the Act. The parties also agree that at all
times relevant to this action, Respondent was an employer engaged in a business affecting interstate
commerce within the meaning of Section 3(5) of the Act, 29 U.S.C. §652(5). (Complaint and Answer).

Factual Findings On April 21, 2008, OSHA Compliance Safety and Health Officer Kalah Goodman conducted an
inspection of work activities at Whidbey Island Naval Air Station in Washington. (Tr. 14). The inspection was a programmed planned inspection of the site as a result of the location being listed on OSHA's
Dodge Report. (Tr. 14). Respondent was one of the employers working on site that day. At the time of
the inspection, Respondent had employees working on the third and fourth floors of Hangar Five. (Tr.
17, 26, 72). Respondent is a demolition contractor and does not perform any other type of work. (Tr.
72). Its job at this worksite was to demolish two hangar bays, two floors of another hangar, and a tunnel. (Tr. 73).

CSHO Goodman entered the third floor of Hangar Five and observed a 21-foot horizontal opening at one outer edge of the floor. (Tr. 20, 60; Ex. 2, 5). The floor opening had a 5/8-inch thick wire
cable stretched across it, which was secured to the two columns on either side. (Tr. 20, 40, 74; Ex. 2, 4).
There was also red plastic tape surrounding the floor opening in a rectangular pattern, approximately 15
feet from the edge. (Tr. 79-80). The distance from the edge of the third floor opening to the ground
below was approximately 36 feet. (Tr. 75-76; Ex. 5).  

CSHO Goodman learned that the 21-foot opening was being used by a Nuprecon employee operating a Bobcat front-end loader to push debris off the edge as part of the building demolition. (Tr.
25). However, at the time of her inspection, the Bobcat operator was not working near the edge. (Tr.
25, 43-44). He was working in an adjacent area of the third floor, piling up piping which was being
removed from the building. (Tr. 25). CSHO Goodman observed another Nuprecon employee working
near the red tape barrier, but outside its boundaries, on a scissor lift. (Tr. 25, 29, 47; Ex. 4). There were
also several Nuprecon employees who passed through the third floor of Hangar Five daily on their way
up to the fourth floor. (Tr. 26, 47).

CSHO Goodman testified that the regulations, under these circumstances, provided for only
three methods of acceptable fall protection for employees accessing the third floor: guardrail systems,
safety net systems, or personal fall arrest systems. (Tr. 26, 28). She testified that the use of a wire rope
and red tape to guard this open floor edge was not sufficient. (Tr. 26-29). The Secretary considered all
employees working on the third floor of Hangar Five to be exposed to a fall hazard as a result of this
condition. (Tr. 46, 48-49; Complainant's Post-Hearing Brief, p.6). The parties agree that a 36-foot fall
would unquestionably result in serious injury or death. (Tr. 34, 115).

During the inspection, CSHO Goodman observed and video-taped the floor opening while
standing just outside the red tape boundary. (Tr. 39). Although she testified that any employee who
walked on the third floor was exposed to a fall hazard as a result of this condition, she did not consider
herself personally exposed to the fall hazard while standing fifteen feet from the edge. (Tr. 39). She
acknowledged that the red tape surrounding the edge indicated to her that she should stay out of that
area. (Tr. 40). She further acknowledged that she never saw any employees working within the
boundaries of the red tape. (Tr. 43).

Prior to the inspection, Respondent had implemented and trained its employees on a color-coded system regarding plastic tape boundaries. (Tr. 77). Red tape is recognized as the highest danger
level and employees are trained to stay out of any area demarcated with red tape. (Tr. 77). The lone
exception in this instance was the Bobcat operator, who actually maneuvered his machine inside the
area so that debris could be pushed off the floor opening to the ground below. (Tr. 76, 80, 83-84, 95).

Respondent presented evidence and argument on a multitude of alternative fall protection
methods identified in the regulations. However, Aaron Tomaras, Respondent's Superintendent on the
day of the inspection, conceded that the wire rope stretched across the opening did not constitute a
guard rail system, that the Bobcat operator's use of a seat belt did not constitute fall protection, that the
floor opening was not a leading edge, and that "warning line system" referenced in §1926.500 applies
only to roof work. (Tr. 88, 90-91, 115). He also conceded that this location was not a roof. (Tr. 91).
Avery Brown, Respondent's Field Safety Officer, maintained that the red-taped area surrounding the
third floor opening was a "controlled access zone." (Tr. 101-102). However, I find that Respondent
was not engaged in the type of activities referenced by the controlled access zone regulation [29 C.F.R.
§1926.502(g)]: bricklaying, leading edge work, precast concrete erection work, or residential
construction.  

As a result of her observations during the inspection, CSHO Goodman recommended the two
violations at issue in this case. Citation 1 Item 1(a) alleges that Respondent failed to implement an
acceptable fall protection system at the 21-foot opening in the demolition area on the third floor of
Hangar Five. (Tr. 26; Ex. 7). Citation 1 Item 1(b) alleges that Respondent failed to re-train employees
on fall protection requirements. (Tr. 37-38; Ex.7). CSHO Goodman testified that the re-training
violation was based only on the existence of the fall protection violation and that she would not have
recommended it otherwise. (Tr. 49). In calculating the proposed $1,875 penalty, CSHO Goodman
concluded there was a high severity of injury, but a low probability of an actual accident. (Tr. 35). She
also applied a 15% penalty reduction for the Respondent's good faith during the inspection, and an
additional 10% reduction for Respondent's lack of violations in the past three years. (Tr. 36).

Discussion

To establish a prima facie violation of the Act, the Secretary must prove: (1) the standard applies
to the cited condition; (2) the terms of the standard were violated; (3) one or more of the employer’s
employees had access to the cited condition; and (4) the employer knew, or with the exercise of
reasonable diligence could have known, of the violative condition. Ormet Corporation , 14 BNA OSHC
2134, 1991 CCH OSHD ¶29,254 (No. 85-0531, 1991).

Citation 1 Item 1(a)

The Secretary alleges in Citation 1 Item 1(a) that:

29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an              unprotected side or edge which was 6 feet (1.8 m) or more above a lower level
was not protected from falling by the use of guardrail systems, safety net systems, or              personal fall arrest systems:

(a) Third Floor Loading Zone, where the demolition work area and passageway
were     located adjacent to an unguarded open sided floor located 36½ feet above the              lower level. Hazard: Fall from elevation.

The cited standard provides:

Unprotected sides and edges. Each employee on a walking/working surface              (horizontal and vertical surface) with an unprotected side or edge which is 6
feet       (1.8 m) or more above a lower level shall be protected from falling by the use of
             guardrail systems, safety net systems, or personal fall arrest systems.         

The first issue that must be addressed is whether or not the cited standard applies. The Secretary
asserts in her post-trial brief that "[t]his standard applied to construction workplaces, setting forth
requirements and criteria for fall protection." The Secretary further states that "Respondent does not
dispute that it was engaged in construction activities at the worksite on the day of the inspection." A
review of Respondent's Answer, specifically in its response to Paragraph II of the Secretary's Complaint,
supports that assertion.

The record, however, overwhelmingly establishes that Respondent was engaged only in
demolition work at this site. (Tr. 7:22, 17:24, 18:15, 72-73; Ex. 1, p.4; Complainant's Post-Hearing
Brief, pp. 7, 18). Even the language of the citation itself alleges that this was "a demolition work area."
(Ex. 7). Counsel for the parties and every testifying witness agreed on that fact throughout the trial.
Respondent further established that it is exclusively a demolition contractor and performs no other type
of work. (Tr. 72-73). Although Paragraph II of the Secretary's Complaint contains the word
"construction", its primary focus is Respondent's engagement in a business affecting interstate
commerce. It would be improper to ignore repeated and undisputed evidence, introduced by both
parties during trial, which unequivocally established that Respondent was engaged only in demolition
work at this site.

F.R.C.P. 15(b) allows pleadings to be amended to conform to the evidence presented at trial.
The rule is "designed to facilitate the amendment of pleadings except where prejudice to the opposing
party would result." U.S. v. Hougham , 364 U.S. 310, 316 (1960). "The federal rules reject the approach
that pleading is a game of skill in which one misstep by counsel may be decisive to the outcome and
accept the principle that the purpose of pleading is to facilitate a proper decision on the merits." Id .
Since the parties and witnesses all agreed that Respondent was engaged solely in demolition work, the
Secretary will not be prejudiced by such a factual finding. Therefore, pursuant to F.R.C.P. 15(b), I find
that Respondent was not engaged in construction work. Respondent was engaged in demolition work at
this site.

29 C.F.R. §1926.500(a)(1) specifically defines the scope and application of the fall protection
regulations applied to Respondent in this case. It provides that "[t]his subpart sets forth requirements
and criteria for fall protection in construction workplaces covered under 29 CFR Part 1926" (emphasis
added). The term "construction work" is defined as "construction, alteration, and/or repair, including
painting and decorating." 29 C.F.R. §1926.32(g). Several unreviewed Commission Administrative Law
Judge decisions have recognized that the term "demolition" was not specifically included in the
definition of "construction", but held that demolition should be implicitly included because it involves
many of the same tools and equipment. Anderson Excavating & Wrecking , 16 BNA OSHC 1601 (Nos.
92-1899 & 2122, 1993); S.G. Loewendick and Sons , 6 BNA OSHC 1630, 1978 CCH OSHD ¶22,730
(No. 76-3064, 1978); see also Haynes & Mouw, Inc ., 11 BNA OSHC 1125, 1983-1984 CCH OSHD
¶26,394 (Nos. 82-374 & 350, 1983). I respectfully disagree. The plain meaning of the words included,
or excluded, by the Secretary in regulations should be controlling. Metwest, Inc ., 22 BNA OSHC 1066,
2008 CCH OSHD ¶32,942 (No. 04-0594, 2007). "Construction work" was defined by the Secretary in a
manner that did not include demolition. In further support of the distinction, the term "demolition" was
specifically added in other Part 1926 regulations, presumably to eliminate this problem in other
contexts. See 29 C.F.R. §1926.150(a) (fire protection standards encompassing both "construction" and
"demolition") ; §1926.1101(a) & (b) (asbestos standards specifying application to "construction" in one
subpart and "demolition" in another) ; and § 1926.62(a)(1) (lead standards specifying the inclusion of
"demolition" activities).

Furthermore, the Secretary promulgated Subpart T of Part 1926 to address safety requirements
for demolition work. Two of the demolition standards appear as if they might apply more specifically to
the conditions at issue here, although neither was raised during this proceeding:

29 C.F.R. §1926.856(b): Floor openings shall have curbs or stop-logs to prevent              equipment from running over the edge; and/or

29 C.F.R. §1926.850(g): Where a hazard exists to employees falling through wall              openings, the opening shall be protected to a height of approximately 42 inches.

I find that the Secretary failed to establish that the c onstruction standard in Citation 1 Item 1(a)
applied to Respondent's demolition activities on this site. Alternatively, I find that the cited general fall
protection standard is preempted in this instance by one or both of the more specific demolition
standards identified above. Lowe Construction Co. , 13 BNA OSHC 2182, 1989 CCH OSHD ¶28,509
(No. 85-1388, 1989); Bratton Corporation , 14 BNA OSHC 1893, 1990 CCH OSHD ¶29,152 (No. 83-0132, 1990). Since neither party addressed either of these demolition standards at trial, I find that it
would be prejudicial to both parties to amend Citation 1 Item 1(a), sua sponte , to allege a violation of
the above-listed demolition regulations. A.L. Baumgartner Const., Inc. , 16 BNA OSHC 1995 (No. 92-1022, 1994). Accordingly, Citation 1 Item 1(a) must be vacated.

Citation 1 Item 1(b)

The Secretary alleges in Citation 1 Item 1(b) that :

29 CFR 1926.503(c): The employer did not retrain affected employees who
already had been trained but demonstrated inadequate understanding and skill required
by paragraph (a) of this section:

(a) Third Floor Loading Zone, where the demolition work area and passageway
were     located adjacent to an unguarded open sided floor located 36½ feet above the
lower   level. Hazard: Fall from elevation.

The cited standard provides:

Retraining. When the employer has reason to believe that any affected employee              who has already been trained does not have the understanding and skill required
by         paragraph (a) of this section, the employer shall retrain each such employee.              Circumstances where retraining is required include, but are not limited to,
situations where:

(1) Changes in the workplace render previous training obsolete; or

(2) Changes in the types of fall protection systems or equipment to be used render
previous training obsolete; or

(3) Inadequacies in an effected employee's knowledge or use of fall protection
systems or equipment indicate that the employee has not retained the requisite
understanding or skill.

The Secretary offered no evidence in support of Citation 1 Item 1(b). The OSHA Compliance
Officer testified that the only reason she recommended the training citation item was because she
observed a fall hazard. Therefore, according to her, there must have been a failure to re-train employees
on fall protection. However, the mere existence of a violative condition does not, in and of itself,
establish that employees were not trained (or in this instance, not re-trained) on a particular subject.
N&N Contractors, Inc. , 18 BNA OSHC 2121, 2000 CCH OSHD ¶32,101 (No. 96-0606, 2000). The
Secretary failed to establish a violation of the cited regulation. Accordingly, Citation 1 Item 1(b) must
be vacated.

Affirmative Defenses

Respondent did not argue the merits of any affirmative defenses in its post-hearing brief.
Therefore, the affirmative defenses identified in Respondent's September 12, 2008 letter to the court are
deemed abandoned.

ORDER

Based upon the foregoing Findings of Fact and Conclusions of Law, it is ORDERED that:

1. Citation 1 Item 1(a) is VACATED; and

2. Citation 1 Item 1(b) is VACATED.

Date:     May 21, 2009                                                   /s/______

Denver, Colorado                                                         Benjamin R. Loye

Judge, OSHRC

Get today's answer for your situation

You just read Commission precedent from 2009. Ezel checks whether it still stands, including any court review since, and answers your specific situation, with citations.

Opens in Ezel Pro. Every answer cites the authority it relies on.